China AC/DC Single Output Switching Power Supply 350W 48VDC, Find details about China 350W48VDC, Power Supply from AC/DC Single Output Switching Power Supply 350W 48VDC
Model | S-350-5 | S-350-7.5 | S-350-12 | S-350-13.5 | S-350-15 | S-350-24 | S-350-27 | S-350-48 | |
Output | DC Voltage | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
Rated Current | 50A | 40A | 29A | 25.8A | 23.2A | 14.6A | 13A | 7.3A | |
Current Range | 0 ~ 50A | 0 ~ 40A | 0 ~ 12A | 0 ~ 13.5A | 0 ~ 23.2A | 0 ~ 14.6A | 0 ~ 13A | 0 ~ 7.3A | |
Rated Power | 250W | 300W | 348W | 348.3W | 348W | 350.4W | 351W | 350.4W | |
Ripple & Noise (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | |
Voltage Adj. Range | 4.5 ~ 5.6V | 6~9V | 10~13.2V | 12 ~ 15V | 13.5~18V | 20~26.4V | 26 ~ 32V | 41 ~ 56V | |
Voltage Tolerance Note.3 | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Setup,Rise, Hold time | 200ms, 50ms, 20ms at full load | ||||||||
Input | Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC by switch 254 ~ 370VDC | |||||||
Frequency Range | 47~63HZ | ||||||||
Efficiency(Typ.) | 73% | 76% | 83% | 83% | 84% | 85% | 86% | 87% | |
AC Current | 6.5A/115VAC 4A/230VAC | ||||||||
Inrush Current (max.) | 50A/115VAC 50A/230VAC | ||||||||
Leakage Current | <3.5mA / 240VAC | ||||||||
Protection | Over Load | 105 ~ 135% rated output power | |||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||
Over Voltage | 5.75 ~ 6.75V | 9.4 ~ 10.9V | 13.8V~16.2V | 15.5 ~ 18.2V | 18V~21V | 27.6V~32.4V | 33.7 ~ 39.2V | 57.6 ~ 67.2V | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||
Function | Fan on/ off Control | RTH3 ≥55°c FAN ON, ≤45°c FAN OFF, ≥80°c output shutdown (5 ~ 7.5V) | |||||||
RTH3 ≥65°c FAN ON, ≤55°c FAN OFF, ≥80°c output shutdown (12 ~ 15V) | |||||||||
RTH3 ≥70°c FAN ON, ≤60°c FAN OFF, ≥85°c output shutdown (24 ~ 48V) | |||||||||
Environment | Working Temperature | -10 ~ +50°c (Refer to output load derating curve) | |||||||
Working Humidity | 20~90% RH Non-condensing | ||||||||
Storage temp.& humidity | -20~+85°C, 10~95%RH | ||||||||
Temp. coefficient | ±0.03%/°C (0~50°C) | ||||||||
Vibration | 10 ~ 500Hz, 2G 10min./1 cycle,60min.each along X,Y,Z axes | ||||||||
Safety & | Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||
EMC | Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||||||
Others | MTBF | 234.3K hrs min. MIL-HDBK-217F ( 25°c ) | |||||||
Dimension | 215*115*50mm (L*W*H) | ||||||||
Packing | 1.07Kg; 12pcs/13.5Kg/0.92CUFT | ||||||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°c of ambient temperature. | ||||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. |