China Factory 2kw DC to AC Battery Inverter Solar Inverter Pure Sine Wave, Find details about China 2000W Inverter, Inverter Charger from Factory 2kw DC to AC Battery Inverter Solar Inverter Pure Sine Wave
LED Model | LW500 | LW750 | LW1000 | LW1500 | LW2000 | LW2500 | LW3000 | LW4000 | LW5000 | LW6000 | LW7000 | |
LCD Model | / | / | LW1000-C | LW1500-C | LW2000-C | LW2500-C | LW3000-C | LW4000-C | LW5000-C | LW6000-C | LW7000-C | |
Nominal Power | 500W | 750W | 1000W | 1500W | 2000W | 2500W | 3000W | 4000W | 5000W | 6000W | 7000W | |
AC Input | Phase & waveform | Single Phase & Pure Sine Wave | ||||||||||
Norminal Voltage | 120VAC/230VAC OR 220/230/240VAC | |||||||||||
Acceptable Voltage | 95-126VAC OR 194-253VAC±4% | |||||||||||
Line Low Disconnect | 85V±4% OR 184±4% (154 wide mode±4%) | |||||||||||
Line Low Reconnect | 95V±4% OR 194 ±4%(164 wide mode±4%) | |||||||||||
Line High Disconnect | 136V±4%/274±4% | |||||||||||
Line High Reconnect | 126V±4%/264±4% | |||||||||||
Frequency | 50Hz(41-54) or 60Hz(51-64) (auto sensing) | |||||||||||
AC Output | Phase & Waveform | Single Phase & Pure Sine Wave (bypass mode sync to input) | ||||||||||
Voltage | 110/120/130VAC OR 220/230/240VAC±10%rms (bypass mode sync to input) | |||||||||||
Voltage Regulation | ±10%rms (bypass mode sync to input) | |||||||||||
Frequency | 50Hz±0.3Hz OR 60Hz±0.3Hz (bypass mode sync to input) | |||||||||||
Peak Power | 3 times of rating power | |||||||||||
Short Circuit Protection | Yes, shutdown after 10ms | |||||||||||
Power Factor | 0.9-1.0 | |||||||||||
DC Input | Battery Voltage | 12/24V dc | 12/24/48Vdc | 24/48Vdc | 48 | |||||||
Minimum Start Voltage | 10V for 12V, 20V for 24V, 40V for 48V | |||||||||||
Low Battery Alarm | 10.5±0.3Vdc for 12V, 21±0.6Vdc for 24V, 42V±1.2for 48V | |||||||||||
Low Battery Transfer | 10V±0.3Vdc for 12Vdc, 20V ±0.6Vdcfor 24V, 40V ±1.2Vdcfor 48V | |||||||||||
High Voltage Alarm | 16V±0.3 for 12V, 32V ±0.6for 24V, 64±1.2V for 48V | |||||||||||
High DC Input Recovery | 15.5±0.3Vdc or 31±0.6Vdc or 62V±1.2Vdc | |||||||||||
Max Charge Current | 15A20A/35A/50A/75A(According to the inverter model) | |||||||||||
Transfer Efficiency | Line Mode | >96% | ||||||||||
Battery Mode | >85% | |||||||||||
System Parameter | Power Saver | Load<=25W(Enabled on "P/S auto"setting of Remote Control | ||||||||||
Audible Alarm | Souding when the heat sink 's temperature is over 100ºCand shut down after 30 seconds | |||||||||||
Over Load Protection | 110%<Load<150%,beep 0.5s every 1s,and fault after 60s | |||||||||||
Load>150%,beeps 0.5s every 1s,and fault after 20s | ||||||||||||
Protections | low battery,over charging,over temp,over load | |||||||||||
Communications | RS-232/USB/SNMP(custom-made) | |||||||||||
Operating Environment | 0-40ºC,0-90%RH(non-condensing) | |||||||||||
Audible Noise | <60dB | |||||||||||
Net Weight(KG) | 8.5 | 8.5 | 14 | 18.5 | 18.5 | 23.6 | 23.6 | 34 | 37.5 | 46.5 | 46.5 | |
Dimension L X W X H(mm) | 380*182*160mm | 470×223×185mm | 650×223×185mm |