Thermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater Unit

China Thermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater Unit, Find details about China Low-Temperature Pump Price, Low Temperature Circulation Pump from Thermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater Unit

Model NO.
DLSB 5L-30
Compressor Number
1
Noise Level
Low
Certification
ISO, CE
Condition
New
Name
Evaporation Chiller
Tank Volume (L)
5L
Lowest No-Load Temperature(ºC)
-15
Using Temperature Range(ºC)
5~25
Environmental Relative Humidity (%)
≤70
Trademark
lanphan
Transport Package
400X260X530
Origin
Zhengzhou
Model NO.
DLSB 5L-30
Compressor Number
1
Noise Level
Low
Certification
ISO, CE
Condition
New
Name
Evaporation Chiller
Tank Volume (L)
5L
Lowest No-Load Temperature(ºC)
-15
Using Temperature Range(ºC)
5~25
Environmental Relative Humidity (%)
≤70
Trademark
lanphan
Transport Package
400X260X530
Origin
Zhengzhou
Thermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater Unit

Temperature Control Low-Temperature Coolant Circulation Pump

The capacity of our refrigeration pump can be 5L-500L

Temperature ranges from room temperature to -120 degrees

Product Description

Thermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater Unit

 

DLSB-5 Low Temp. Cooling Liquid Circulating Pump

 

The application of DLSB low temperature pump adopts mechanical refrigeration low temperature circulating equipment and provide constant current and constant voltage circulating liquid to meet the requirement of the decreasing instrument (electric microscope, electricity probe,x-ray machine,laser reactor and accelerator) so as to guarantee the required working temperature The machine is an essential to make sure the normal working condition for the device adopting constant current and constant pressure to cool in the condition of lacking water place ,bad quality of water and higher temperature.It can provide low temperature liquid to have multiple function of chemical reaction and medicine storage collocated with rotary evaporator,vacuum drying oven,circulating water multiple pump,magnetic force stirrer.It is especially used for different kinds of chemical biology ,physical lab which needed low temperature.It is the essential lab instrument for pharmacy,food industry,metallurgical industry and college scientific research.

 

TypeDLSB 5L-30°C
Tank volume (L)24.38
lowest no-load temperature(°C)-30
Using temperature range (°C)room temperature--30
best temperature range(°C)≤25
Environmental relative humidity (%)≤70
Working power supply (V/HZ)single phase220/50
temperature display modeliquid crystal
temperature stability(°C)±2
Sensor indexPt100
Instrument adjusting range (°C)±150
set wayArbitrary adjustment of Settings in the range of use
safety protectiondelay,leakage,over current,over heat
 1845
 1476
Output refrigerating capacity(w)984
 615
 246
Total machine power (W)1350
Machine current (A)7.2
refrigerantR404A
circulating pump100
 20
 6
 14
opening size(mm)260L*260
tank shapesquare
internal diameter and height of liquid storage tank(mm)290*290*290
overall appearance size(mm)565*460*845
machine weight(kg)60
fuse15A

 

Thermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater UnitThermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater Unit
Turn on and off:

The right turn to turn on the machine: Add the appropriate refrigerating medium-connect the power with the special power supply-turn off the circulation switch-press the power button-open the circulation switch-open the refrigerator switch-open the cooling equipment
The right turn to turn off the machine.Turn off the cooling equipment-turn off the refrigerator switch-turn off the circulation switch(stirring switch)-turn off the outlet valve(or discharge the cooling medium)-turn off the power supply -disconnect circuit breaker-disconnect the power line from the power supply-clean the equipment.

Corollary Equipment

Thermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater Unit

Related Products

 

The capacity of evaporation chiller can be 5L-500L
Temperature ranges  from room temperature to -120 degrees

Workshop

Thermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater UnitThermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater Unit

Contact Us

 

Q: Can the mixing motor be replaced with a low-power geared motor?

A: Yes.

 

Q: What materials can be used in the reactor?

A: The material can be made of carbon steel, 304, 316, etc.

 

Q: What anti-corrosion treatment can be done inside the reactor?

A: Spray anti-rust paint or spray PTFE layer or lining enamel.

 

Q: What are the payment methods?

A: Usually we accept wire transfer, Paypal, Western Union, Alibaba International Edition Alipay and so on. The specific payment method can be discussed in the transaction process.

 

Q: How to transport industrial chiller price ?

A: It depends on the quantity and value of the goods. Usually we use international express, air and sea.

 

Q: How do I package my product?

A: Packed in a fumigation-free wooden box.

Thermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater UnitThermostatic Refrigerated Continuos Circulation Circulating Pump Water Chiller Heater Unit