GD-2134E Cable Fault Identifier with Tracing and Depth Locating Function

China GD-2134E Cable Fault Identifier with Tracing and Depth Locating Function, Find details about China Cable Identifier, Cable Identification from GD-2134E Cable Fault Identifier with Tracing and Depth Locating Function

Model NO.
GD-2134E
Customized
Non-Customized
Color
Blue
Output Frequency
500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz
Output Power
Max.10W
Output Voltage
Max.200V (AC Peak Value)
Display
128*64 LCD Display
Built-in Lithium Battery
Nominal 14.8V, 7ah
External Power Supply
Rated Voltage DC12V (Car Cigarette Lighter Output
Charger
AC 100-240V Input, 50/60Hz, Output DC 16.8V, 2A/3A
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
China
HS Code
9030332000
Model NO.
GD-2134E
Customized
Non-Customized
Color
Blue
Output Frequency
500Hz, 1kHz, 8kHz, 33kHz, 66kHz, and 93kHz
Output Power
Max.10W
Output Voltage
Max.200V (AC Peak Value)
Display
128*64 LCD Display
Built-in Lithium Battery
Nominal 14.8V, 7ah
External Power Supply
Rated Voltage DC12V (Car Cigarette Lighter Output
Charger
AC 100-240V Input, 50/60Hz, Output DC 16.8V, 2A/3A
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
ISO, SGS
Origin
China
HS Code
9030332000
GD-2134E Cable Fault Identifier with Tracing and Depth Locating Function


GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults


Features
 
  1. Compass display: intuitively displays the pipeline location and left & right directions.
  2. Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies).
  3. Depth and current measurements, can display the signal strength historical curve.
  4. Fully digital high-precision sampling processing: stable and reliable, ultra-high sensitivity, narrow receiving passband, strong anti-interference ability, can fully suppress the power frequency and harmonic interference of adjacent running cables and pipelines.
  5. Running cable detection: high-performance transmission clamps, maximum coupling output signal to the running cable.
  6. Cable/pipeline identification: Flexible clamps (optional) are easy to use and clearly give identification results; stethoscopes (optional) can be used when it is not convenient to use clamps.
  7. Ground fault finding: HV booster (optional) boosts the maximum output voltage to 1000V, uses the A frame (optional) to locate the ground insulation breakage points of the pipeline, no need to adjust zero. The arrow indicates the direction of the fault point.
  8. Multiple detection frequencies: active detection and passive detection.
  9. A variety of signal output of the transmitter: direct connection output, clamp coupling output, radiation induction.
  10. High power output of transmitter, multiple output adjustable, automatic impedance matching and protection.
  11. Built-in large capacity lithium ion battery group, it will automatic shutdown undervoltage or long time no operation,
  12. Rugged case, light and portable.

Specifications

 
Transmitter
 
  1. Output modes: direct connection output, radiation induction, clamp coupling output(optional), fault locating HV booster(optional).
  2. Output frequency: 640Hz (compound frequency), 1280Hz (compound frequency), 10kHz, 33kHz, 82kHz, 197kHz.
  3. Output power: Max.10W, 10 gears adjustable, automatic impedance matching.
  4. Direct connection output voltage: maximum 150Vpp.
  5. Overload and short circuit protection.
  6. Man-machine interface: 320 x240 dot matrix LCD display.
  7. Built-in battery: 4 section 18650 lithium ion battery, nominal 7.4V, 6.8Ah.
 
Receiver

 
  1. Input mode: Built-in receiving coil, flexible clamp-on CTs(optional), Stethoscope(optional), A type fault detection device(optional).
  2. Receiving frequency:
    Active detection frequency for Pipes: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
    Power frequency passive detection frequency:50Hz/60Hz and 250Hz/300Hz(user configurable).
    RF passive detection frequency: the center frequency is 10kHz, 33kHz,82kHz respectively.
  3. Pipe detection mode: Wide peak method, narrow peak method, sound Valley method.
  4. Cable identification mode: flexible clamp-on CTs(optional) automatic identification and current measurement, stethoscope(optional) identification.
  5. 320*240 LCD display, shows signal amplitude, left/right direction, correct/false indication, history curve of signal strength, depth, current and result.
  6. Built-in battery, 2 section 18650 lithium ion battery, rated 7.4V, 3.4Ah
 
Others
 
  1. Dimension: Transmitter 280*220*90mm. Receiver 680*277*120mm.
  2. Weight: Transmitter 2.3kg. Receiver 2.0kg.
  3. Charger: AC100-240V input, 50/60Hz, output DC 8.4V,2A/3A.
  4. Working condition: Temperature -10-40ºC, Humidity 5-90% RH, altitude<4500m
Optional accessories (Specify when ordering, unspecified default unselected)
 
No.NameDrawings and instructions
1Connecting cable for receiver accessories.
Blue 6-core plug
2Connecting cable for transmitter accessories.
Red 5-core plug
3Clamp-on CT for transmitter 
4Flexible CT for receiver 
5A frame 
6Fault detection HV booster 
7Miniature stethoscope 
8Long stem stethoscope 
9Detection rod for long stem stethoscope 
GD-2134E Cable Fault Identifier with Tracing and Depth Locating Function
GD-2134E Cable Fault Identifier with Tracing and Depth Locating Function
GD-2134E Cable Fault Identifier with Tracing and Depth Locating Function
GD-2134E Cable Fault Identifier with Tracing and Depth Locating Function
GD-2134E Cable Fault Identifier with Tracing and Depth Locating FunctionGD-2134E Cable Fault Identifier with Tracing and Depth Locating FunctionGD-2134E Cable Fault Identifier with Tracing and Depth Locating FunctionGD-2134E Cable Fault Identifier with Tracing and Depth Locating FunctionGD-2134E Cable Fault Identifier with Tracing and Depth Locating Function