China Industrial Low Frequency on Line UPS Three Phase 100kVA, Find details about China Low Frequency UPS, Online Smart UPS from Industrial Low Frequency on Line UPS Three Phase 100kVA
Online double conversion
Full DSP control
High power factor
Wide input adaptability
Optimized battery management
N+X parallel redundancy
Strong overload capability
Power walk in
Generator mode
Multi-protection
EPO function
User-friendly network management
MODEL | EP10 | EP20 | EP30 | EP40 | EP60 | EP80 | ||
Capacity (VA/Watts) | 10kVA / 9kW | 20kVA / 18kW | 30kVA / 27kW | 40kVA / 36kW | 60kVA / 54kW | 80kVA/ 72kW | ||
INPUT | ||||||||
Operating voltage range | 380/400/415Vac (-25% / +20% ), (3Ph+N+PE) | |||||||
Operating frequency range | 50/60Hz(±5%) | |||||||
Power Factor | >0.97 (with filter) | |||||||
OUTPUT | ||||||||
Output Voltage | 380/400/415Vac (±1%) | |||||||
Output frequency | 50/60Hz (±0.05%) | |||||||
Harmonic Distortion (THDv) | <3% with linear load | |||||||
Crest factor | 3:1 (max) | |||||||
Efficiency | ≥88% | ≥89% | ≥90% | ≥90.5% | ||||
BYPASS | ||||||||
Rated voltage | 380/400/415Vac | |||||||
Rated frequency | 50/60Hz | |||||||
Voltage protection range | Upper limit: +20% (+10%,+15%,+20% adjustable)Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) | |||||||
Frequency protection range | ±10% (±2.5%, ±5%,±10%, ±20% adjustable) | |||||||
BATTERY | ||||||||
Battery voltage | 384Vdc ( 360~384Vdc ) | |||||||
SYSTEM FEATURES | ||||||||
Transfer time | 0ms (Line mode →Battery mode) | |||||||
Overload | ≤110%/60min ,≤125%/10min ,≤150%/1min,to Bypass | |||||||
LED display | Input, Inverter, Bypass, Battery, Output, Status | |||||||
LCD display | I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record | |||||||
Communication interface | Dry contact, RS232, RS485, SNMP card (Optional) | |||||||
Optional | Harmonic filter, SNMP adapter, LBS cables, battery temperature sensor,Bypass current-sharing inductor | |||||||
ENVIRONMENT | ||||||||
Operating Temperature | 0ºC~40ºC | |||||||
Storage temperature | -25~55ºC | |||||||
Humidity range | 0~95% (non-condensing) | |||||||
Altitude | <1500m | |||||||
Noise level | <60dB | <65dB | ||||||
PHYSICAL | ||||||||
Dimension W×D×H (mm) | 350×650×1050 | 430×830×1100 | 720×690×1600 | |||||
Net weight (kg) | 148 | 163 | 230 | 255 | 386 | 426 | ||
Shipping weight (kg) | 168 | 183 | 263 | 288 | 432 | 472 | ||
STANDARDS | ||||||||
Safety | IEC/EN62040-1;IEC/EN60950-1 | |||||||
Performance | IEC 62040-3 | |||||||
EMC | IEC/EN62040-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4; IEC61000-4-5;IEC61000-4-6;IEC61000-4-8;IEC 61000-4-11; |
MODEL | EP100 | EP120 | EP160 | EP200 | EP300 | EP400 | EP500 | EP600 | EP800 | ||
Capacity (VA/Watts) | 100kVA / 90kW | 120kVA / 108kW | 160kVA / 144kW | 200kVA / 180kW | 300kVA / 270kW | 400kVA/ 360kW | 500kVA/ 450kW | 600kVA/ 540kW | 800kVA/ 720kW | ||
INPUT | |||||||||||
Operating voltage range | 380/400/415Vac (-25% / +20% ), (3Ph+N+PE) | ||||||||||
Operating frequency range | 50/60Hz(±5%) | ||||||||||
Power Factor | >0.97 (with filter) | ||||||||||
OUTPUT | |||||||||||
Output Voltage | 380/400/415Vac (±1%) | ||||||||||
Output frequency | 50/60Hz (±0.05%) | ||||||||||
Harmonic Distortion (THDv) | <2% with linear load | ||||||||||
Crest factor | 3:1 (max) | ||||||||||
Efficiency | ≥92% | ≥92.5% | ≥93% | ≥93.5% | ≥94% | ||||||
BYPASS | |||||||||||
Rated voltage | 380/400/415Vac | ||||||||||
Rated frequency | 50/60Hz (auto-sensing) | ||||||||||
Voltage protection range | Upper limit: +20% (+10%,+15%,+20% adjustable)Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) | ||||||||||
Frequency protection range | ±10% (±2.5%, ±5%,±10%, ±20% adjustable) | ||||||||||
BATTERY | |||||||||||
Battery voltage | 384Vdc ( 360~408Vdc ) | 480Vdc | 600Vdc | ||||||||
SYSTEM FEATURES | |||||||||||
Transfer time | 0ms (Line mode →Battery mode) | ||||||||||
Overload | Load≤110%/60min ,≤125%/10min ,≤150%/1min,to Bypass | ||||||||||
LED display | Input, Inverter, Bypass, Battery, Output, Status | ||||||||||
LCD display | I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record, settings | ||||||||||
Communication interface | Dry contact, RS232, RS485, SNMP card (Optional) | ||||||||||
Optional | Harmonic filter, SNMP adapter, LBS cables, battery temperature sensor,Bypass current-sharing inductor | ||||||||||
ENVIRONMENT | |||||||||||
Operating Temperature | 0ºC~40ºC | ||||||||||
Storage temperature | -25~55ºC | ||||||||||
Humidity range | 0~95% (non-condensing) | ||||||||||
Altitude | <1500m | ||||||||||
Noise level | <65db | <70dB | |||||||||
PHYSICAL | |||||||||||
Dimension W×D×H (mm) | 890×775×1600(6P) 1515×830×1600(12P) | 1200×800×1600(6P) 1400×1000×1900(12P) | 1400×1000×1900(6P) 1640×1000×1900(12P) | 2580×1000×1900(500)12P 2800×1040×1900(600)12P | 3280×1040 ×1950(12P) | ||||||
Net weight (kg) | 625/1300 | 685/1450 | 1219/1774 | 1030/1715 | 1560/2395 | 1640/2510 | 3510 | 3950 | 4950 | ||
Shipping weight (kg) | 695/1370 | 755/1520 | 1349/1954 | 1130/1845 | 1690/2545 | 1770/2665 | 3730 | 4250 | 5245 | ||
STANDARDS | |||||||||||
Safety | IEC/EN62040-1;IEC/EN60950-1 | ||||||||||
Performance | IEC 62040-3 | ||||||||||
EMC | IEC/EN62040-2;IEC 61000-2-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4; IEC61000-4-5;IEC61000-4-6;IEC61000-4-8;IEC 61000-4-11; |