China Switch Dr-60-24 DIN Rail Power Supply 24V 2.5A SMPS PSU, Find details about China SMPS, DIN Rail Power Supply from Switch Dr-60-24 DIN Rail Power Supply 24V 2.5A SMPS PSU
SPECIFICATIONS | ||||
OUTPUT | ||||
Model | DR-60-5 | DR-60-12 | DR-60-15 | DR-60-24 |
DC Voltage | 5V | 12V | 15V | 24V |
Rated Current | 6.5A | 4.5A | 4A | 2.5A |
Current Range | 0-6.5A | 0-4.5A | 0-4A | 0-2.5A |
Rated Power | 32.5W | 54W | 60W | 60W |
Ripple & Noise | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
Voltage Adj. Range | 4.75-5.5V | 11.1-13.2V | 13.5-16.5V | 21.6-26.4V |
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% |
Line regulation | ±1% | ±1% | ±1% | ±1% |
Load regulation | ±1% | ±1% | ±1% | ±1% |
Setup, Rise Time | 100ms,30ms/230VAC 200ms,30ms/115VAC at full load | |||
Hold Up Time | 100ms/230VAC 23ms/115VAC at full load | |||
INPUT | ||||
Voltage Range | 88~264VAC 47~63Hz; 124~370VDC | |||
AC Current | 1.2A/115V 0.8A/ 230V | |||
Efficiency | 76% | 82% | 83% | 84% |
Inrush Current | Cold start 18A/115V 36A/230V | |||
Leakage Current | <1mA/240VAC | |||
PROTECTION | ||||
Over Load | 105%~160% rated power | |||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
Over Voltage | 5.75-6.9V | 13.8-16.2V | 17.25-20.25V | 27.6-32.4V |
Protection type: Shut down o/p voltage, re-power on to recover | ||||
ENVIRONMENT | ||||
Working Temp., Humidity | -20ºC~+60ºC; 20%~90% RH non-condensing | |||
Storage Temp., Humidity | -40ºC~+85ºC; 10%~95% RH | |||
Temp. Coefficient | ±0.03%/ºC(0~50ºC) | |||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||
SAFETY | ||||
Withstand Voltage | I/P-O/P: 3KVAC | |||
Isolation Resistance | I/P-O/P: 100M Ohms / 500VDC | |||
STANDARD | ||||
Safety Standard | Design refer to UL60950-1,TUV EN60950-1,EN50178 | |||
EMC Standard | Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2,EN61204-3, heavy industrial level, criteria A | |||
OTHERS | ||||
Dimension | 78*93*56mm(W*H*D) | |||
Weight | 0.3Kg | |||
Packing | 48 pcs/carton/15.4KG/1.02CUFT | |||
NOTE | ||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |