China Rack Mounted 1000va, 2000va, 3000va, 6000va on-Line UPS, Find details about China on-Line UPS, Rack Online UPS from Rack Mounted 1000va, 2000va, 3000va, 6000va on-Line UPS
Model | EH1KR | EH1KRS | EH2KR | EH2KRS | EH3KR | EH3KRS | EH6KR | EH6KRS |
CAPACITY | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | 6000VA/4200W | ||||
INPUT | ||||||||
Phase | Single Phase with Ground | |||||||
Frequency Range | 50Hz:46~54Hz | |||||||
Power Factor | >=0.97 | >=0.98 | ||||||
Voltage Range | Base on load percentage (100%-80% / 80%-70% / 70%-60% / 60%-0%) | |||||||
Line Low Transfer | 160VAC/140VAC/120VAC/110VAC± 5VAC | 176 ±3% VAC | ||||||
Line Low Comeback | 175VAC ± 5VAC | 185 ± 3% VAC | ||||||
Line High Transfer | 300VAC± 5VAC | 276 ± 3% VAC | ||||||
Line High Comeback | 285VAC± 5VAC | 266 ± 3% VAC | ||||||
OUTPUT | ||||||||
Phase | Single | |||||||
Voltage | 220VAC/230VAC/240VAC | |||||||
Voltage Regulation | ± 2% | ± 1% | ||||||
Frequency( Synchronized Range) | 46~54Hz | |||||||
Frequency( Battery Mode) | 50 ± 0.2 Hz | 50Hz ± 0.05Hz | ||||||
Current Crest Ratio | 3:1 | |||||||
Harmonic Distortion | <= 4% THD ( Linear Load) / <= 7% THD ( Non-Linear Load) | <= 2% THD (Linear Load)/<= 6%THD(Non-Linear Load) | ||||||
Output Waveform | Pure Sinewave | |||||||
EFFICIENCY | ||||||||
To AC Mode | 85% | 85% | 85% | > 88% | ||||
To Battery Mode | 83% | 83% | 83% | > 88% | ||||
BATTERY | ||||||||
Battery Type | 12V/7Ah | Depending on the capacity of external batteries | 12V/7Ah | Depending on the capacity of external batteries | 12V/7Ah | Depending on the capacity of external batteries | 12V/7AH | Depending on the capacity of external batteries |
Numbers of Batteries | 3 | 8 | 8 | 20 | ||||
Backup Time(Full Load) | >5 minutes | >9 minutes | >5 minutes | 8 minutes | ||||
Recharge Time | 5 hours to 90% | 5 hours to 90% | 5 hours to 90% | 7 hours to 90% | ||||
Charging Current (Max.) | 1.0A | 7A | 1.0A | 8A+/-1A | 1.0A | 8A+/-1A | 2.0A | 4.2A |
Charging Voltage | 41.1Vdc ± 0.6V | 110Vdc ± 0.4V | 274Vdc ± 1%V | |||||
External Battery type | N/A | 12V/7.2AH *6 | N/A | 12V/7.2AH *8 | N/A | 12V/7.2AH *8 | N/A | 12V/7.2AH *20 |
TRANSFER TIME | ||||||||
AC to DC | Zero | |||||||
Inverter to Bypass | 2.5ms (Typical ) | Zero | ||||||
INDICATOR | ||||||||
Status | Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault | |||||||
AUDIBLE ALARM | ||||||||
Battery Mode | Sounding every 4 seconds | |||||||
Low Battery | Sounding every second | |||||||
Overload | Sounding twice every second | |||||||
Fault | Continuously Sounding | |||||||
DIMENSION | ||||||||
UPS CaseD x W H(mm) | 450x482.6x88 | 450x482.6x88 | 600x482.6x130 | |||||
Battery Case D x W x H | N/A | 450*482.6*88 | 450*482.6*88 | 600*482.6*130 | ||||
WEIGHT | ||||||||
UPS Case (kgs) | 14(w / battery) | 7 | 34.5(w / Battery) | 15 | 35.5(W / Battery) | 16 | 84(W / Battery) | 35 |
Battery Rack (kgs) | N/A | 22.5 | 27.8 | 27.8 | 64.2 | |||
ENVIRONMENT | ||||||||
Operating Environment | 0~40 Degrees Centigrade, 20~90% relative humidity (non-condensing) | |||||||
Noise Level | <45dB @ 1 Meter | 50dB @ 1 Meter | <55dB @ 1 meter | |||||
INTERFACE | ||||||||
Smart RS-232 | Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC | |||||||
SNMP (option) | Power management from SNMP manager and web browser |