Intensive Care Multipara ECG Heart Rate Patient Monitor with Etco2 and IBP Module

China Intensive Care Multipara ECG Heart Rate Patient Monitor with Etco2 and IBP Module, Find details about China ECG Heart Rate Patient Monitor, ECG Patient Monitor from Intensive Care Multipara ECG Heart Rate Patient Monitor with Etco2 and IBP Module

Model NO.
KD-PM001
Trademark
OEM, ODM
Transport Package
37*29*33.5cm
Specification
Standard Packing for Export
Origin
Guangdong China
HS Code
9018110000
Model NO.
KD-PM001
Trademark
OEM, ODM
Transport Package
37*29*33.5cm
Specification
Standard Packing for Export
Origin
Guangdong China
HS Code
9018110000
 
Intensive Care Multipara ECG Heart Rate Patient Monitor with Etco2 and IBP Module
Intensive Care Multipara ECG Heart Rate Patient Monitor with Etco2 and IBP Module

 

Portable patient monitor

12.1" color TFT screen 
Multi-channel display 
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms

Alarm review, arrhythmia review 
Patient info. Input 
Anti-defibrillation design
NIBP overpressure protection
Plug-in rechargeable battery, AC/DC available. 
Supporting wired or wireless network.

Technical Specifications for Portable patient monitor
b
Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection I, II, III, avR, avL, avF, V
Wavef orm 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL) 
Lead selection I, II, III,
Wave form 1 ch
Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range Adult 15 ~ 300 bpm
Neo/Ped 15 ~ 350 bpm
Accuracy ±1% or±1bpm, which is greater
Resolution 1 bpm 
Sensitivity > 200 (uVp-p) 
Differential Input Impedance > 5 MΩ

CMRR Monitor > 105 dB 
Operation > 105 dB 
Diagnosis > 85 dB
Electrode offset potential ±300mV 
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi. 
ECG Signal Range ±8 m V ( Vp-p )

Bandwidth Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
Calibration Signal 1 (mVp-p), Accuracy:5%
ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, BRADY, MISSED BEATS,
PNP, PNC, Alarm Available, Review Available

 

Respiration
Method Impedance between R-F(RA-LL)
Differential Input Impedance > 2.5 MΩ
Measuring Impedance Range 0.3~3 Ω
Baseline Impedance Range 200~4 KΩ
Bandwidth 0.1~2.5Hz
Resp. Rate Measuring and Alarm Range
Adult 0 ~ 120 Bram 
Neo/Ped 0 ~ 150 Bram 
Resolution 1 Bram 
Accuracy ±2 Bram

Apnea Alarm 10 ~ 40 S

NIBP
Method Oscillometric
Mode Manual, Auto, STAT 
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN

Measuring and alarm range Adult Mode
SYS 40 ~ 270 mmHg 
DIA 10 ~ 215 mmHg 

MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg 
DIA 10 ~ 150 mmHg 
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg 
DIA 10 ~ 100 mmHg 
MEAN 20 ~ 110 mmHg

Resolution 1mmHg
Accuracy Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection Adult Mode 297±3 mmHg 
Pediatric Mode 240±3 mmHg 
Neonatal Mode 147±3 mmHg


SpO2
Measuring Range 0 ~ 100 % 
Alarm Range 0 ~ 100 % 
Resolution 1 %
Accuracy 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization intervalabout 1 Sec. 
Alarm Delay 10 Sec.
Pulse Rate Measuring and Alarm Range 20~300 bpm
Resolution 1bpm
Accuracy ±3bpm

TEMP
Channel 2
Measuring and Alarm Range 0 ~ 50 ºC
Resolution 0.1 ºC
Accuracy ±0.2 ºC
Actualization intervalabout 1 Sec.
Average Time Constant < 10 Sec.


 

ECG

Lead mode

I,II,III,AVR,AVL,AVF,V

Gain

x0.25,x0.5,x1,x2

Heart Rate

15-300BPM(Adult)  15-350BPM(Neonatal)

Resolution

1BPM

Accuracy

±1%

ST measurement Range

-2.0-+2.0mV

Accuracy

±10%

Pacemaker

Yes

Sweep Speed

12.5mm/s,25mm/s,50mm/s

 

Bandwidth

 

 

Diagnostic: 0.05~130 Hz

Monitor:0.5 - 40 Hz

Surgery:1 ~ 20 Hz

 

SPO2

Measure range

0-100%

Resolution

1%

Accuracy

2% (70-100%)

Pulse Rate

20-250 BPM

Resolution

1BPM

Accuracy

±3BPM

 

NIBP

Work Mode

Manual, Automatic, continuous

Unit

mmHg,kPa

Measure range:

Adult

SYS: 40-280mmHg

DIA: 10-225mmHg

MEAN:20-240mmHg

Pediatric

SYS: 40-220mmHg

DIA: 10-160mmHg

MEAN:20-170mmHg

Neonatal

SYS: 40-135mmHg

DIA: 10-100mmHg

MEAN:20-110mmHg

Resolution

1mmHg

Accuracy

±5mmHgport upgrade via network

RESP

Measure range

0-150BrPM

Resolution

1 BIPM

Accuracy

±2%

 

TEMP

Measure range

0-50ºC

Resolution

0.1ºC

Accuracy

±0.1ºC

 

 
 About Our Company
 
Intensive Care Multipara ECG Heart Rate Patient Monitor with Etco2 and IBP Module
Intensive Care Multipara ECG Heart Rate Patient Monitor with Etco2 and IBP Module
Intensive Care Multipara ECG Heart Rate Patient Monitor with Etco2 and IBP Module

 
Company Profile

Kindle Medical Devices Co. Ltd is a manufacturer of In Vitro Diagnosis equipment with more than 10 years of experience and a supplier of other medical equipment. We provide a one-stop solution for hospital projects, clinic projects, University, laboratory, and government tender. We supplied medical equipment and trained local distributors and engineers in more than 100 countries in Africa, Asia, Eastern Europe, Central America, and South America, and obtained good reputations because of our competitive price, high-quality products, and excellent service.
Here we sincerely hope we can build up mutual business cooperation in the near future.

Our Goal: Producing or introducing more cost-effective medical equipment, to support human health care.
FAQ
1. who are we?
We are based in Guangdong, China, start from 2011,sell to Africa(30.00%),Mid East(27.00%),Southeast Asia(10.00%),South Asia(5.00%),Central America(5.00%),Eastern Asia(5.00%),Oceania(3.00%),Southern Europe(3.00%),North America(3.00%),South America(3.00%),Western Europe(2.00%),Northern Europe(2.00%),Eastern Europe(2.00%). There are total about 11-50 people in our office.

2. how can we guarantee the quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3.what can you buy from us?
electrolyte analyzer, urine analyzer, hematology analyzer, coagulation analyzer, chemistry analyzer

4. what services can we provide?
Accepted Delivery Terms: FOB,CIF;
Accepted Payment Currency: USD;
Accepted Payment Type: T/T,PayPal,Western Union,Cash;
Language Spoken:English,Chinese