Fast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test Kits

China Fast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test Kits, Find details about China Tp Test Kit, Syphilis Test Strip from Fast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test Kits

Model NO.
TP01
Shipment
by Air or by Sea
Specification(mm)
Strip: 2.5, 3.0; Cassette: 3.0, 4.0
Trademark
Diagnos
Transport Package
Carton
Origin
Jiangsu, China
HS Code
3822001000
Model NO.
TP01
Shipment
by Air or by Sea
Specification(mm)
Strip: 2.5, 3.0; Cassette: 3.0, 4.0
Trademark
Diagnos
Transport Package
Carton
Origin
Jiangsu, China
HS Code
3822001000
Fast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test Kits
(TP) Syphili Rapid Test Kit

Function

Rapid test for Infectious disease

Format

Strip/cassette

Specimen

serum/plasma/whole blood

Sensitivity

Over 99%

Accuracy

Over 99%

Valid

Room temperature: 24months

Buffer

Available (whole blood)

Fast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test KitsFast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test KitsFast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test Kits
Fast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test Kits

 

TEST PROCEDURE

1.  To begin testing; open the sealed pouch by tearing along the notch.. Remove the test form the pouch.

2.lay the cassette flat on a clean, dry, nonabsorbent surface ,draw about 30ul whole blood into the sample pad.

3.Then draw one drop of Sodium Chloride(about 20ul)into the sample well as well.

4.Wait for colored bands to appear.Read results within 15 minutes. Do not read results after 20 minutes

INTERPRETATION OF RESULTS

Negative: Only one pink band appears on test region of the Cassette. This indicates that there is no detectable anti-TP in the whole blood.

Positive: Two pink bands appear on test region of the Cassette. This indicates that the specimen contains detectable amount of anti-TP.

Invalid: If without colored band appears on test region, this is an indication of a possible error in performing the test. The test should be repeated using a new device.


Production Process
Fast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test Kits
Fast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test Kits
Fast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test KitsFast Delivery One Step Tp Syphilis Rapid Test Cassette / Syphilis Test Kits

FAQ

Q1.What's the method you use to do the test?

A: Colloidal Gold Method.

Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.  

Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.

Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.

Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.

Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts: 
1. Technical data: Such as the accuracy, specificity and sensitivity.
2. Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.
3. Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.
4. Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice.


 

Contact Us

Promise:We will offer our good after sale service always!as we strongly believe,QUALITY and SINCERE is very important among countries cooperations!

 

Welcome to enquiry .Pls feel free to contact us

Contact Name:Genos Dai
E-mail:sales@diagnosbio. com