600V 12 AWG Thwn Wire

China 600V 12 AWG Thwn Wire, Find details about China Tw Wire, Thw Wire from 600V 12 AWG Thwn Wire

Model NO.
THWN Wire
Material Shape
Round Wire
Range of Application
LSOH
Certification
ISO9001, CE, UL, CCC, TUV
Brand
Rneda
Certificate
UL CE SABS ISO CCC
Size
12 AWG
Voltage
600V
Cross Section
14 AWG-750mcm
Insulation Color
Blue,Red, Green,Yellow,Blank and So on
Trademark
RNEDA
Transport Package
Flexible Package
Specification
IEC DIN ASTM VDE BS
Origin
China
HS Code
8544492100
Model NO.
THWN Wire
Material Shape
Round Wire
Range of Application
LSOH
Certification
ISO9001, CE, UL, CCC, TUV
Brand
Rneda
Certificate
UL CE SABS ISO CCC
Size
12 AWG
Voltage
600V
Cross Section
14 AWG-750mcm
Insulation Color
Blue,Red, Green,Yellow,Blank and So on
Trademark
RNEDA
Transport Package
Flexible Package
Specification
IEC DIN ASTM VDE BS
Origin
China
HS Code
8544492100
600V 12 AWG THWN Wire 

600V 12 AWG Thwn Wire


Standard
The product is manufacture according to the standard of Q/320282DCE010-1999or JB/T10261-2001,and the same time is also manufactured according to the standard of IEC,English,Germany and America.

Applications
PVC insulated and Nylon jacketed wires and cables is suitable for power device with fixation installation and ratel voltage up to and including 450/750V.

Operating characteristics
Rated power - frequency voltage Uo/U:450/750V and 300/500V.
Max.admissible operating temperature of conductor:
BVN,BVNVB:70°C
BVN-90:90°C
The installation temperature should be not below 0°C
The bending radius of cable:
D≤25mm.:≥4D
D>25mm.:≥6D
(D-Diameter of the cable)

General purpose building wire for services, feeders and branch circuits.
Temperature rating not to exceed:
THHN/THWN: 90°C dry and dump, 600V
THHN/THWN: 75 °C wet or in oil, 600V
THWN-2: 90°C Dry, wet or in oil,600V  

1. Application:
General purpose building wire for services, feeders and branch circuits.
Temperature rating not to exceed:
THHN/THWN: 90°C dry and dump, 600V
THHN/THWN: 75 °C wet or in oil, 600V
THWN-2: 90°C Dry, wet or in oil,600V  

2. Construction:
Conductor: Annealed Copper, solid or stranded sizes 14AWG up to 1000MCM
Insulation: Premium Grade Flame Retardant Polyvinyl Chloride( PVC)
Jacket: Tough Polyamide (Nylon)

3. Standard&Test Specification:
THHN/THWN-2 Conforms to following standards:
UL83 for Thermoplastic Insulated Wire and Cables(THHN/THWN-2)
UL758 for Appliance Wiring Materials(AWM)
UL1063 for Machine Tool Wire(MTW)(Stranded Conductor Only).
SizeSectionCu Cond.Cond
Dia.
PVC
Thick
Nylon
Thick
OD
AWG
/MCM
Mm2Wire no./mmmmmmmmmm
142.081/1.631.630.380.12.59
123.311/2.052.050.380.13.01
105.261/2.592.590.510.13.81
142.0819/0.381.90.380.12.86
123.3119/0.472.350.380.13.31
105.2619/0.63.000.510.14.22
88.3719/0.753.750.760.135.53
613.319/0.954.750.760.136.53
421.219/1.195.951.020.158.29
326.719/1.336.651.020.158.99
233.619/1.57.51.020.159.84
142.419/1.688.41.270.1811.3
1/053.519/1.899.451.270.1812.35
2/067.419/2.1210.61.270.1813.5
3/08519/2.3811.91.270.1814.8
4/010719/2.6713.351.270.1816.25
25012737/2.0914.631.520.218.07
30015237/2.2916.031.520.219.47
35017737/2.4717.291.520.220.73
40020337/2.6418.481.520.221.92
50025337/2.9520.651.520.224.09
60030461/2.5222.681.780.2326.70
75038061/2.8225.381.780.2329.40
100050761/3.2529.251.780.2333.27
 
600V,90°C/75°C Dry or Wet PVC Insulated and Polyamide(Nylon)Jacketed.