Infectious Disease Test Kits Dengue Duo Test Dengue Ns1 Test

China Infectious Disease Test Kits Dengue Duo Test Dengue Ns1 Test, Find details about China Dengue Igg/Igm Rapid Test Strip, Rapid Test Dengue from Infectious Disease Test Kits Dengue Duo Test Dengue Ns1 Test

Transport Package
Carton
Origin
Rugao, Nantong, Jiangsu, China
HS Code
3822001000
Transport Package
Carton
Origin
Rugao, Nantong, Jiangsu, China
HS Code
3822001000
 Infectious Disease Test Kits Dengue Duo Test Dengue Ns1 Test
Infectious Disease Test Kits Dengue Duo Test Dengue Ns1 TestInfectious Disease Test Kits Dengue Duo Test Dengue Ns1 TestInfectious Disease Test Kits Dengue Duo Test Dengue Ns1 TestInfectious Disease Test Kits Dengue Duo Test Dengue Ns1 Test
 
Details of products
Model Number:Dengue01Brand Name:Diagnos and OEM
Power Source:ManualAfter-sale Service:Online Technical Support
Specimen:Whole Blood /Serum/PlasmaFormat:Cassette
Accuracy:99.5%Shelf Time: 24-36Months
Certification:FSC/CE/ISO13485Warranty:2 years

Product Information

Test Procedure 
Step 1: Bring the specimen and test components to room temperature if refrigerated or frozen. Mix the specimen well prior to assay once thawed.
Step 2: When ready to test, open the pouch at the notch and remove device. Place the test device on a clean, flat surface.
Step 3: Be sure to label the device with specimen's ID number.
Step 4: For whole blood sample:
Fill the dropper with the specimen then add 1 dropper of specimen. The volume is around 10µL.
Note: Practice a few times prior to testing if you are not familiar with the mini dropper. For better precision, transfer specimen by a pipette capable to deliver 10µL of volume. 
For Plasma/ Serum sample: 
Fill the mini dropper with the specimen not to exceed the specimen line as showed in the following image. The volume of the specimen is around 5µL.
Note: Practice a few times prior to testing if you are not familiar with the mini dropper. For better precision, transfer specimen by a pipette capable to deliver 5µL of volume.

Holding the mini dropper vertically, dispense the entire specimen into the center of the sample well making sure that there are no air bubbles. Then add 2 drops (about 60-100 µL) of Sample Diluent immediately into the sample well.
Step 5: Set up a timer.
Step 6: Read the result at 15 minutes.
Don't read result after 30 minutes. To avoid confusion, discard the test device after
interpreting the result
 
Interpretation of Results
Production Process
 
FAQ

Q1.What's the method you use to do the test?

A: Colloidal Gold Method.

Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.  

Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.

Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.

Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.

Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts: 
1. Technical data: Such as the accuracy, specificity and sensitivity.
2. Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.
3. Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.
4. Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice.

 

Contact Us

Promise:We will offer our good after sale service always!as we strongly believe,QUALITY and SINCERE is very important among countries cooperations!

 

Welcome to enquiry .Pls feel free to contact us