on-Site and in Laboratory Portable Voltage Transformer Analyzer

China on-Site and in Laboratory Portable Voltage Transformer Analyzer, Find details about China Voltage Transformer Analyzer, Portable Voltage Transformer Analyzer from on-Site and in Laboratory Portable Voltage Transformer Analyzer

Model NO.
GF1061PT
Names
Laboratory Voltage Transformer Analyzer
Ratio
1-10000
Phase Error
2 Min
Ratio Error
0.02%
LCD
7 Inch Color TFT Touch LCD
Application
on-Site and in Laboratory
Test Mode
Automatic Test
Voltage Level
<=800kv
Trademark
GFUVE
Transport Package
Standard Export Wooden Box
Specification
GF1061PT 0.05%
Origin
Beijing, China
Model NO.
GF1061PT
Names
Laboratory Voltage Transformer Analyzer
Ratio
1-10000
Phase Error
2 Min
Ratio Error
0.02%
LCD
7 Inch Color TFT Touch LCD
Application
on-Site and in Laboratory
Test Mode
Automatic Test
Voltage Level
<=800kv
Trademark
GFUVE
Transport Package
Standard Export Wooden Box
Specification
GF1061PT 0.05%
Origin
Beijing, China
GF1061PT on-site and in laboratory Portable voltage transformer analyzer with printer


GF1061PT is the first portable device (4.8 kg) which offers highly accurate voltage transformer tests. This allows to use GF1061PT not only for electrical performance checks, but also for class verification and calibration. It performs quick tests of all kinds of inductive voltage transformers (VTs or PTs) and capacitive voltage transformers (CVTs) for both protection and metering purposes. Its lightweight design makes it ideal for on-site tests and calibration tasks in power system grids.

DESCRIPTION

As a manufacturer or testing lab you can use GF1061PT in your production facilities and test/development labs. it can finish the measurements (M) and protection (P) class PT. Adopt 7 inch touch TFT color LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The GF1061PT portable PT tester is the most complete and easy-to-use testing system for PTs according to IEEE and IEC standards.
The GF1061PT Transformer Analyzer measures current transformer (CT) admittance, CT ratio, CT primary-to-secondary phase angle and the voltage, current and phase angle of the service. With the 'Burden CT/PT Option', it determines the CT secondary burden capability, the regulation of the potential transformer (PT) and its secondary burden capability and provides for CT core demagnetization.
High quality CT PT analyzer for current transformer testing, AC output voltage 220V, frequency 50Hz, measurement accuracy ±0.02%, with advanced design, stable and reliable product performance, complete functions, high degree of automation and high test efficiency.

FEATURES

  • Tests of various types of measurement and protection VTs and CVTs
  • The use of advanced power technology, the test knee point reaches up to 80kV
  • No external other auxiliary equipment, stand-alone to complete all test items
  • Tests such as ratio, phase, polarity, capacitive ratio
  • PT test, easy to test, all the tests are using the same wire connection except the load test
  • It carries with thermal printer, printing test results on site
  • Parameters such as knee point current and voltage
  • Parameters such as 10% error curve, 5% error curve
  • With battery, working one week.
  • The device can store 10000 groups of test data which would not be lost if the device is power off.
  • The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word or PDF file report
  • Portability: weight 4.8kg, the best light pt analyzer
 

FUNCTION

I. Voltage transformer (PT)
1. Excitation characteristic test
2.  Transformation ratio test
3.  Polarity
4.  Ratio error, phase error
5.  Degauss
6.  Calculation of knee point value
7. Actual secondary load test (burden test)
8. Resistance test

PARAMETERS

Electrical parameters
Accuracy0.02%
Power supplyAC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage0-100Vrms
Output current0-5Arms (20A peak-value)
Output power0-400 VA (1500 VApeak)
Automatic frequency variation range0.1-60Hz
Equivalent excitation voltage≤5000V/50KV
Accuracy≤0.5%
Secondary winding DC resistance measurementRange0.1-1000Ω
Accuracy≤0.05% 
Secondary actual load measurementRange5VA-1000VA
Accuracy≤0.5%±0.1VA
PT phase error measurementAccuracy±1min (typical) / 3 min (guaranteed)
Resolution0.1min
PT ratio error measurementRange1-15000
Accuracy≤0.05%
LCD display7' inch TFT touch color LCD
Communication portUSB port
PrinterYes, Thermal printer
Standards
Reference standardsGB1207-2006, GB1208-2006, GB16847-1997 
IEC60044-1, IEC60044-6, IEC61869, ANSI/IEEE C57.13
Safety standardsGB 4793.1-2007
EMCEMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2/3/4/6
Mechanical parameters
Overall dimension (L x W x H) (mm)280 x 250 x 160 
Weight (kg)  ≤4.8
Environmental conditions
Relative humidityRelative humidity 5%-95% not condensing
Operating temperature-10°C to +50°C
Storage temperature-20°C to +70°C
Altitude≤1000m

DOWNLOAD CATALOGUE

http://www.gfuve.com/upfile/pdf/GF1061PT-Transformer-Test-GFUVE.pdf

Photo
on-Site and in Laboratory Portable Voltage Transformer Analyzer