Item | Unit | Min | Typical | Max | Testing Condition |
Input Rated Voltage | Vdc | 19 | 27 | 29 | |
Input Current | A | 80 | |||
Input Inrush Current | A | 120 | 21V Input | ||
Input Reflected Current | 1% Input current | Rated voltage/rated load |
Item | Unit | Min | Typical | Max. | Testing Condition |
Output voltage range | Vdc | 52 | 54 | 56 | The output voltage can be regulated at 1V through 4-digit toggle switch. |
Output voltage regulation range | Vdc | 54 | 56 | 21.5V-29V Input voltage | |
Vdc | 52 | 54 | 19V-21.5V Input voltage | ||
Factory set half-load rated voltage | Vdc | 53.9 | 54 | 54.1 | 27V Input |
Output current | |||||
Voltage regulation | ±1% | ||||
Load regulation | ±0.5% | ||||
Line regulation | ±0.5% | ||||
Ripple (Vp-p) | mV | 150 | Rated input voltage/load, with 0.1uF film capacitor and 10uF high frequency electrolyte capacitor at the output, with oscilloscope band width of 20MHz. | ||
Output power | W | 1200 | Forced cooling | ||
Output efficiency | % | 85 | |||
Temperature coefficient | /ºC | ±0.02% | |||
Transient response overshoot | % | ±5 | Load variation: 25%-50%-25% or 50%-75%-50% Current variation rate: 0.1A/us Period:4ms | ||
Recovery time for transient response | μS | 200 | |||
Turn-on time | S | 3 | |||
Overshoot and undershoot @start-up/shutdown | % | ±5 | |||
Output rise-up time | ms | 5 | 50 | 200 | Rise from 10% to 90%, rated load |
Current sharing | % | ±5 |