High Quality 10kv Surge Protection Device Circuit Breaker

China High Quality 10kv Surge Protection Device Circuit Breaker, Find details about China Engine, LED from High Quality 10kv Surge Protection Device Circuit Breaker

Model NO.
WE-AD-H1
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE
Communication Mode
Standard RS485 / Networkgprs-2g/3G/4G+RS485
Voltage
230V/400V
Current
20A~63A/80A
Frequency
50/60Hz
Product Standrad
GB10963.1,GB/T17215.211-2006, GB/T17215.322-2008,
Constant
400 Imp/Kwh
Power Lines
1 Line
Limit Breaking Capacity
6000A
Insulated Voltage Withstand
2500V/Min Tripping Time:<0.2s
Instantons Tripping Curve
Typeb, Typec, Typed
Surge Protection
6000V
Output Auxiliary Contact
5A Max(250VAC)Resistor Load
Over/Under Voltage Value
280/115V( Default Value, Configurable in Platform)
Overload Current Limit
63/80A( Default Value, Configurable in Platform)
Work/Storage Temperature
-25 ~+65 / -40 ~+75
Trademark
HonorInsight
Transport Package
Carton
Specification
126*108*104.3(mm)
Origin
Shenzhen China
HS Code
8536500000
Model NO.
WE-AD-H1
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE
Communication Mode
Standard RS485 / Networkgprs-2g/3G/4G+RS485
Voltage
230V/400V
Current
20A~63A/80A
Frequency
50/60Hz
Product Standrad
GB10963.1,GB/T17215.211-2006, GB/T17215.322-2008,
Constant
400 Imp/Kwh
Power Lines
1 Line
Limit Breaking Capacity
6000A
Insulated Voltage Withstand
2500V/Min Tripping Time:<0.2s
Instantons Tripping Curve
Typeb, Typec, Typed
Surge Protection
6000V
Output Auxiliary Contact
5A Max(250VAC)Resistor Load
Over/Under Voltage Value
280/115V( Default Value, Configurable in Platform)
Overload Current Limit
63/80A( Default Value, Configurable in Platform)
Work/Storage Temperature
-25 ~+65 / -40 ~+75
Trademark
HonorInsight
Transport Package
Carton
Specification
126*108*104.3(mm)
Origin
Shenzhen China
HS Code
8536500000
                                   High Quality 10kv Surge Protection Device Circuit Breaker
Product Description

 

1.  Brief instruction
  The device integrates smart meter, reclosed circuit breaker, and wireless collector. It can realize high-precision metering of single-phase/three-phase AC power supply circuit, and a built-in power control of various smart logics.
  • Protection functionMonitor the power consumption at the output end. In case of any abnormal situation, the power supply can be cut off quickly and automatically.
  • Automatic reclosing:Realize unattended, the circuit can be automatically reclosing after returning to normal;
  • Metering performance:High-precision real-time monitoring of voltage and current and power metering, which is conducive to energy consumption analysis on the power side;
  • Wireless communications:With local RS485 and GPRS(2G /3G) wireless communication, it can realize remote on-off control, fault inquiry and timely reporting of measurement data.
  • Equipment management:With perfect fault condition monitoring (overload, short circuit, over voltage, phase, phase imbalance) and real-time reporting and warning.
  • Electricity management:With rates in line with national standards piecewise measurement, frozen data, etc. Combined with wireless communication, it can realize remote management of electricity charge and turn off arrears.
  • Friendly display interface:With large LCD display, remote and local information exchange can be achieved. Measurement parameters and equipment status information at a glance.
  
Detailed Photos
High Quality 10kv Surge Protection Device Circuit Breaker
High Quality 10kv Surge Protection Device Circuit Breaker

 

High Quality 10kv Surge Protection Device Circuit Breaker
High Quality 10kv Surge Protection Device Circuit Breaker
 
High Quality 10kv Surge Protection Device Circuit Breaker
High Quality 10kv Surge Protection Device Circuit Breaker


 
Product Parameters

 

2. Model
   
 ModelConfiguration
1/Single phase,RS485,2G,230V
2/Three phase,RS485,2G,400V
3/Single phase,RS485,3G,230V
4/Three phase,RS485,3G,400V
 
3. Technical Data
 
Communication
Mode
Standard RS485 / NetworkGPRS-2G/3G+RS485

Power Data
Un(V)230V~/400V~3x230V~/3x400V~
Ib(A)20A20A
Imax(A)63A80A
Hz50/60Hz
Product StandardGB10963.1,GB/T17215.211-2006, GB/T17215.322-2008,
DL/T1487-2015, DL/T1485-2015, DL/T533-2007,
AccuracyActiveChass 1.0



 
 Power 
Reactive
Power
Chass 1.0
Protectionsort circuit, overload, over/under voltage, phase loss, alarm, remote
control, meter, etc
Power consumption0.5W
Constant400 imp/kWh
Power lines1 Line
Limit breaking
capacity
6000A
Insulated voltage
withstand
2500V/min Tripping time:<0.2S
Instantons tripping
curve
TypeB, TypeC, TypeD
Surge Protection6000V
Output auxiliary
contact
5A max(250VAC)resistor load
Over/under voltage
value
280/115V( default value, configurable in platform)
Overload current
limit
63/80A( default value, configurable in platform)
Electric life5000times
Mechanical life10000times
Operation timeTrip0.3s, Reclose0.8s(exclude time delay)
ConnectionDirect Connection
InstallationDIN installation of 35mm
Protection gradeIP20
Work/storage
temperature
-25°C~+65°C / -40°C~+75°C
Relative humidity95%


Unlock release
Identified the circuit fault, the electrician should pull out the safety lock and hang with a lock to solve the problem. Then, push back the safety lock, and try manually switching on the handle. If unsuccessful, electrician needs to check credit overdue or remotely switched off, by
either RS485 or GPRS.


Safety lcok
It is under operation mode while safety lock not pulled out.
It is under maintenance mode while safety lock is pulled out and needs to hang a lock. This safety lock has interlock with handle, and can't switch on, even manually, while lock pulled out. More security to
maintenance electrician.
 
Company Profile

  Guangdong Honorinsight IoT Technology Co., Ltd. is a high-tech enterprise dedicated to the R&D and industrialization promotion of key technologies of the Internet of Things and big data, and further enhance the level of intelligence of enterprises and institutions and cities. The headquarter is in Dongguan, the R&D center is in Shenzhen, the factory is in Guangzhou, and marketing and sales organizations are set up in many cities. Convergence-batch of talents with professional background from Baidu, Huawei, Tencent, Gionee, Yangzhi, Cisco, etc., in product planning, big data analysis, hardware access, UI design, mobile development, cloud architecture construction, system integration, data products and Very experienced in application and so on.


Company:
 
High Quality 10kv Surge Protection Device Circuit Breaker
High Quality 10kv Surge Protection Device Circuit Breaker
 
High Quality 10kv Surge Protection Device Circuit Breaker
High Quality 10kv Surge Protection Device Circuit Breaker