China 24VDC Air Accurate Analog Absolute Gauge Piezoresistive Customized Pressure Sensor MPM280, Find details about China Pressure Sensor, 19mm Diameter Pressure Sensor from 24VDC Air Accurate Analog Absolute Gauge Piezoresistive Customized Pressure Sensor MPM280
Item* | Min. | Typ. | Max. | Units |
Linearity | ±0.15 | ±0.25 | %FS,BFSL | |
Repeatability | ±0.05 | ±0.075 | %FS | |
Hysteresis | ±0.05 | ±0.075 | %FS | |
Zero output | ±1 | ±2 | mV DC | |
FS output** | 70 | mV DC | ||
Zero thermal error | ±0.75 | ±1.0 | %FS, @25ºC | |
FS thermal error | ±0.75 | ±1.0 | %FS, @25ºC | |
Compensated temp. range | 0~50 | ºC | ||
Working temp. range | -40~125 | ºC | ||
Storage temp. range | -40~125 | ºC | ||
Stability | ±0.2 | ±0.3 | %FS/year | |
*Testing at basic condition,G: Gauge; A: Absolute; S: Sealed gauge ** 0BG, FS output ≥45mV 0AG, FS output ≥60mV 02A, 03A, 02GY, 03GY, FS output ≥45mV 07A, 08A, 07GY, 08GY, FS output ≥60mV |
MPM280(TH/TS/Ti)* | Piezoresistive OEM Pressure Sensor | ||||||||||||||||
Range code | Pressure range | Ref. | Range code | Pressure range | Ref. | ||||||||||||
0B | 0kPa~20kPa | G | 12 | 0MPa~2MPa | G.A | ||||||||||||
0A | 0kPa~35kPa | G.A | 13 | 0MPa~3.5MPa | G.S.A | ||||||||||||
02 | 0kPa~70kPa | G.A | 14 | 0MPa~7MPa | S.A | ||||||||||||
03 | 0kPa~100kPa | G.A | 15 | 0MPa~10MPa | S.A | ||||||||||||
07 | 0kPa~200kPa | G.A | 17 | 0MPa~20MPa | S.A | ||||||||||||
08 | 0kPa~350kPa | G.A | 18 | 0MPa~35MPa | S.A | ||||||||||||
09 | 0kPa~700kPa | G.A | 19 | 0MPa~70MPa | S.A | ||||||||||||
10 | 0kPa~1000kPa | G.A | |||||||||||||||
Code | Pressure type | ||||||||||||||||
G | Gauge | ||||||||||||||||
A | Absolute | ||||||||||||||||
S | Sealed gauge | ||||||||||||||||
Code | Pressure connection | Installation | |||||||||||||||
0 or null | O-ring | ||||||||||||||||
H1 | M24×1 male (assembled, P≤2MPa) | C1~C11 are available for pressure connections for both assembled and welded type | |||||||||||||||
H2 | M27×2 male (assembled, P≤70MPa) | ||||||||||||||||
H3 | M24×1 male (welded, P≤2MPa) | ||||||||||||||||
H4 | M27×2 male (welded, P≤35MPa) | ||||||||||||||||
C1 | M20×1.5 male, face type seal | Pressure connection options for assembled or welded type | |||||||||||||||
C2 | G1/4 male | ||||||||||||||||
C3 | G1/2 male | ||||||||||||||||
C4 | G1/4 female | ||||||||||||||||
C5 | M20X1.5male waterline seal | ||||||||||||||||
C6 | 1/4NPT male | ||||||||||||||||
C7 | 1/4NPT female | ||||||||||||||||
C8 | 1/2NPT male | ||||||||||||||||
C9 | 1/2NPTfemale | ||||||||||||||||
C10 | R1/4 male | ||||||||||||||||
C11 | R1/2 male | ||||||||||||||||
PC1 | Flush diaphragm M20×1.5 male, | Top: M24×1 female | |||||||||||||||
PC2 | Flush diaphragm R1/2 male, | ||||||||||||||||
PC3 | Flush diaphragm G1/2 male, | ||||||||||||||||
PD1 | DN25 clamp | ||||||||||||||||
Code | Compensation | ||||||||||||||||
L | Laser trimming | ||||||||||||||||
M | Outer compensated resistor (providing resistor value) | ||||||||||||||||
Code | Electric connection | ||||||||||||||||
1 | Kovar pin(default) | ||||||||||||||||
2** | 100mm silicon rubber flexible wires | ||||||||||||||||
Code | Special measurement | ||||||||||||||||
Y | Gauge sensor to measure vacuum(0kPa~-100kPa) | ||||||||||||||||
MPM280 09 G 0 L 1 Y The whole spec |