5A Input Clamp on Current Transformer CT for Measuring Low Current

Model NO.
GWSCCT691C
Insulating Medium
Insulating Paper
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Capacitive Type
Design Advantage
Clamp on Current Transformer
Accuracy
0.1 0.2 1.0
Split Core Transformer Input
1-200A
Split Core Transformer Output
0.333 1.5 Output
Window Size
Check Specification Below
Rated Frequency
50-400kHz
Dielectric Strength
1000mohms @ 500 VDC
Operating Temp
-25 C~+75 C
Internal Structure
Epoxy
Export Markets
Global
Trademark
grewin
Transport Package
Export Standard Cartons with Strong Pallets
Specification
CE
Origin
China
HS Code
850450000
Model NO.
GWSCCT691C
Insulating Medium
Insulating Paper
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Capacitive Type
Design Advantage
Clamp on Current Transformer
Accuracy
0.1 0.2 1.0
Split Core Transformer Input
1-200A
Split Core Transformer Output
0.333 1.5 Output
Window Size
Check Specification Below
Rated Frequency
50-400kHz
Dielectric Strength
1000mohms @ 500 VDC
Operating Temp
-25 C~+75 C
Internal Structure
Epoxy
Export Markets
Global
Trademark
grewin
Transport Package
Export Standard Cartons with Strong Pallets
Specification
CE
Origin
China
HS Code
850450000

Product Description

1.Product pictures

5A Input Clamp on Current Transformer CT for Measuring Low Current
5A Input Clamp on Current Transformer CT for Measuring Low Current

2.Features:
The structure of the self-locking, safe, easy to install, portable
Wide inner window, allowing clamping of big cables or bus-bars
Wide range of sizes to accommodate all the existing installations

3.Application:
Current measurement, monitoring and protection for electrical wiring and equipment.
Current and power measurement for electric motors, lighting, air compressor,heating and ventilation system, air-condition  equipment and automation - control system.
Current, power and energy monitoring device.

4.Specification:
Voltage grade of test circuit: 600Vac(insulated conductor) 30Vac(exposed conductor)
Medium strength: 2500V/min
Insulation resistance: 1000 M Ohms @ 500 Vdc
Operating temperature: -25ºC to +50ºC
Operating frequency: 50/60 Hz
Environmental protection: meet RoHS environmental protection requirements
Certification: meet CE requirements

5.Circuit connection diagram
5A Input Clamp on Current Transformer CT for Measuring Low Current

6.Details of the data

5A Input Clamp on Current Transformer CT for Measuring Low Current

We can produce following similar clamp on current transformer:
1.Product pictures
Clamp on Current Transformer Probe Sensor

2.specifications
Rated Primary current0.1A-1000A
Output signalmA/A or mV/A
 Maximum Non-Destructive Current2000A
Basic Accuracy1%
SafetyCAT III 600V
Dielectric Resistance1000MOhms @ 500 Vdc
Case MaterialPolypropylene resinUL flame retardant rating 94-V0
Voltage rank600Vac(isolated condition), 30Vac(bareness condition)
Maximum voltage600Vac
Useable frequency10Hz - 100kHz
Maximum Cable Diameter2.05 inches (52 mm)
 Dimensions 4.37x8.5 x1.77 in. (111x216x45 mm)
Operating Temperature-10ºC to +50ºC
StandardIEC 60044-1
AccessoriesSupplied with feet for base mounting if required
CertificationRoHS compliant CE&ETL approved

3.features(Current probe)
Good appearance
Low cost
5 standard sizes
Clamp-on core design,safer,easier installation, portable
Both Silicon Steel & Nickel Alloy cores available
Current or three specs voltage output signal 

4.applications(Current probe)
Current, power energy,monitoring devices
Power Factor Correction devices
Oscilloscope and harmonic waves analyzer

5.Details of the data
 
Part numberInput currentRated OutputFrequency
(Hz)
Secondary
Burden
Resistance
Accuracy
Class
GWCTP15350.5-1000A1mA/A40-1KHZ≤10 Ohms1%
400-1000A5A,1A50/60HZ≤2VA1%
0.1-10A100mV/A10-1000K≥100KOhms3%±10mV
0.1-100A10mV/A2%±5mV
1-1000A1mV/A1%±1mV
0.5-1000A4-20mA50/60HZ≤100 Ohms1%

6.Characteristic performance curve and size
5A Input Clamp on Current Transformer CT for Measuring Low Current

Company introduction

1.certification

We have passed ISO9001:2015,CE,SGS approval and IEC report
Low Loss Electrical Power Voltage Transformer with ISO9001: 2015
Low Loss Electrical Power Voltage Transformer with ISO9001: 2015


2.Company profile
     Tianjin Grewin is concentrating on transformers for 20 Years and complianted by ISO9001:2015,CB,IEC CB,CE etc.We're always pay great attention to its business philosophy "Quality and Honesty First".Grewin is specialized in the design and manufacture of wound components such as transformer,current sensors, chokes etc .windely used in communications,electronics,meters,industrial control,medical equipments and other fields.We are also a provider of power meters and instruments locators. 85% of its products exported to America, Europe, and Asia etc.We sincerely invite you to join us to create a bright future.

Low Loss Electrical Power Voltage Transformer with ISO9001: 2015

3.Terms of Shipment:
Within 10 working days after received related prepayment or L/C.

4.Payment terms:
(1)T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before
delivery.
(2) By irrevocable L/C at sight, to be issued immediately against confirmed order.
(3)Payment by T/T, if order amount is less than USD 20,000.
5.Production
The following picture showed you about all finished transformer production line and package with export standard carton and strong pallets:
5A Input Clamp on Current Transformer CT for Measuring Low Current


6.Flow chart of trading activities:


NO

Step

Days need

1

Request for quotation

1 day

2

Making quotations

1 day

3

Offer and counter offer

3 days

4

Sending and receiving samples

3-10 days

5

Sample confirmation

3 days

6

Placing a firm order

1 day

7

Paying and receiving the down payment

1-4 day

8

Factory production & Quality inspection

15-20 days

9

Paying and receiving the balance

4 days

10

Delivery of goods

1 days

7.contact