Triphase 380VAC 400VAC 415VAC Online UPS for ATM and Bank System with AVR, Parallel Redundancy Function

China Triphase 380VAC 400VAC 415VAC Online UPS for ATM and Bank System with AVR, Parallel Redundancy Function, Find details about China UPS, Uninterruptible Power Supply from Triphase 380VAC 400VAC 415VAC Online UPS for ATM and Bank System with AVR, Parallel Redundancy Function

Model NO.
Queen Star Series 10K-80KVA
Output Capacity
Medium Type
Brand
Upsen or OEM
Capacity
10kVA-80kVA
Input Voltage
380VAC/220VAC
Input Frequency
50~70Hz
Support Generator Input
Yes
Wave Form
Pure Sinewave
Automatically Retransfer
Yes
Transfer Time
0ms
Display
LCD Display
Communication
RS232 Interface and Intelligent Slot
Warranty
3 Years, with 2% Free Power Circuit Boards
Trademark
UPSEN or OEM
Transport Package
Carton/Pallet
Specification
CE & ISO & ROHS Certificate
Origin
China
HS Code
8504402000
Model NO.
Queen Star Series 10K-80KVA
Output Capacity
Medium Type
Brand
Upsen or OEM
Capacity
10kVA-80kVA
Input Voltage
380VAC/220VAC
Input Frequency
50~70Hz
Support Generator Input
Yes
Wave Form
Pure Sinewave
Automatically Retransfer
Yes
Transfer Time
0ms
Display
LCD Display
Communication
RS232 Interface and Intelligent Slot
Warranty
3 Years, with 2% Free Power Circuit Boards
Trademark
UPSEN or OEM
Transport Package
Carton/Pallet
Specification
CE & ISO & ROHS Certificate
Origin
China
HS Code
8504402000

 

Model33Q10KL33Q 20KL33Q 30KL33Q 40KL33Q 60KL33Q 80KLComments
Input
Input voltage
Rated voltage380VAC/220VAC380VAC 
Phasethree phase with ground 
Input frequency
Input power factor
GeneratorSupport generator inputGenerator rating≥2*UPS rating
Input current
Rated current14A28A42A67A80A105A 
Input THDI<= 10% 
Output protection
Rating protection32A
Breaker
50A
Breaker
60A
Breaker
80A
Breaker
100A
Breaker
125A
Breaker
 
Output power
VA/watt10KVA/8KW20KVA/16KW30KVA/24KW40KVA/32KW60KVA/
48KW
80KVA/
64KW
 
Rated voltage220VAC380VACSine wave
Output frequency range
Normal mode1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode(50±0.1) Hz 
Slew rate1 Hz/Sec 
Transfer time
Normal to battery mode0mS 
Battery to normal mode0mS 
Battery and charger
Battery
Rated voltage192VDC240VDC192VDC*2192VDC*2480VDC 
Type/Rating      
Battery quantity162016*216*240 
Backup time      
Charger
Charge timeDepends on the external battery capacity 
Charge current7.5A6A5A4A10A 
Interface
Alarm silenceYES 
DC power
turn-on
YES 
Automatically retransferYES 
Communication
RS232 interfaceYES 
Intelligent slotYES 
Monitor softwareAppending with UPS 
Display
LCD/LED displays UPS status
Environment
Work temperature0ºC~40ºC 
Altitude<1000m 
Audible noise≤60dB 
Storage temperature-15ºC~45ºC 
Work humidity20%~95% 
Safety
SafetyGB4943-2001/IEC62040-1 
Outline dimension and net weight
L*W*H (mm)710*260*717840*515*1135 
Net weight(Kg)45/9350/98  195208 
*Specification is subject to change without further notice


Key Features

1. True double-conversion.
2. DSP technology guarantees high performance.
3. Output power factor 0.8.
4. Active power factor correction in all phases.
5. 50Hz/60Hz frequency converter mode.
6. Accepts dual-mains inputs.
7. Generator compatible.
8. SNMP+USB+RS-232 multiple communications.
9. 3-stage extendable charging design for optimized battery performance.
10. Adjustable battery numbers.
11. Maintenance bypass available.
12. Optional N+X parallel redundancy.

Triphase 380VAC 400VAC 415VAC Online UPS for ATM and Bank System with AVR, Parallel Redundancy Function
Triphase 380VAC 400VAC 415VAC Online UPS for ATM and Bank System with AVR, Parallel Redundancy Function

Why Choose US

Triphase 380VAC 400VAC 415VAC Online UPS for ATM and Bank System with AVR, Parallel Redundancy Function

Our Company

Triphase 380VAC 400VAC 415VAC Online UPS for ATM and Bank System with AVR, Parallel Redundancy Function


UPSEN is a professional UPS Factory since 2002, which with excellent quality and good after sales service,
Most our UPS production is done by auto machine to reduce the fault rate,our production management is authorized with ISO 9001.
Moreover, we can offer full free OEM Service !

Packing & Delivery

Triphase 380VAC 400VAC 415VAC Online UPS for ATM and Bank System with AVR, Parallel Redundancy Function


Our Service

Triphase 380VAC 400VAC 415VAC Online UPS for ATM and Bank System with AVR, Parallel Redundancy Function


FAQ

Q1. What is packing?
A: Generally, we pack our goods in neutral white boxes and brown cartons. 

If you have legally registered patent, we can pack the goods in your branded boxes after getting your authorization letters.

Q2. What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products 
And packages before you pay the balance.

Q3. What is your terms of delivery?
A: EXW, FOB, CFR, CIF, DDU.

Q4. How about your delivery time?
A: Generally, it will take 7-20 days after receiving your advance payment. 

The specific delivery time depends on the items and the quantity of your order.

Q5. Can you OEM and ODM Service?
A: Yes, we can  provide free OEM Service, and ODM Service is available for volume order too.

Q6. What is your sample policy?
A: We can supply samples for test for first time, but the customers have to pay the sample cost and the courier cost. 

And if clients can confirm a volume order after sample test, we can reduce sample cost from next order.


Q7. Do you test all your goods before delivery?
A: Yes, all our products have more than 6~8 hours for againg, and strict test before dispatch