China PCS1200 PLC with DI*14 DC24V, DO 10*relays, 1*RS232, 1*RS485, Find details about China PLC, Control System from PCS1200 PLC with DI*14 DC24V, DO 10*relays, 1*RS232, 1*RS485
CPU | Main parameter of electrical source | ||||
I/O | 14-CH 24VDC input 10-CH Relay output | Supply Voltage | 220VAC @50Hz | ||
Expansion capability | Up to 10 modules can be extended | Allowance range | 187~264VAC @50Hz | ||
Storage capacity | Program area : 120KB | Maximum current | 120mA | ||
N Area : 8KB M Area : 5KB | Output Voltage | 24VDC | |||
Power loss holding area : 2KB | Output Current | 400mA | |||
Timer | Hardware timing : 1, 0.1ms ~ 500ms No limit on software timing (min. 1ms) | Short-circuit protection | 800mA,24VDC output | ||
Counter | 16bit | Communication interface | 1*RS232, | ||
Operating rate | 0.06μ s(Boolean operation instruction) | 1*RS485 | |||
Interrupt input | 4 | Communication protocol | MODBUS RTU protocol, | ||
Analog potentiometer | 2 ,0~255 | Custom protocol | |||
Input Channal | Output Channal | ||||
Type of input | P/M-lesend | Type of output | Relay | ||
Input signal | Rated voltage 24VDC | Output signal | Rated voltage 24VDC or 24 ~ 230VAC | ||
0 ~ 30V DC | 5 ~30VDC or 5 ~ 250VDC | ||||
Input signal (ON) | 15~30VDC and > 3 mA | Common terminal output current summation | < 5A | ||
Input signal (OFF) | 0~5VDC and < 1mA | Output contact capacity | 2A, Impedance load | ||
Input delay | < 0.6ms (Rated input voltage) | Switch delay | < 10ms | ||
Isolation method | Optoelectronic isolation | The isolation voltage between the coil and the contact | 3000V AC, 1min, leak current 1mA | ||
Isolation of pressure | 1000VDC | Isolation voltage between contacts | 750V AC, 1min, leak current 1mA | ||
Mechanical life of relay | Without load, it can reach more than 10,000,000 times; Rated resistance 2A load, up to more than 100,000 times | ||||
Dimensions and Mounting | Work Environment | ||||
Dimensions | 120mm(L)×80mm(W)×63mm(H) | Operating temperature | 0 ~ +55ºC | ||
Weight | 380g | Storage temperature | -40 ~ +70ºC | ||
Way to install | 35mm DIN rail | Relative humnidity | 5% ~ 95% Noncondensing | ||
Panel mounting type |
Terminal | Terminal instructions | Terminal | Terminal instructions |
485+ | The positive pole of the RS485 interface | 1M | External input common terminal |
485- | The negative pole of the RS485 interface | I0.0 | Normal input terminal |
* | Undefined | I0.1 | Normal input terminal |
1L | Output common | I0.2 | Normal input terminal |
Q0.0 | Normal Output terminal | I0.3 | Normal input terminal |
Q0.1 | Normal Output terminal | I0.4 | Normal input terminal/External interrupt input |
Q0.2 | Normal Output terminal | I0.5 | Normal input terminal/External interrupt input |
Q0.3 | Normal Output terminal | I0.6 | Normal input terminal/External interrupt input |
Q0.4 | Normal Output terminal | I0.7 | Normal input terminal/External interrupt input |
2L | Output common | 2M | External input common terminal |
Q0.5 | Normal Output terminal | I1.0 | Normal input terminal |
Q0.6 | Normal Output terminal | I1.1 | Normal input terminal |
Q0.7 | Normal Output terminal | I1.2 | Normal input terminal |
Q1.0 | Normal Output terminal | I1.3 | Normal input terminal |
Q1.1 | Normal Output terminal | I1.4 | Normal input terminal |
GND | RS232 ground terminal | I1.5 | Normal input terminal |
N | Zero line | VO- | External power supply :positive |
L | Fire line | VO+ | External power supply :negative |
PIN | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
Definition | -- | RXD | TXD | -- | GND | -- | user-defined | user-defined | -- |