Relay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke Detector

China Relay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke Detector, Find details about China Heat Sensor, Smoke Alarm from Relay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke Detector

Operating Voltage Range
12 to 28 VDC Volts
Spectrum
180~290nm
Protection Rating
IP 21
Relay Contact Load
1A@DC24V
Trademark
XHA
Transport Package
Carton
Specification
102mm*102mm*50mm
Origin
China
HS Code
8531100000
Operating Voltage Range
12 to 28 VDC Volts
Spectrum
180~290nm
Protection Rating
IP 21
Relay Contact Load
1A@DC24V
Trademark
XHA
Transport Package
Carton
Specification
102mm*102mm*50mm
Origin
China
HS Code
8531100000
Relay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke Detector


Introduction
 
The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the
detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard
applications such as petrochemical plants, munitions factories and other areas where flammable or explosive
liquids or solids are handled or stored. The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm


Specification
 
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: ≤10 mA @ 24 VDC
Alarm Current ≤30 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Relay Contact Load: 1A@DC24V
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady
Protection rating: IP 21
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -20°C to 55°C
Height: 45 mm installed in Base
Diameter: 103 mm
Weight: 153g

 Relay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke Detector

Installation
 
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. Mounting Indoor Wall or Ceiling Products.
1. Attach mounting base to ceiling or wall.
2. Connect field wiring to terminals:
Terminal 1: Relay Output -COM (ZONE+)
Terminal 2: Relay Output - NO/NC (ZONE-)
Terminal 3: DC Power -
Terminal 4: DC Power +
3. To attach product to mounting base.
4. Secure product by tightening the two mounting screws in the front of the product housing.
5. The detector can be connected with Security alarm panel as Figure3. Relay output signal can be changed from Normal Close (NC) to Normal Open (NO) by Jump JP1 on the PCB board.
6. The detector can be connected with conventional alarm panel as Figure 4. One 4.7K ohm resistor should be connected as End of Line (EOL) resistor at the last detector.
7. After the installation, power on the detector, use lighter or candle to test the detector within 3 meters.

WARNIING:
Not to install flame detector near the below subjects:
1. Halogen lamp, Electric discharge lamp, ultraviolet ray lamp.
2. Welding spark, Electric spark
3. Heavy current magnetic field, thunder discharge.
4. Direct sunlight.
5.Ultra violet radiation subjects
The UV flame detector can not detect the following:
1. The flame behind the glass or transparent resin.
2. Lighted cigarette.
3. Burning charcoal and coal cakes.
4. Burning material without flame.

Application in Conventional Fire Alarm system

Relay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke DetectorRelay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke Detector

Product Range


Smart Home Standalone smoke detectors and combustible/CO gas detector
4 wire smoke detectors with relay output.
2 wire smoke and heat detectors
Explosion-proof product for fire alarm system
Conventional Fire Alarm System
Addressable fire alarm system
Extinguishing control system
Wireless alarm system
Electrical fire monitor system
Fire door monitor system
Fire extinguishing Water cannon System
Industry 4 in 1 Gas detector/ Single gas detector(CO/CO2 etc)



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.

Relay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke DetectorRelay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke DetectorRelay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke DetectorRelay Output Flame Detector Alarm Detectors Fire Alarm Conventional Smoke Detector