in Row Precision Air Conditioner Made in China Modular PAC Air Cooler

in Row Precision Air Conditioner Made in China Modular PAC Air Cooler, Find details about China Air Cooler AC, Server Room Air Conditioner from in Row Precision Air Conditioner Made in China Modular PAC Air Cooler

Model NO.
in row air conditioner
Noise Level
Ordinary
Application Fields
Server Room
Mounting
in Row
Lifetime
10~15 years
Certification
RoHS, ISO, CE
Condition
New
Type of Compressor(Standard)
DC Inverter
Voltage
380/400
Frequency
50/60
Trademark
kstar
Specification
5.5kw, 7.5kw, 12.5kw, 25kw, 70kw
Origin
China
HS Code
8415812090
Model NO.
in row air conditioner
Noise Level
Ordinary
Application Fields
Server Room
Mounting
in Row
Lifetime
10~15 years
Certification
RoHS, ISO, CE
Condition
New
Type of Compressor(Standard)
DC Inverter
Voltage
380/400
Frequency
50/60
Trademark
kstar
Specification
5.5kw, 7.5kw, 12.5kw, 25kw, 70kw
Origin
China
HS Code
8415812090
In-Row Cooling Unit-FocusAir Family
With advanced cooling technology, Kstar FocusAir in-row based precision air conditioning unit has compact size and real-time temperature monitoring. It allows humidity control and precision cooling close to the server heat source for the most efficient and effective operation. It is available in three widths, 300mm, 400mm and 600mm, capacities from 25 kW to 70 kW and in system formats of air, water, glycol, chilled water and etc. Adjustable airflow baffles allow you to more precisely direct airflow within the row.   
General Features

Total cooling capacity: 25kW~70kW

FocusAir In-Row cooling system is compatible with multiple temperature sensors, monitoring the heat load change and directly control the supply air temperature, that is safe, reliable, and energy saving, making sure that the inlet air temperature of servers conform to the requirements and the equipment running in the best condition

Dimension matches the cabinet, and it supports top and bottom pipes

Inverter compressor, EC fan and electronic expansion valve are standard equipment for FocusAir series

Dynamic coordination output :The FocusAir refrigeration system works based on the change of the heat load, dynamic coordinates cooling capacity output and air volum output of the unit, realizes real-time matching with the load change to keep the unit running in the best condition

Redundant fan design: replacing the fault fan without affecting the running of FocusAir

First class components make FocusAir more stable

Dimension of FocusAir series is the same with cabinets' , so it look very beautiful

Fluorine pump can save more than 50% energy by using nature cold source
 

Technical Specification
DX Unit 
FS***unit202540
 Unit Configuration - Single CoolingConstant 
Temperature
 and Humidity
 Single Cooling Contant
 Temperature
 and Humidity
 Single CoolingConstant 
Temperature
 andHumidity
Total Cooling 
Capavity
kW25.125.540.4
Sensible Cooling
 Capavity
kW25.125.540.4
Air volumem³/h492050508080
Sensible heat ratio/111
Heating capacityKW 3 3 6
Humidyfying capacity kg/h 3 3 3
Number of
 compressors
Pcs111
Number of FansPcs633
VoltageV380~415380~415380~415
FrequencyHz505050
PhaseP333
Full-load 
 Current 
A22.727.324.829.429.438.5
Unit Weightkg230237255262305315
Unit Widthmm300400600
Unit Depthmm1100
Unit Heightmm2000
DX Unit 
FS***unit253565
 Unit Configuration - Single CoolingConstant
 Temperature
 and Humidity
 Single Cooling Contant
 Temperature
 and Humidity
 Single CoolingConstant
 Temperature
 and Humidity
Total Cooling
 Capavity
kW25.135.567
Sensible Cooling
 Capavity
kW25.135.567
Air volumem³/h5100650012000
Sensible heat
 ratio
/111
Water inlet
 Capavity
m³/h4.76.512
Pressure dropkpa455560
Heating capacityKW 3 3 6
Humidyfying capacity kg/h 3 3 3
Number of FansPcs633
VoltageV200~240380~415200~240380~415380~415
FrequencyHz505050
PhaseP13133
Full-load Current A9.322.95.318.95.314.4
Size of inlet and
 outlet water pipes
mm283242
Unit Weightkg190196215223267275
Unit Widthmm300400600
Unit Depthmm1100
Unit Heightmm2000
    Note:
               parameter table
               Air/water cooled unit data based on 37°C,25%RH indoor return air temperature.
               Chilled water unit data based on 37°C,25%RH indoor return air temperature.The intel and outlet water temperature of chilled water
 are 10°C and 15°C
               The noise data is sound pressure level value of 10m free field
               Standard outdoor unit minimum working temperature -20°C Low temperature unit minimum working temperature -40°C Standrd Unit with front air supply
               Specifications are subject to change without prior notice


in Row Precision Air Conditioner Made in China Modular PAC Air Coolerin Row Precision Air Conditioner Made in China Modular PAC Air Coolerin Row Precision Air Conditioner Made in China Modular PAC Air Coolerin Row Precision Air Conditioner Made in China Modular PAC Air Coolerin Row Precision Air Conditioner Made in China Modular PAC Air Coolerin Row Precision Air Conditioner Made in China Modular PAC Air Cooler