China 6kv-500kv Variable Frequency AC Resonant Test Set /AC Hipot Test Equipment for Gis/Cable/Transformer /CT/PT, Find details about China Hipot Test Set, AC Withstand Tester from 6kv-500kv Variable Frequency AC Resonant Test Set /AC Hipot Test Equipment for Gis/Cable/Transformer /CT/PT
General Information:
SXBP Series AC Resonance Test System is specially designed for AC withstand test for electric equipments of substation at 10kV~500kV or below.
Applications:
√ Transformer
√ Cables
√ GIS System
√ Insulator
√ CT/PT
Features:
√ Small size, portable for operating.
√ Screen to show the test data, status and display operation step by real-time.
√ Small temperature rising at rated load. Dry-type epoxy cast, high mechanical strength and good insulation ability.
√ 220V or 380V single phase power source is suitable for on-site sourcing.
√ Different type reactors for optional realize the multipurpose.
√ With over current, over voltage, IPM and discharge protection function.
√ Test result can be printed.
Specifications:
√ Rated output voltage: 0~500kV or below
√ Output frequency: 20 -300Hz.
√ Resonant voltage waveform: sine wave, waveform Distortion rate ≤ 1%.
√ Full load working time: continuous working time 60mins.
√ Quality factor: max. load ≥ 20.
√ Frequency adjustment: fineness 0.1Hz, instability ≤ 0.01%.
√ Power supply: 220V or 380V single-phase.
Common Configuration:
Model | Test Object | Main Configurations: | |||
AC power source | Exciting Transformer | Reactor | Capacitive Voltage Divider: | ||
SXBP-27/54/108-108 Test Frequency: 20~300Hz | 31500kVA/35KV Power Transformer | 10KW 1 unit | 10KW 1 unit | 27KV/1A 4 Units Frequency: 20-300Hz | 120KV |
35KV circuit breaker, busbar, insulator | |||||
10KV(300mm2) cable 2000m | |||||
35KV(300mm2) cable 500m | |||||
SXBP-54/108/216-216 Test Frequency: 20~300Hz | 110KV Circuit breaker and busbar | 15KW 1 unit | 15KW 1 unit | 54KV/1A 4 Units Frequency: 20-300Hz |
|
110KV GIS ≤ 10 intervals | |||||
35KV (300mm2) cable 1500m | |||||
10KV (300mm2) cable 3000m | |||||
110KV Full Insulated Transformer | |||||
SXBP-65/130/260-520 Test Frequency: 20~300Hz | 110KV Circuit Breaker and busbar | 30KW 1 Unit | 30KW 1 Unit | 65KV/2A 4 Units Frequency: 20-300Hz | 300KV |
110KV GIS ≤ 10 intervals | |||||
110KV (300mm2) cable 800m | |||||
35KV (300mm2) cable 3000m | |||||
10KV(300mm2) cable 200m | |||||
110KV Full Insulated Transformer | |||||
SXBP-45/90/135/180/270-270 Test Frequency: 20~300Hz | 110KV Insulator, switchgear, GIS and etc. | 20KW 1 unit | 20KW 1 unit | 45KV/1A Six Units Frequency: 20-300Hz | 200KV |
50MW/110KV Full Insulated Transformer | |||||
110KV (300mm2) cable 200m | |||||
35KV Power Transformer, switchgear, CT/PT, cable, and etc. | |||||
20MW hydrogenerator | |||||
10KV power transformer, switchgear, CT/PT, cables and etc. | |||||
SXBP18/36/54 Test Frequency: 20~300Hz | 10KV (300mm2) cable 2000m | 5KW 1 Unit | 5KW 1 unit | 27KV/1A 2 units or 18KV/1A 3 units Frequency: 20-300Hz | 60KV |
35KV (300mm2) cable 500m | |||||
10KV power transformer, switchgear, CT/PT and etc. |
√ Model SXBP-27/54/108-108, SXBP is the model of series, 27/54/108 is: voltage of one reactor (KV)/voltage of two reactors in series connection/voltage of four reactors in series connection. 108 is the total capacity (KVA).
√ The test object is the common configuration for reference only. For details, please contact with us. If the capacity of your equipment is small and voltage is too low, can add more reactors to increase the capacity, and add more divider to increase the test voltage.
Please contact with us for further information, our technically expereinced expertise team will select correctly designed test set for you.