China 2X1.5mm Silicone Insulation Fire Warning Fire Resistant pH30 & pH120 Cable, Find details about China Fire Resistant Cable, Fire Warning Cable from 2X1.5mm Silicone Insulation Fire Warning Fire Resistant pH30 & pH120 Cable
Fire Resistant cable with Halogen free compounds is mainly used for installation of fire alarm and emergency evacuation systems, where long term electrical circuits are required under fire conditions, and to prevent loss of life and property eg. in industrial complexes, power stations, communal establishments, hotels, airports, underground railway networks, hospitals and outpatient clinics, department stores, data processing centres, theatres, cinemas, in multi-storey buildings, public gatherings, schools, etc. mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems.
Suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonry walls and in concrete.
These cables are suitable for outdoor and underground applications when installed in conduits or tubes. When installed in conduit, all precautions must be taken that no accumulation of water can occur in the pipes.
Supplied in 500 metre rolls.
SPECIFICATIONS
1. Flame retardant, fire rated security and fire warning cable
2. Conforms to BS EN 50200 and tested to BS6387
3. Voltage rating U / U 300 / 500 V
4. Cable Construction Twisted 2C x 1.0 Sq.mm + E
5. Conductor Resistance 18.1 Ω / km
6. Outer Diameter PH30 - 7.8 mm PH120 - 9 mm
7. Operating temperature -15 °C to 70 °C
FEATURES
1. Versatile use for RS485 communication, Addressable system and Conventional system wiring
2. Tested to IEC 60332-1, Cat CWZ TO BS:6387, BS EN 50200
3. No short circuit under a direct flame of up to 850 °C for the duration equivalent to the rating
4. PH30 Functionality assures the functional performance of emergency systems up to 30 minutes
5. PH120 Functionality assures the functional performance of emergency systems up to 120 minutes
6. Class 2 stranded copper conductor
7. Core wrapping with special mica impregnated glass fibre tape Red outer jacket
8. Screening with alu-laminated polyester tape and stranded tinned copper drain wire
ELECTRICAL DATA (AT20OC) | ||||||
Minimum Bend Radius | Min. Insulation resistance | Max.Working Temperature | Test voltage (rms value) | Max. Operating voltage peak value | ||
MΩ/km | ºC | V | V | |||
8×Diameter | 300 | -40ºC~+90ºC | 1000 | 300/500 | ||
TYPES AND MECHANICAL DATA | ||||||
Types (mm2) | Conductor | Insulation | Shielded1/ Drain Wire / Shielded2 | Level of twisting | Jacket Matterial | OD of Jacket (mm) |
2×1.0 | BC Class 1,5 | Rubber | Fiber Tape/AL-Foil | TC | FR-LSZH | 7.00±0.20 |
4×1.0 | BC Class 1,5 | Rubber | Fiber Tape/AL-Foil | TC | FR-LSZH | 8.00±0.20 |
2×1.5 | BC Class 1,5 | Rubber | Fiber Tape/AL-Foil | TC | FR-LSZH | 7.50±0.20 |
4×1.5 | BC Class 1,5 | Rubber | Fiber Tape/AL-Foil | TC | FR-LSZH | 8.60±0.20 |
2×2.5 | BC Class 1,5 | Rubber | Fiber Tape/AL-Foil | TC | FR-LSZH | 8.50±0.20 |
4×2.5 | BC Class 1,5 | Rubber | Fiber Tape/AL-Foil | TC | FR-LSZH | 10.0±0.20 |
2×4.0 | BC Class 5 | Rubber | Fiber Tape/AL-Foil | TC | FR-LSZH | 9.80±0.20 |
4×4.0 | BC Class 5 | Rubber | Fiber Tape/AL-Foil | TC | FR-LSZH | 11.70±0.20 |
*Notes | Class Types: | Class1: Solid / Class 5: Flexible | ||||
FR-LSZH: | LSZH thermoplastic material Type LTS3 to BS 7656-6.1 | |||||
Silicone Rubber: | High performance silicone rubber EI2 to BS EN 50363-1 | |||||
TECHNICAL DATA | ||||||
Types (mm2) | Max.Resistance of Cond.at 20ºC | Current Carrying Capacity(Amperes) | Nominal Capacitance (pF/m) | |||
Class 1,2 | Class 5 | Clipped | In Conduit | Core | Screen | |
1.00 | 18.10 Ω/km | 19.50 Ω/km | 19 | 17 | 100 | 170 |
1.50 | 12.10 Ω/km | 13.30 Ω/km | 24 | 22 | 110 | 190 |
2.50 | 7.41 Ω/km | 7.98 Ω/km | 33 | 30 | 130 | 220 |
4.00 | 4.61 Ω/km | 4.95 Ω/km | 45 | 40 | 160 | 270 |
Order Informations: | ||||||
Marking | HONGDA CABLE PH120 SR 114E Enhanced Cable N*NNmm2 XXX M | |||||
Package | 500M/Wooden Spool, 1 Spool/Carton |