Chemical Cosmetic 2.0nm Flame Faas Absorption Spectrometer

China Chemical Cosmetic 2.0nm Flame Faas Absorption Spectrometer, Find details about China Spectral, Light Source from Chemical Cosmetic 2.0nm Flame Faas Absorption Spectrometer

Model NO.
AA-1800H
Wavelengths
Infrared Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Non-Customized
Trademark
Macylab
Transport Package
Carton
Origin
Beijing
Model NO.
AA-1800H
Wavelengths
Infrared Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Non-Customized
Trademark
Macylab
Transport Package
Carton
Origin
Beijing
   

Chemical  Cosmetic Flame Atomic Absorption Spectrometry Hollow cathode lamps

 

Specifications:

Mainframe
Model:AA-1800H
Light Source:≤6 lamps automatic turret, automatic alignment
Power Supply:110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current:pulsed power supply
Optical System:large 1800 /mm grating ruling, full closed optical system
Wavelength Range:180nm-900nm                  
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy:≤0.15nm
Wavelength Repeatability:±0.1nm
Spectral Bandwidth:0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
(5 steps with automatic changeover)
Baseline Stability:≤±0.002A/30 min (Static)      
≤±0.005A/30min (Dynamic)
Absorbance Range:0-4A
Detector:imported photomultiplier tube 
Flame Analytical System
Burner Head:full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber:polymer explosion-proof spray chamber
Nebulizer:atomizer efficient glass atomizer, can also be customized
Ignition Type:microcomputer control, automatic ignition
Gas Control:automatic gas control system
Detection Limits(Cu):0.002μg/mL
Precision:RSD≤0.5%
Graphite Furnace Analytical System
Heating Mode:vertical heating
Temperature Control Method:vertical optical temperature monitoring graphite tube wall temperature
Temperature Range:room temperature to 3000ºC
The Program:automatic temperature control up to 20 order
Temperature Control:the furnace enriched up to 20 times
Characteristics Volume:0.5 × 10-12g (Cd)
Detection Limit:0.4 × 10-12g (Cd)
Precision:RSD≤3%
The Cooling Water:can choose cooling water circulation system
Safety:the graphite tube damage, water flow
air pressure and other alarmtemperature overheating protection
Autosampler Graphite Furnace
Sample Tray:70 sample cups, 6 reagent cup
Sample Volume:1-100μl
The Smallest Lincrement:0.1 μl
The Volume of Samplebetter than 1%(at the time of 10mL-100mL)
Repeatability Volume
Repeated Sampling Frequency:up to 99 Times
Cleaning and Wasteeach 500mL
Container Volume

 

 

Applications:

 

AA-1800H atomic absorption spectrophotometer is now widely used in scientific research,quality control,

disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and

software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples,

equipment maintenance, simple and convenient

 

Competitive Advantage:

High precision automatic optical system
1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 6 socket configuration six independent lamp power supply, can be respectively preheating 
Polymer spray chamber
Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability
Titanium burner
Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame
Automatic analysis
It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.
The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automaticwavelength scanning and searching peak
Software function
High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method
Graphite furnace temperature control
Gas dual temperature control inside and outside, 20 order linear or nonlinear heating, to ensure that the measured elements has the highest sensitivity; furnaceenriched up to 20 times, the longitudinal optically monitoring the graphite tube wall temperature, maximum temperature to 3000 degrees centigrade
High technology index
AA-1800 atomic absorption spectrophotometer elements testsensitivity meet international best level,sensitivity of less than or equal to0.015μg/mL/1%; baseline drift is less than 0.003Abs/30m, the stability is better than 0.005Abs/4h
Background correction system
Using deuterium hollow cathode lamp advanced and self absorption background deduction of background correction, to eliminate the interference of molecular absorption of low content determination, reducing the noise emission of deuterium lampand prolongs the service life, has excellent stability. Deuterium lamp background signalfor 1A, background correction ability > 50 times
Intelligent analysis
Greart intelligence, humanized design, flame and graphite furnace atomizer automatic switching, automatic optimization of graphite furnace atomizer, automatically set the flame height adjustment, automatic ignition, automatic optimization of the horizontal position, system automatically sets the gas flow. In the case of power failure, misoperation, acetylene leakage, the system will automatically start the safetyprotection function
Automatic sampler
Integrative design of graphite furnace, using high precision syringe, lowest in 0.5μl samples, with intelligent online dilution and concentration function