Hfc-227ea FM-200 Total Flooding Fire Suppression System

China Hfc-227ea FM-200 Total Flooding Fire Suppression System, Find details about China Total Flooding Fire Systems, Hfc-227ea Total Flooding Fire System from Hfc-227ea FM-200 Total Flooding Fire Suppression System

Model NO.
GMQ4.2/**N-PRI
Working Temp.
0~+50degree
Trademark
PRI-SAFETY
Transport Package
by High Quality Export Packaging
Specification
90L, 120L, 150L, 180L
Origin
China
HS Code
842410
Model NO.
GMQ4.2/**N-PRI
Working Temp.
0~+50degree
Trademark
PRI-SAFETY
Transport Package
by High Quality Export Packaging
Specification
90L, 120L, 150L, 180L
Origin
China
HS Code
842410
1. Product Description 
 FM-200 / Hfc -227ea
FM-200 is an odorless, colorless, liquefied compressed gas. It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. FM-200 extinguishes a fire by a combination of chemical and physical mechanisms.
FM-200 provides excellent fire protection in a wide range of applications from sensitive electrical equipment to industrial applications using flammable liquids. FM-200 agent is used in total flooding fire suppression systems.
FM-200 does not work by displacing oxygen and is safe for use in occupied spaces without fear of oxygen deprivation.

Hfc-227ea FM-200 Total Flooding Fire Suppression System

Hfc-227ea FM-200 Total Flooding Fire Suppression System
Components of Pipe Network FM200 Fire Suppression Systems
 
1. Storage cylinder: Cylinder, container valve (with pilot valve, pressure indicator), dip tube, etc.
2. Liquid check valve: Assure one way flow of fire suppression agent, to prevent backflow.
3. High pressure hose: Connect cylinder valve and liquid check valve .
4. Safety valve: Fitted on the manifold to relieve higher pressure.
5. Selection valve: Guide fire suppression agent into different distribution pipe network.
6. Starting gas bottle: Bottle, container valve, electromagnetic drive device, pressure gauge.
7. Gas check valve: Assure one way flow of starting gas, to prevent backflow.
8. Low leakage high sealing valve: For accumulated starting gas release so to avoid malfunction of system.
9. Discharge Nozzle: Fitted at the end of pipe network to discharge fire suppressing agent.
10. Control System: Control panel, smoke and heat detector, fire alarm, discharge indicator light, etc.
Hfc-227ea FM-200 Total Flooding Fire Suppression System
Advantage
 
* Very swift fire suppression. Reach extinguishing level ≤10s.

* Safe to people. People is safe when exposed at the FM200 gas discharge level.

* Low extinguishing concentration. Nearly no obscure to vision in person evacuation.

* Easy to clean. No residue left, and minimize damage to sensitive equipment.

* Environment friendly. Zero ozone depletion potential and zero global warming potential.

* Simple installation, with small storage space.
2. Working Principle

When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto"
position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device. After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.
Hfc-227ea FM-200 Total Flooding Fire Suppression System3. Product Parameters
Item
Model
Volume x Qty
Capacity (FM200)
Working Pressure (20ºC)
Max Working Pressure (50ºC)
Activate voltage/ current
Operating Temperature Range
1
GMQ4.2/90N-PRI
90X1
≤100.8kg
4.2Mpa
5.6Mpa
DC24 V/1.2A
0ºC-50ºC
2
GMQ4.2/120N-PRI
120X1
≤134.4kg
4.2Mpa
5.6Mpa
DC24 V/1.2A
0ºC-50ºC
3
GMQ4.2/150N-PRI
150X1
≤168kg
4.2Mpa
5.6Mpa
DC24 V/1.2A
0ºC-50ºC
4
GMQ4.2/180N-PRI
180X1
≤201.6kg
4.2Mpa
5.6Mpa
DC24 V/1.2A
0ºC-50ºC
4. Work Shop
Hfc-227ea FM-200 Total Flooding Fire Suppression System
5. Product Application

MODEL ONE WITH ZONE VALVE
Hfc-227ea FM-200 Total Flooding Fire Suppression SystemMODEL TWO WITHOUT ZONE VALVE
Hfc-227ea FM-200 Total Flooding Fire Suppression System
• Bank vaults
• Libraries
• Book stores
• Electronic data processing
• Telephone exchanges
• Communication centers
 
• Transformer and switch room
• Control rooms
• Test laboratories
• Flammable liquid storage

Hfc-227ea FM-200 Total Flooding Fire Suppression System

6. Packing&Shipping
Hfc-227ea FM-200 Total Flooding Fire Suppression SystemHfc-227ea FM-200 Total Flooding Fire Suppression System
7. About Us
Hfc-227ea FM-200 Total Flooding Fire Suppression System9. Contact ways