CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination

China CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination, Find details about China Inner Cone, Connex from CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination

Model NO.
CBN35-3#
Origin
China
HS Code
8546900000
Model NO.
CBN35-3#
Origin
China
HS Code
8546900000

MV Inside Cone Plug-in Termination up to 52kV

GCA MV inside cone plug-in termination suitable for the connection between XLPE insulation power cable and the electric equipments which equipped with inside cone socket/bushing designed in accordance with EN 50180, EN 50181 and DIN 47637, such as switchgear, transformer and cable junction box etc.

CBN35-1# suit for connecting with 
size 1 socket (bushing) which is designed in accordance with EN 50180, EN 50181 and DIN 47637.
CBN35-2S# suit for connecting with size 2 socket (bushing) which is designed in accordance with EN 50180, EN 50181 and DIN 47637.
CBN35-3# suit for connecting with size 3 socket (bushing) which is designed in accordance with EN 50180, EN 50181 and DIN 47637.

Electrical specification according to standard of IEC 60502-4, IEC60840, CENELEC HD 629.1 S2.Widely used in various regions, especially fire forbidden area, high altitude, cold weather, high-humidity, salt-fog and heavy polluted regions. Reusable, easy maintenance.

 
CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination
CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination


CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination

CBN35-3#  Specification
 
EN50181 standard size GCA size Cable voltage Diameter over XLPE insulation Cable conductor size
3#, Um = 52 kV, Ir = 1250 A 3#, Um = 52 kV, Ir = 1250 A 12kV, 17.5kV, 24kV, 36kV, 40.5kV, 52kV Ø14.7~Ø53.1 mm 35~630 mm2

Application
 
CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination
CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination

                        CBN35 in cable junction box installed in Tibet railway                              CBN35 separable connector installed in transformer
           
CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination
CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination

                  CBN35 separable connector   installed in AREVA C-GIS                                            CBN35 installed in ABB switchgear
 
CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination
CBN35-3# EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV36kV 40.5kV 42kV 52kV 1250A MV Inside Cone GIS Plug-in Termination

                                 CBN35 installed in cable junction box                                                    CBN35 installed in SIEMENS switchgear