China 1550nm 1X2 2X2 Fiber Optical Pm Fused Coupler, Find details about China Pm Fbt Couplers, Pm Fused Coupler from 1550nm 1X2 2X2 Fiber Optical Pm Fused Coupler
Features
Applications
Specification
Item | Parameter | ||||||
Center Wavelength | 780, 840 | 980, 1064 | 1310, 1480, 1550 | ||||
Bandwidth | ±15, ±40 | ||||||
Max. Insertion Loss @ Central wavelength | CR | P | A | P | A | P | A |
50/50 | ≤3.8 | ≤4.0 | ≤3.6 | ≤3.8 | ≤3.4 | ≤3.6 | |
30/70 | ≤6.3/2.2 | ≤6.5/2.4 | ≤5.75/2.0 | ≤6.1/2.1 | ≤5.6/1.95 | ≤5.75/2.1 | |
20/80 | ≤8.2/1.7 | ≤8.5/1.9 | ≤8.0/1.5 | ≤8.2/1.7 | ≤7.6/1.4 | ≤8.0/1.5 | |
10/90 | ≤11.8/1.4 | ≤12.0/1.6 | ≤11.6/1.2 | ≤11.8/1.4 | ≤11/0.85 | ≤11.6/1.0 | |
5/95 | ≤15/1.0 | ≤15.2/1.2 | ≤14.8/0.8 | ≤15/1.0 | ≤14.2/0.6 | ≤14.8/0.8 | |
3/97 | ≤17.5/0.9 | ≤17.7/1.0 | ≤16.6/0.4 | ≤17.2/0.6 | ≤16.2/0.4 | ≤16.7/0.5 | |
2/98 | ≤19.0/0.8 | ≤19.2/1.0 | ≤18.4/0.4 | ≤18.9/0.5 | ≤18.0/0.4 | ≤18.5/0.5 | |
1/99 | ≤22.5/0.7 | ≤22.8/0.9 | ≤22/0.4 | ≤22.5/0.6 | ≤21.5/0.3 | ≤22/0.4 | |
ER | CR>5% | 20 | 18 | 20 | 18 | 20 | 18 |
5%≥CR>1% | 18 | 16 | 18 | 16 | 18 | 16 | |
CR≤1% | Out of concern | ||||||
Steel Tube Size | 3*54 | ||||||
Return loss | ≥50 | ||||||
Directivity | ≥50 | ||||||
Fiber type | Panda PM fiber | ||||||
Power handling | ≤500 | ||||||
Operating Environment Temperature | -5-+70 | ||||||
Storage Temperature | -40-+85 |
* IL is 0.3dB(1310~1550) or 0.5dB(980~1060) or 0.8dB(780~850) higher for devices with connectors.
** RL is 5 dB lower, ER is 2 dB lower for each connector added. Connector key is aligned to slow axis.