1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation

China 1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation, Find details about China Vacuum Circuit Breaker, Outdoor Vacuum Circuit Breaker from 1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation

Model NO.
RVB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Tank Material
Steel
Mechanism
Spring Mechanism
Mechanical and Electrical Life
10000 Times
Pole Material
Epoxy Resin
Trademark
powertech
Transport Package
Wooden Packing
Specification
IEC, GB
Origin
Zhejiang, China
HS Code
85352100
Model NO.
RVB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Tank Material
Steel
Mechanism
Spring Mechanism
Mechanical and Electrical Life
10000 Times
Pole Material
Epoxy Resin
Trademark
powertech
Transport Package
Wooden Packing
Specification
IEC, GB
Origin
Zhejiang, China
HS Code
85352100
1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation 

General 

RVB type outdoor vacuum circuit breaker covering 12kV up to 36kV range for transformer substation and switch station using.

The current rating: 630A,....2500A, short circuit breaking current rating: 25kA,...40kA.

Its perfect design for instead of traditional type like OHB,VBF,3AF,ZW7,ZW30,ZW39,ZW37...etc.

More light, compact, relieable, and friend-enviromental.

Use of environment 
 

Ambient temperature: -40 ºC~ +85 ºC, the daily average temperature:25 ºC;

Altitude: ≤3000m(in excess of the value of technical discussions with the Division I);

Wind speed:35m/ s;

Earthquake intensity: not more than 8 degrees;

Degree of ambient air contamination level not greater than: level 3;

Daily average ambient air relative humidity ≤ 95%, on average ≤ 90%;

Saturated vapor pressure of daily mean values ≤ 2.2 × 10-3Mpa, on average ≤ 1.8 × 10-3Mpa;

More than the use of environmental conditions, please consult with the manufacturer.

Main Specification
 

No.ItemunitData
1Rated voltagekV12/24/36/40.5
2Power frequencyWet42/65/70/95
Dry45/70/80/110
Lingthning impluse withstand voltage(peak value)75/95/125/150/170/185/200
3Rated currentA630/1250A/1600/2000/2500A
4Rated short circuit breaking currentkA25/31.5/40
5Rated capacitor bank breaking currentA600/800
6Rated short circuit breaking timestimes30
7Rated making currentkA63/80/100
8Rated short circuit peak withsatnd current
9Rated shortcircuit withstand current25/31.5/40
10Rated short time duration timeS3/4
11Complete breaking timems≤100
Opening timeHighest operate voltage15~50
Rated operate voltage15~50
Lowest operate voltage30~60
Closing time25~50
12Contact closing bounce timems≤3
Out of simultaneity of contact switchingms≤2
Contact overitravel on Openingmm≤2
13Mechanical life20000(Normal)
14Electrical life(Rated onload switching)10000(Noraml)
15Rated operate sequenceO-0.3-CO-180S-CO
16Weight≤250kg


Dimension drawing      
1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation
1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation



1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation
1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation
1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation
1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation
1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation
1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation
1250A Outdoor Motorize Type Vacuum Circuit Breaker for Substation