China 1000W-7000W Solar Power UPS Inverter Accept AC and Generator Output, Find details about China off Grid Inverter, Solar Power System from 1000W-7000W Solar Power UPS Inverter Accept AC and Generator Output
LED Model | LWS1000 | LWS1500 | LWS2000 | LWS3000 | LWS4000 | LWS5000 | LWS6000 | LWS7000 | LWS8000 | |
LCD Model | LWS1000-C | LWS1500-C | LWS2000-C | LWS3000-C | LWS4000-C | LWS5000-C | LWS6000-C | LWS7000-C | LWS8000-C | |
Nominal Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 7000W | 8000W | |
AC Input | Phase & waveform | Single Phase & Pure Sine Wave | ||||||||
Norminal Voltage | 120VAC/230VAC OR 220/230/240VAC | |||||||||
Acceptable Voltage | 95-126VAC OR 194-253VAC±4% | |||||||||
Line Low Disconnect | 85V±4% OR 184±4% (154 wide mode±4%) | |||||||||
Line Low Reconnect | 95V±4% OR 194 ±4%(164 wide mode±4%) | |||||||||
Line High Disconnect | 136V±4%/274±4% | |||||||||
Line High Reconnect | 126V±4%/264±4% | |||||||||
Frequency | 50Hz(41-54) or 60Hz(51-64) (auto sensing) | |||||||||
Output | Phase & Waveform | Single Phase & Pure Sine Wave (bypass mode sync to input) | ||||||||
Voltage | 110/120/130VAC OR 220/230/240VAC±10%rms (bypass mode sync to input) | |||||||||
Voltage Regulation | ±10%rms (bypass mode sync to input) | |||||||||
Frequency | 50Hz±0.3Hz OR 60Hz±0.3Hz (bypass mode sync to input) | |||||||||
Peak Power | 3 times of rating power | |||||||||
Short Circuit Protection | Yes, shutdown after 10ms | |||||||||
Power Factor | 0.9-1.0 | |||||||||
DC Input | Battery Voltage | 12/24Vdc | 12/24/48Vdc | 24/48Vdc | 48/72Vdc | |||||
Minimum Start Voltage | 10V for 12V, 20V for 24V, 40V for 48V | |||||||||
Low Battery Alarm | 10.5±0.3Vdc for 12V, 21±0.6Vdc for 24V, 42V±1.2for 48V | |||||||||
Low Battery Transfer | 10V±0.3Vdc for 12Vdc, 20V ±0.6Vdcfor 24V, 40V ±1.2Vdcfor 48V | |||||||||
High Voltage Alarm | 16V±0.3 for 12V, 32V ±0.6for 24V, 64±1.2V for 48V | |||||||||
High DC Input Recovery | 15.5±0.3Vdc or 31±0.6Vdc or 62V±1.2Vdc | |||||||||
Max Charge Current | 20A/35A/50A/75A/90A(According to the inverter model) | |||||||||
Transfer Efficiency | Line Mode | >96% | ||||||||
Battery Mode | >85% | |||||||||
System Parameter | Power Saver | Load<=25W(Enabled on "P/S auto"setting of Remote Control | ||||||||
Audible Alarm | Souding when the heat sink 's temperature is over 100ºCand shut down after 30 seconds | |||||||||
Over Load Protection | 110%<Load<150%,beep 0.5s every 1s,and fault after 60s | |||||||||
Load>150%,beeps 0.5s every 1s,and fault after 20s | ||||||||||
Protections | low battery,over charging,over temp,over load | |||||||||
Communications | RS-232/USB/SNMP(custom-made) | |||||||||
Operating Environment | 0-40ºC,0-90%RH(non-condensing) | |||||||||
Audible Noise | <60dB | |||||||||
Net Weight(KG) | 15.5 | 18 | 20 | 25.5 | 36 | 39.5 | 48 | 55 | 60 | |
Dimension, L X W X H(mm) | 470×223×185mm | 650×223×185mm |