350A or 210A 48VDC Output Telecom Rectifier Embedded Power Systems

China 350A or 210A 48VDC Output Telecom Rectifier Embedded Power Systems, Find details about China Power Supply, 48VDC Telecom Rectifier from 350A or 210A 48VDC Output Telecom Rectifier Embedded Power Systems

Model NO.
SPS350-48/SR4850
Certification
CE, RoHS, ISO
Brand
Jetpower
Rack Size
19′′
Color
Black
Trademark
JETPOWER
Transport Package
Standards Export Packing
Specification
W482*D330*H266mm/18kg
Origin
China
HS Code
85044020
Model NO.
SPS350-48/SR4850
Certification
CE, RoHS, ISO
Brand
Jetpower
Rack Size
19′′
Color
Black
Trademark
JETPOWER
Transport Package
Standards Export Packing
Specification
W482*D330*H266mm/18kg
Origin
China
HS Code
85044020

350A or 210A 48VDC Output Telecom Rectifier Embedded Power Systems
 

SPS series systems are compact and intelligent power system with capacity from 30A to 250A, containing rectifier modules, controller module, AC connection and DC connection. In addtion, easy installation to compact size add to the success of the system 

Product features:

1.  19" 1U, 3U, 4U, 5U, 6U sub-rack, easy to be embedded into all standard kinds of telecom equipment;

2.  System capacity from 30A to 350A;

3.  PFC technique features the system high efficiency, energy-saving and up to 0.99 power factor;

4.  Intelligent fan-cooling technique brings good cooling performance, low failure rate and high reliablity;

5.  Fast on-line expansion of rectifier modules enabled by hot-swap;

6.  N+1 rectifier module redundancy.

 

ModelSPS350-48/SR4830 
Rated Output Current350A
Rated Output Voltage53.5Vdc (42-58 Vdc)
Output Power20KW
AC  Input
AC Input Voltage Range380vac 3 phase; 220vac 1 ph tolerances: 85~300vac 
AC Input Frequency45Hz ~65Hz
AC input Power Factor≥0.99
AC transfer Efficiency≥92%
AC Input Lightening Protection    ClassC SPD
DC Output 
Output Voltage Range42~58 Vdc
Current Share±5%
Load Regulation≤0.5%
Voltage Regulation≤0.1%
Environment
Operating Temperature(-20 to 50°C) (Rectifier Temp Range: -45°C to 75°C)
Relative Humidity5%~95% RH, No Condensation
Configuration
Slots for Rectifier Module7 pcs
Rectifier Module5*sR4850
Controller1*CAS-03D
DC Distribution customizable
Battery Breaker2*125A/1P
Alarm Relay4pcs
Others
StandardUL60950/EN60950, EN55022, RoHS
Communication PortSNMP, RS232/RS485, Dry contact
Subrack Dimension(W*D*H) 482*330*266(6U)
Optional2nd LVD, DC Lightning Protection
OthersThe LVD shall be connected between the battery/charger connection point and the load.
The LVD shall disconnect the load from the battery and the rectifier if the battery voltage 
reached the predetermined end of discharge limit.
The LVD shall automatically reconnect the load when the battery voltage recovers to an 
acceptable level.
The LVD shall operate as follows:
§ Low voltage disconnect: -43.2 VDC (default)
§ Reconnect voltage: -48.0 VDC (default)
§ Voltage drops shall be considered in setting the above parameters.
The LVD contactor used shall have an indication that permits visual verification of the 
contact position whether open or closed.

350A or 210A 48VDC Output Telecom Rectifier Embedded Power Systems350A or 210A 48VDC Output Telecom Rectifier Embedded Power Systems