10kv Multi-Core XLPE Insulated Overhead Cable

China 10kv Multi-Core XLPE Insulated Overhead Cable, Find details about China Cable, ABC Cable from 10kv Multi-Core XLPE Insulated Overhead Cable

Model NO.
JKYJ JKLYJ JKLHYJ JKLGYJ
Material Shape
Round Wire
Range of Application
Refractory
Certification
ISO9001, CE, SABS
Brand
Jiapu
Standards
ASTM, IEC, DIN, CSA, BS...
Trademark
JP
Transport Package
Wooden Drums or Wooden-Steel Drums
Specification
JKYJ JKLYJ JKLHYJ JKLGYJ
Origin
China
HS Code
8544601200
Model NO.
JKYJ JKLYJ JKLHYJ JKLGYJ
Material Shape
Round Wire
Range of Application
Refractory
Certification
ISO9001, CE, SABS
Brand
Jiapu
Standards
ASTM, IEC, DIN, CSA, BS...
Trademark
JP
Transport Package
Wooden Drums or Wooden-Steel Drums
Specification
JKYJ JKLYJ JKLHYJ JKLGYJ
Origin
China
HS Code
8544601200
1, Application:
Aerial Bunched Cable ABC cable primarily used for 10kv volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75C for polyethylene insulated conductors or 90ºC for cross-linked polyethylene (XLPE) insulated conductors.

2,Specification of twisted abc cable

ABC cable meets or exceeds the following ASTM specifications:

 B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

B-231 Aluminum Conductors, Concentric-Lay-Stranded.

B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).

B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.

B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire



3,Construction of ABC cable

Conductors are concentrically stranded, compressed 1350 H-19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
 
Cross Section of Conductor 
(mm2)
Min.Nos. of Wires for Conductor
(mm)
Insulation Thickness
(mm)
Average Max. O.D.per Single-core 
(mm)
Max.Conductor Resistance at 20ºC 
(Ω/km)
Min Insulated Resistance at Rated Working Temperature
(MΩ.km)
Cable Tensile Breaking Force
  
2x1061.006.5x13.03.080.00670.671650
2x1661.208.0x16.01.910.00650.652512
2x2561.209.4x18.81.20.00540.543762
2x3561.4011.0x22.00.8680.00540.545177
2x5061.4012.3x24.60.6410.00460.467011
2x70121.4014.1x28.20.4430.0040.410354
2x95151.6016.5x33.00.320.00390.3913727
2x120151.6018.1x36.20.2520.00350.3517339
2x150151.8020.2x40.40.2060.00350.3521033
2x185302.0022.5x45.00.1640.00350.3526732
2x240302.2025.6x51.20.1250.00340.3434679
4x1061.006.5x26.03.080.00670.671650
4x1661.208.0x32.01.910.00650.652512
4x2561.209.4x37.61.20.00540.543762
4x3561.4011.0x44.00.8680.00540.545177
4x5061.4012.3x49.20.6410.00460.467011
4x70121.4014.1x56.40.4430.0040.410354
4x95151.6016.5x66.00.320.00390.3913727
4x120151.6018.1x72.40.2520.00350.3517339
4x150151.8020.2x80.80.2060.00350.3521033
4x185302.0022.5x90.00.1640.00350.3526732
4x240302.2025.6x102.40.1250.00340.3434679