China MPPT 50A 48V 96V 7000W Low Frequency DC AC Hybrid Solar Inverters Power Inverter, Find details about China Sine Power Inverter, Cheap Solar Inverter from MPPT 50A 48V 96V 7000W Low Frequency DC AC Hybrid Solar Inverters Power Inverter
Model | GSI-102 | GSI-152 | GSI-202 | GSI-302 | GSI-402 | GSI-502 | GSI-602 | GSI-702 | |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | 7KW | |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | 21KW | |
Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC | ||||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | |||||||
AC Mains input range | 140-275VAC (220/230/240VAC)±4% | ||||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) | ||||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | |||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | ||||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | ||||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | ||||||||
Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm | ||||||||
High temperature | Built-in temperature real time sensor, ≥85ºC alarm, ≥90ºC automatic shutdown | ||||||||
Short circuit protection | Automatic shutdown | ||||||||
Output | Transfer efficiency | ≥92% | |||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | ||||||||
Output frequency | (DC battery mode) 60/50Hz±1% | ||||||||
Output wave form | Pure sine wave | ||||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | ||||||||
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; | ||||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | |||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | |||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | ||||||||
Other | Transfer time | Bult- in AC bypass replay (≤4ms) | |||||||
Display | LCD Display with function buttons | ||||||||
Cooling system | Intelligent cooling fan control system | ||||||||
≤42ºC slow fan, ≥45ºC fast fan | |||||||||
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) / | |||||||
Deep sulphation cycle 15.5 for 4 hrs | |||||||||
AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | ||||||||
AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages charging current adjustable | ||||||||
3 Stages charging | Boost charging, direct charging, float charging | ||||||||
AC over charge protection | Battery voltage >=16VDC (12V) >=32VDC (24V) >=64VDC (48V), stop charging after 60s alarm | ||||||||
Working mode (Optional) | 01 | AC mains priority | |||||||
Always use AC mains as priority input to provide AC output and automatically charge the battery, only | |||||||||
stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off | |||||||||
02 | Energy saving | ||||||||
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on | |||||||||
03 | DC battery priority | ||||||||
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts | |||||||||
DC to AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC | |||||||||
output and automatically start charging the battery (for 24V/48V system, multiply by 2/4 accordingly) | |||||||||
Comnunication | RS-232/USB/SNMP(additional option) | ||||||||
Environment | Temperature | -20~+75ºC | |||||||
Humidity | <95% | ||||||||
MPPT Solar Controller specification | Charging & discharging | 30A / 50A | 50A | ||||||
Max. PV input voltage | Max. 30V(12V) / 50V (24V) / 100V (48V) | ||||||||
Max. PV array Power | 360W (12V) / 720W (24V) | 1200W (24V) / 2400W (48V) | |||||||
MPPT range | 12-60VDC 12V & 24V system | 24-120VDC 24V & 48V system | |||||||
Max. PV array open circuit | 70VDC | 150VDC | |||||||
System voltage | 12V & 24V / 24V & 48V automatic recognition | ||||||||
No load current | <5mA | ||||||||
Charging circuit drop | ≤0.2V | ||||||||
Discharging circuit drop | ≤0.15V | ||||||||
Over charge protection | 17V (12V) / 34V (24V) / 68V (48V) stop charging | ||||||||
Boost charging | 14.6V (12V) / 29.2V (24V) / 58.4V (48V) Duration: 30mins | ||||||||
Direct charging | 14.4V (12V) / 28.8V (24V) / 57.6V (48V) Duration: 30mins | ||||||||
Float charging | 13.6V(12V) / 27.2V (24V) / 54.4V (48V) until reach charging recovery voltage | ||||||||
Charging recovery | 13.8V (12V) / 27.6V (24V) / 55.2V (48V) | ||||||||
Over discharging recovery | 12.5V (12V) / 25V (24V) / 50V (48V) | ||||||||
Low voltage | 10.5V (12V) / 21V (24V) / 42V (48V) alarm | ||||||||
Over discharging | 10V (12V) / 20V (24V) / 40V (48V) automatic shutdown | ||||||||
Temperature compensation | -4.0mv/ºC/2V(Boost charging, Direct charging, float charging and charging recover voltage compensation) | ||||||||
Control method | MPPT smart charging, maximum power point tracking | ||||||||
Working temperature | -20~+75ºC | ||||||||
Circuit protection | Overcharging, over discharging, overload and short circuit protection | All protections are harmless to any parts and fuse of the controller; fuse is only for ultimate protection. | |||||||
Anti-connection-reverse protection for solar panel | |||||||||
Appearance | Product size (mm) | 460*245*200mm | 630*280*200mm | ||||||
Packing size (mm) | 530*335*255mm | 740*355*275mm | |||||||
Net Weight (kg) | 11.2kg | 13.2kg | 14.8kg | 16.8kg | 25kg | 28kg | 32.5kg | 36kg | |
Gross Weight (kg) | 13.5kg | 15.5kg | 17.1kg | 21.8kg | 28.4kg | 31.5kg | 35.9kg | 39kg | |
*Product specifications are subject to change without further notice |