1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter

China 1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter, Find details about China 1200c Three-Zone Low-Vacuum CVD Furnace, Low-Vacuum CVD Furnace from 1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter

Model NO.
CY-O1200-50IIIT-3F-LV
Vacuum Tube Furnace
High Purity Quartz
Tube Diameter
50mm
Tube Length
1300mm
Heating Zone Length
300+300+300mm
Operating Temperature
0-1100c
Gas Supply System
Gas Flow Flowmeter
Measurement Accuracy
+-0.2%
Ultimate Vacuum
1.0e-1PA
Rotary Vane Pump
1.1L/S
Trademark
CYKY
Specification
Vacuum quartz tube
Origin
Zhengzhou Henan China
Model NO.
CY-O1200-50IIIT-3F-LV
Vacuum Tube Furnace
High Purity Quartz
Tube Diameter
50mm
Tube Length
1300mm
Heating Zone Length
300+300+300mm
Operating Temperature
0-1100c
Gas Supply System
Gas Flow Flowmeter
Measurement Accuracy
+-0.2%
Ultimate Vacuum
1.0e-1PA
Rotary Vane Pump
1.1L/S
Trademark
CYKY
Specification
Vacuum quartz tube
Origin
Zhengzhou Henan China
1200C three-zone low-vacuum CVD furnace with 3-channel float flow meter



Product description of vacuum CVD furnace

1200ºC three heating zone low vacuum CVD furnace with 3-channel float flow meter CY-O1200-50IIIT-3F-LV consists of a three-heating zone tube furnace, a three-channel float flow meter and a double stage rotary vane vacuum pump.

tube furnace
The three heating zones of the tube furnace on the CVD machine are independently temperature controlled by the precision temperature control instrument. By adjusting the temperature of each temperature zone, the tube furnace can form three temperature gradients in the heating zone or form a long constant temperature zone. Each zone can be edited with 30 sections of temperature rise and fall, with overheating and short circuit protection. The flanges on both sides of the furnace tube are equipped with a digital vacuum gauge and a mechanical pressure gauge, which can be used to control the atmosphere in the furnace tube. At the same time, the tube furnace is operated by high-definition true color touch screen, which is easy to use. Even non-professionals can master the use of the instrument after simple training, which can greatly improve your experiment efficiency.

float flow meter
The CVD machine is equipped with a three-channel float flowmeter, which can accurately prepare the mixed gas required for the experiment. Another pressure gauge is installed on the front of the float flowmeter to monitor the gas pressure and the mixing tank pressure.


1200ºC three heating zone low vacuum CVD furnace applications:
our CVD machine
is used by its customers to research, design, and manufacture these materials or coatings for aerospace engine components, medical implants, semiconductors, solar cells, smart glass, carbon nanotubes, nanowires, LEDs, MEMS, and other applications

Technical parameters of vacuum CVD furnace
Vacuum tube   furnaceModelCY-O1200-50IIIT
Tube materialHigh purity quartz
Tube diameter50mm (optional: 60mm, 80mm, 100mm)
Tube length1300mm
Furnace chamber   length1060mm
Heating zone   length300mm+300mm+300mm
Operating   temperature0~1100ºC
Temperature   control accuracy±1ºC
Temperature  control mode30 or 50 segment program temperature control
Display modeLCD
Sealing   method304 stainless steel vacuum flange
Flange   interface1/4" ferrule connector, KF16/25/40 joint
Vacuum4.4E-3Pa
Power supplyAC:220V   50/60Hz
Gas supply   systemModelCY-3F
Gas channel3-channel
Measuring   unitGas float flowmeter
Measuring   rangeA channel: 0~100ml H2 gasRemarks: If you need other ranges or gas types, you need to specify when ordering. According to the customer's specific requirements, the flow meter of the   corresponding gas type and range can be selected.
B channel: 16~160ml N2 gas
C channel: 25~250ml Ar gas
measurement  accuracy±2.0%
Pipe pressure resistance3MPa
Working   pressure difference50~300KPa
Connecting   pipe304 stainless steel
Gas channel304 stainless steel needle valve
Interface   specification1/4" ferrule connector for gas inlet and outlet
Exhaust   systemMechanical   pumpRotary vane pump
Pumping rate1.1L/S   
Exhaust   interfaceKF16
Vacuum   measurementResistance gauge
Ultimate   vacuum1.0E-1Pa
Power supplyAC:220V   50/60Hz
Pumping   interfaceKF16

NOTE: According to the needs of the experiment, you can choose the temperature, temperature zone, furnace size, vacuum system, flowmeter


Related photos
of vacuum CVD furnace


1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter
three-heating zone tube furnace,
1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter

three-channel float flow meter
1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter

double stage rotary vane vacuum pump

1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter
Founded in 2005, Zhengzhou CY Scientific Instrument Co., Ltd. is a company specializing in the development and production of laboratory technology research equipment. The products are mixed, pressed, burned, cut, ground, polished, coated, analytical equipment and related consumables. Products include laboratory sintering equipment, coating equipment and so on. At present, it has been exported to 25 countries and regions such as the United States, Europe, and Southeast Asia, and has been well received by various scientific research units.

We have a mature technology research and development team, the number of technicians is 33, the company has 150 people, more than 500 square meters of office space, the factory covers an area of about 1,500 square meters located in Zhengzhou High-tech Zone Electronic Industrial Park. The products are mainly located in the research market, serving scientific research in the labs of universities and colleges, and can also customize products according to your needs.

1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter

1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter
1200c Three-Zone Low-Vacuum CVD Furnace with 3-Channel Float Flow Meter

Q. Are you a manufacturer or a trading company?
A. We are professional laboratory instrument manufacturers, have their own design team and factory, have mature technical experience, and can guarantee the quality of products and the optimal price.

Q. How is your company's product after-sales service system?
A. The product warranty period is 12 months, we can provide lifetime maintenance. We have professional pre-sales and after-sales departments that can respond to you within 24 hours to resolve any technical issues.

Q. How long is your delivery time? If I want to customize the instrument, how long does it take?
A.1. If the goods are in stock, it is 5-10 days. 2. We can provide customized services for our customers. It usually takes 30-60 days depending on the specifications of the custom instrument.

Q. Our country's power supply and plug are different. How do you solve it?
A. We can supply a transformer and plug according to your local requirements according to the power plug of different countries.

Q. How to pay?
A.T / T, L / C, D / P, etc., it is recommended to use Alibaba Trade Guarantee.

Q. How is the package of goods? Delivery methods?
A.1. Standard export fumigation sign wooden box packaging 2. Express, air, sea shipping according to customer requirements, find the most suitable way.

More questions, please contact customer service