EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

China EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination, Find details about China Inner Cone, Connex from EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

Model NO.
CBN35-1#, CBN35-2S#, CBN35-3#
Type Tested
Yes
Trademark
GCA
Transport Package
Carton Box
Origin
China
HS Code
8546900000
Model NO.
CBN35-1#, CBN35-2S#, CBN35-3#
Type Tested
Yes
Trademark
GCA
Transport Package
Carton Box
Origin
China
HS Code
8546900000

MV Inside Cone Plug-in Separable Connector up to 52kV

GCA MV inside cone plug-in separable connector suitable for the connection between XLPE insulation power cable and the electric equipments which equipped with inside cone socket/bushing designed in accordance with EN 50180, EN 50181 and DIN 47637, such as switchgear, transformer and cable junction box etc.

CBN35-1# suit for connecting with 
size 1 socket (bushing) which is designed in accordance with EN 50180, EN 50181 and DIN 47637.
CBN35-2S# suit for connecting with size 2 socket (bushing) which is designed in accordance with EN 50180, EN 50181 and DIN 47637.
CBN35-3# suit for connecting with size 3 socket (bushing) which is designed in accordance with EN 50180, EN 50181 and DIN 47637.

Electrical specification according to standard of IEC 60502-4, IEC60840, CENELEC HD 629.1 S2.Widely used in various regions, especially fire forbidden area, high altitude, cold weather, high-humidity, salt-fog and heavy polluted regions. Reusable, easy maintenance.

 
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination


EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination
Specification
 
EN50181 standard size GCA size Cable voltage Diameter over XLPE insulation Cable conductor size
1#, Um = 36 kV, Ir = 630 A 1#, Um = 40.5 kV, Ir = 630 A 12kV, 17.5kV, 24kV, 36kV, 40.5kV Ø14.7~Ø34.5 mm ≤70 mm2
2#, Um = 36 kV, Ir = 800 A 2S#, Um = 40.5 kV, Ir = 800 A 12kV, 17.5kV, 24kV, 36kV, 40.5kV Ø14.7~Ø43.1 mm 35~300 mm2
3#, Um = 52 kV, Ir = 1250 A 3#, Um = 52 kV, Ir = 1250 A 12kV, 17.5kV, 24kV, 36kV, 40.5kV, 52kV Ø14.7~Ø53.1 mm 35~630 mm2


Application
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

                         CBN35 in cable junction box installed in Tibet railway                                                             CBN35 separable connector installed in transformer
           
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

                           CBN35 separable connector   installed in AREVA C-GIS                                                                    CBN35 installed in ABB switchgear

               
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination
EN50181 Inside Cone 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 40.5kV 42kV 52kV 630A 800A 1250A MV Plug-in GIS Termination

                                 CBN35 installed in cable junction box                                                                                    CBN35 installed in SIEMENS switchgear