GDPT-103C CVT On-site Capacitance Voltage Transformer Calibrator

China GDPT-103C  CVT On-site Capacitance Voltage Transformer Calibrator, Find details about China Capacitance Voltage Transformer Calibrator, CT PT calibrator from GDPT-103C  CVT On-site Capacitance Voltage Transformer Calibrator

Model NO.
GDPT-103C
Measurement range
0.000mS-200.0mS
Delivery time
30 days
Product name
CVT On-site Calibrator Capacitance Voltage Transf
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
496*394*185mm
Origin
Wuhan China
HS Code
9030849000
Model NO.
GDPT-103C
Measurement range
0.000mS-200.0mS
Delivery time
30 days
Product name
CVT On-site Calibrator Capacitance Voltage Transf
Trademark
HV Hipot
Transport Package
Wooden Case
Specification
496*394*185mm
Origin
Wuhan China
HS Code
9030849000
GDPT-103C  CVT On-site Capacitance Voltage Transformer Calibrator
CVT On-site Calibrator  Capacitance Voltage Transformer Calibrator
GDPT-103C  CVT On-site Capacitance Voltage Transformer Calibrator
GDPT-103C  CVT On-site Capacitance Voltage Transformer Calibrator
GDPT-103C  CVT On-site Capacitance Voltage Transformer Calibrator

Overview

GDPT-103C CVT On-site Calibrator is designed for analyzing and Calibrate CVT for on-site test.


Features
  1. l 640*480 high resolution 10.4 inch LCD touch screen,
  2. l Single machine to realize error test of CVT, no need resonant voltage injection device, standard VT, load box, calibrator, greatly improve working efficiency and simplify the connection.
  3. l Broad test range, 35/√3kV/100/√3V, 100/3V-1000/√3kV/100/√3V, 100/3V.
  4. l Test 3pcs secondary winding of CVT at the same time.
  5. l Internal inductive voltage divider of class 0.02 and using difference measurement to test LV error of tested CVT. Inter-frequency testing technology is adopted, and calculating the non-linear error of intermediate transformer at 50Hz, to obtain the CVT error finally. The test accuracy is up to class 0.05.
  6. l Test capacitive divider ratio of CVT and check if the nameplate is the same with CVT or not.
  7. l During testing, max. test voltage is no more than 3kV, to ensure safety of on-site testing.
  8. l Easy wiring.
  9. l Test time is short, less than 5mins.
  10. l Using accurate software calculation, test data is more accurate.
  11. l Automatic judging the connection status. It will display wrong connection, wrong turns ratio and polarity.
  12. l Automatic rounding test data and determine if it is over error or not.
  13. l It will show the test result pass or fail directly.
  14. l Save up to 1000pcs test data.
  15. l With printer, to print test data directly.
  16. l With engineering plastic case, anti-shock.
Main parameters
 
Test range of turns ratio35/√3kV / 100/√3V, 100/3V, 100V
66/√3kV / 100/√3V, 100/3V, 100V
110/√3kV / 100/√3V, 100/3V, 100V
220/√3kV / 100/√3V, 100/3V, 100V
330/√3kV / 100/√3V, 100/3V, 100V
500/√3kV / 100/√3V, 100/3V, 100V
765/√3kV / 100/√3V, 100/3V, 100V
1000/√3kV / 100/√3V, 100/3V, 100V
Accuracyclass 0.05
Working range80%-120%
Secondary burden0.0VA-500VA, cosφ=0.1-1.0
Accuracy range of tested CVT1.0, 0.5, 0.2, 0.1
Admittance measurement error≤ 5.0%
Measurement range0.000mS-200.0mS
Test accuracy of capacitive divider ratioclass 0.1
Dimension496*394*185mm
WeightAbout 14kg
GDPT-103C  CVT On-site Capacitance Voltage Transformer Calibrator