China 50W 12V Industrial Overload Protection Triple Output Power Supply with CE, Find details about China Switching Power Supply, Triple Output Power Supply from 50W 12V Industrial Overload Protection Triple Output Power Supply with CE
50W Triple Output 5V 12V -12V Power Supply T-50B
Features:SPECIFICATIONS | ||||||||||||
OUTPUT | ||||||||||||
Model | T-50A | T-50B | T-50C | T-50D | ||||||||
Output number | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC Voltage | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 12V | 24V |
Rated Current | 7A | 1A | 1A | 5A | 1A | 1A | 4A | 1A | 1A | 3A | 1A | 1A |
Current Range | 0.6-7A | 0.2-1A | 0.2-1A | 0.6-5A | 0.2-1A | 0.2-1A | 0.6-4A | 0.2-1A | 0.2-1A | 0.6-4A | 0.2-1.2A | 0.2-1.2A |
Rated Power | 52W | 49W | 50W | 51W | ||||||||
Ripple & Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 50mVp-p | 120mVp-p | 100mVp-p |
Voltage Adj. Range | CH1: -5%, +10% | CH1: -5%, +10% | CH1: -5%, +10% | CH1: -5%, +10% | ||||||||
Voltage Tolerance | ±2% | ±5% | ±5% | ±2% | ±5% | ±5% | ±2% | ±5% | ±5% | ±2% | ±6% | ±6% |
Setup, Rise, Hold Up Time | 200ms,100ms,16ms at full load | |||||||||||
INPUT | ||||||||||||
Voltage Range | 85~132VAC/170~264VAC selected by switch 47-63Hz; 240~370VDC | |||||||||||
AC Current | 1.6A/115V 0.8A/230V | |||||||||||
Efficiency | 66% | 69% | 71% | 72% | ||||||||
Inrush Current | Cold start 20A/115V 40A/230V | |||||||||||
Leakage Current | <0.5mA/240VAC | |||||||||||
PROTECTION | ||||||||||||
Over Load | 105%~150% | |||||||||||
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed. | ||||||||||||
ENVIRONMENT | ||||||||||||
Working Temp., Humidity | -10ºC~+60ºC; 20%~90%RH | |||||||||||
Storage Temp., Humidity | -20ºC~+85ºC; 10%~95%RH | |||||||||||
Vibration | 10~500Hz, 2G 10min./1 cycle, period for 60min, each along X, Y, Z axes | |||||||||||
SAFETY | ||||||||||||
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||||||||
STANDARD | ||||||||||||
Safety Standard | Design refer to UL1012 | |||||||||||
OTHERS | ||||||||||||
Dimension | 159*97*38mm(L*W*H) | |||||||||||
Weight | 0.54Kg | |||||||||||
Packing | 24pcs/14Kg/0.75CUFT |
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation
Shirley Contact information
Any questions
please be free to contact Shirley at :