China TBB All in One 2kw off on Grid Solar Inverter for Home Solar Power System 230V AC out, Find details about China Solar Inverter, Hybrid Solar Inverter from TBB All in One 2kw off on Grid Solar Inverter for Home Solar Power System 230V AC out
Model | Apollo Maxx 2.0M | Apollo Maxx 3.0M | Apollo Maxx 2.0S | Apollo Maxx 3.0S | Apollo Maxx 5.0S |
Product Topology | Transformer based | ||||
Power Assist | Yes | ||||
Parallel & three phase | Yes | ||||
AC input voltage range(VAC) | 175~265 | ||||
AC input Frequency range(Hz) | 45~65 | ||||
AC input Current (transfer switch) (A) | 32 | 50 | |||
Inverter | |||||
Nominal battery voltage (V) | 24 | 48 | |||
Input voltage range (V) | 21-34 | 42~68 | |||
AC output voltage(VAC) | 220/230/240 ± 2% | ||||
AC output Frequency(Hz) | 50/60 ± 0.1% | ||||
Harmonic distortion | <2% | ||||
Load Power factor | 1.0 | ||||
Cont. output power at 25°C (VA) | 2000 | 3000 | 2000 | 3000 | 5000 |
Max Output power at 25°C (W) | 2000 | 3000 | 2000 | 3000 | 5000 |
Peak power (5 sec)(W) | 6000 | 9000 | 6000 | 9000 | 15000 |
Surge | 300% | ||||
Maximum efficiency | 94% | 94% | 95% | 95% | 96% |
Zero load power (W) | 11 | 14 | 11 | 14 | 21 |
Charger | |||||
Charge voltage 'absorption' (V) | 28.8 | 57.6 | |||
Charge voltage 'float' (V) | 27.6 | 55.2 | |||
Battery types | AGM / GEL / OPZV / Lead-Carbon / Li-ion / Flooded/Traction/TBB SUPER-L | ||||
Max AC charge current (A) | 50 | 80 | 25 | 40 | 70 |
Temperature compensation | Yes | ||||
Solar Charge Controller | |||||
Max output current(A) | 60 | 60 | 60 | 60 | 90 |
Maximum PV power(W) | 2000 | 2000 | 4000 | 4000 | 6000 |
PV open circuit voltage (V) | 150 | 150 | 150 | 150 | 150 |
MPPT voltage range(V) | 65~145 | ||||
Charge voltage 'absorption' (V) | 28.8 | 57.6 | |||
Charge voltage 'float' (V) | 27.6 | 55.2 | |||
MPPT charger maximum efficiency | 98% | 98% | |||
MPPT efficiency | >99.5% | >99.5% | |||
Protection | a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) input voltage out of range | ||||
General data | |||||
Main Output (AC Out1) Current (A) | 32 | 50 | |||
Auxiliary Output (AC Out2) Current (A) | 32 | ||||
Transfer time | 0ms (<15ms in Weak AC source Mode) | ||||
Remote on-off | Yes | ||||
Programmable relay | 2x | ||||
Protection | a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) input voltage out of range g) input voltage ripple too high h) Fan block | ||||
CAN Bus communication port | For three phase operation, remote monitoring and system integration | ||||
General purpose com. Port | RS485 (GPRS,WLAN optional with kinergy) | ||||
Operating temperature range | -20˚C to 65˚C | ||||
Relative humidity in operation | 95% without condensation | ||||
Altitude (m) | 2000 | ||||
Mechanical Data | |||||
Dimension (mm) (max) | 499*272*145 | 499*272*145 | 499*272*145 | 499*272*145 | 560*310*155 |
Net Weight (kg) | 17 | 20 | 17 | 20 | 32 |
Cooling | Forced fan | ||||
Protection index | IP21 | ||||
Standards | |||||
Safety | EN-IEC 62477-1, EN-IEC 62109-1,EN-IEC 62109-2 | ||||
EMC | EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-3-11,EN61000-3-12 |