Ys- 9000c with External Paddles Defi-Monitor Defibrillator

China Ys-9000c with External Paddles Defi-Monitor Defibrillator, Find details about China External Defibrillator, Cardiac Defibrillator from Ys-9000c with External Paddles Defi-Monitor Defibrillator

Model NO.
YS-8000C YS-9000C
Main Unit
Portable
Dimensions
L320xw205xh410
Weight
9.5kg
Trademark
YSENMED
Transport Package
Carton
Origin
China
Model NO.
YS-8000C YS-9000C
Main Unit
Portable
Dimensions
L320xw205xh410
Weight
9.5kg
Trademark
YSENMED
Transport Package
Carton
Origin
China
Ys-9000c with External Paddles Defi-Monitor DefibrillatorYS-8000C Defi-Monitor
Physical characteristics:
Main unit: Portable
Dimensions:L320xW205xH410
Weight:9.5kg
Technical specifications   
DEFIBRILLATOR.
       (1)   Defibrillator type                 Manual, Synchronized, Asynchronized,    
       (2)   Out put waveform                Monophasic technology                                                                             
       (3)   Energy accuracy              ∠+1%
    (4)  Energy selection                   0,3,5,7,10,20,30,50,100,200,300,360 joule(normal at a resistance of 50)
       (5)   Charging time                   Maximum 8 seconds to 360 Joules
    (6)  Standard Adult/Pediatric Paddles   Reusable extermal adult paddles(pediatric paddles integrated)             
.Power requirements.
       (a)   AC Power supply                110V, 60 Hz /220V,50 Hz  
    (b) Vehicle Voltage             DC 12V
Internal Battery Backup
              (1)   Battery type              Rechargeable lead-acid battery/ lithium battery(optional)
              (2)   Charging time            Time-Minimum of 4 hours for full charging     
           (3)    Battery charging      During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication      Red LED                
(5) Battery Capacity        100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.
Display
-LED Dimensions  7'diagonal {155mm*88mm}
-Type                    High resolution true-color graphic LED
-Resolution           480X234
 
 
 
ECG
ECG lead: , , , AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protegtion: With stand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation

Respiration
Measurement method: Thoracic impedance
Standard parameter & configuration
 ECG/ RESP/DEFIBRILLATOR
Optional parameter
Recorder
 
Physical characteristics:
Main unit: Portable
Dimensions:L320xW205xH410
Weight:9.8kg
Technical specifications   
DEFIBRILLATOR.
 (1)   Defibrillator type                 Manual, Synchronized, Asynchronized,    
 (2)   Out put waveform                Monophasic technology                                                                             
 (3)   Energy accuracy                 ∠+1%
 (4)  Energy selection                   0,3,5,7,10,20,30,50,100,200,300,360 joule(normal at a resistance of 50)
 (5)   Charging time                   Maximum 8 seconds to 360 Joules
 (6)  Standard Adult/Pediatric Paddles   Reusable extermal adult paddles(pediatric paddles integrated)             
.Power requirements.
 (a)   AC Power supply                110V, 60 Hz /220V,50 Hz  
 (b) Vehicle Voltage                      DC 12V
Internal Battery Backup
(1)   Battery type              Rechargeable lead-acid battery/ lithium battery(optional)
(2)   Charging time            Time-Minimum of 4 hours for full charging     
(3)    Battery charging      During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication      Red LED                
(5) Battery Capacity        100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.
Display
-LED Dimensions  7'diagonal {155mm*88mm}
-Type             High resolution true-color graphic LED
-Resolution        480X234
 
 
 
ECG
ECG lead: , , , AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protegtion: With stand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation

Respiration
Measurement method: Thoracic impedance
NIBP
Working mode: Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cufftype: standard Adult; optional Pediatric/Neonatal

Temperature
Measurement range 20~45ºC
Resolution 0.1ºC
 
Pulse Oximetry(spO2)
Display :spo2 value,pulse histongram,waveform,Pulse
Range: 0~99%for adult,pediatric and neonatal patients
Probe :standard adult finger clip
optional pediatric Y-type clip and neonatal wrap
Pulse range
Pulse range: 0-255bpm

Standard parameter & configuration
 ECG/ RESP,/SPO2,/TEMP,/PR,/NIBP/DEFIBRILLATOR
Optional parameter
Recorder



 
Ys-9000c with External Paddles Defi-Monitor Defibrillator
Ys-9000c with External Paddles Defi-Monitor Defibrillator
Ys-9000c with External Paddles Defi-Monitor Defibrillator
Ys-9000c with External Paddles Defi-Monitor Defibrillator