China Wholesale Medical Kidney Hemodialysis Device, Find details about China Hemodialysis Machine, Hemodialysis Device from China Wholesale Medical Kidney Hemodialysis Device
China wholesale medical kidney hemodialysis device
Description:
Dialysis machine for Toxuria/Uremia Patients blood purification.
Hemodialysis Device JHM-2028M more comprehensive features
*Combine with Hemodialysis,Hemoperfusion,ISO UF, Hemoperfusion,Plasa Exchange all-in-one *Multi-language LCD touch screen with high defintion display interface. *Air bubble monitor :optical and ultrasonic double control,can monitor blood level and accumulate air bubble
*With safe and sensitive blood leakage monitor device
*Complete water-way and electric way apart design,individual waterway control system to ensure the security
*Dialysate temperature with high precision,safety control at 35-39 centigrade *Protection from intercross infection,fluid supply loop and return loop and return loop is completely divided during disinfection to avoid polution of whole machine in the case of mis-sucking disinfection liquid
*Conductivity control and protection:conductivity A,mix,conductivity,waer outlet conductivity,insure patient's security
*Adjustable Na+curve profile,with multiplicate optional auto-adjust program,can realize indiviual dialysis and ensure patient's safety
Extracorporeal circulation system | |
Blood pump flow | 20-620ml/min |
Blood pump segment Dia. | 6.4 and 8mm adjustable |
Heparin pump flow scope | 0-10ml/h |
Syringe | 10ml/20ml/30ml;20ml/30ml/50(optional) |
Arterial and pressure monitor | `-300~+400mmHg(+-10mmHg) |
Venous Pressure monitor | `-50~+300mmHg(+-10mmHg) |
Air bubble detector | Infrared and ultrasound detection |
Dialysis System | |
Dialysis flow | 300-800ml/min linearly adjustable(+10%,-5%) |
Dialysate temperratue scope | 35.0-39.0 centigrade |
Conductivity | 12.3-15.8mS/cm |
Na+ adjustment scope | 136-145mmol/L |
HCO3-adjustment scope | 28.0-42.0mmol/L |
Bicarb Cartridge | Optional |
Blood leakage dectction | |
Method | Photoelectricity detection |
Ultrafiltration controlling system | |
Ultrafiltration ratio | 0-4000ml/h |
Pump volume accuracy | `+-1% |
Disinfection and rinse | |
Rinse and heat disinfection (above 90centigrade) | |
Chemical disinfection | Peracetic aclid |
Heat chemical disinfection | Citric acid |
Other parameter | |
Dimension | L*W*H 370mm*340mm*1450mm |
Weight | 90KG |
Power supply voltage | 100-240V Ac+-10% 50`60Hz |
Power supply voltage | 1.7KW |
Back-up battery | At least 30minutes working after cut |
Working environment | Temperature:10-30centigrade |
Relative humidity no higher than 70% | |
Water supply temperature | Great compatibility be applicable for various concentration |
Dialysate formula | ratio formula |
Pressure | 0.12-0.6Mpa |