PVDF Commercial Double Bank Aluminum Sun Shade Louvre

China PVDF Commercial Double Bank Aluminum Sun Shade Louvre, Find details about China Aluminum Sun Shade Louvre, Aluminum Louvers Facade from PVDF Commercial Double Bank Aluminum Sun Shade Louvre

Model NO.
Togen
Trademark
Togen
Specification
louver height: 1055mm
Origin
China
HS Code
73089000
Model NO.
Togen
Trademark
Togen
Specification
louver height: 1055mm
Origin
China
HS Code
73089000
 
Product Description

PVDF Commercial Double Bank Aluminum Sun Shade Louvre

Vertical Double Bank Louver VDL150-3
 

Blade Pack Depth145mm
Frame Depth150mm
Pitch75mm
Visual ImpactHidden
Free Area/

Rainwater Penetration
 
VENTILATION RATEWATER FLOW RATESEffectivenessClass
Volume
m³/s
Velocity
m/s
Supply
l/h
Penetrated
l/h
0.000.0097.20100%A
0.460.5097.20100%A
0.931.0097.20100%A
1.391.5097.20100%A
1.862.0097.20100%A
2.322.5097.20100%A
2.793.0097.20100%A
3.263.5097.20100%A

Coefficient of Entry
 
 loure face velocityair flow rate 
louver pd 
Pascals
m/stest
m³/s
theoretical
m³/s
coefficient
Ce
10.31.101.0263.8360.268
24.21.721.5965.8810.271
37.52.172.0227.3200.276
52.72.572.3958.6780.276
66.22.902.6939.7260.277
79.93.202.97310.6850.278
95.43.473.23211.6760.277
112.03.723.45912.6510.273
130.04.013.73513.6300.274
143.04.273.96914.2950.278
   mean Ce0.275
   Class3


Tested by BSRIA-EN-13030:2001PVDF Commercial Double Bank Aluminum Sun Shade Louvre

 

Design

Design
Our performance louver systems are designed using airflow simulation by CFD(computational fluid dynamics)software to get the best balance between airflow and rain defense performance
PVDF Commercial Double Bank Aluminum Sun Shade Louvre

 

Testing

Testing

Weather Louvre: UK BSRIA/US AMCA Testing

The industry standard for weather testing of Louver in the UK was developed by BSRIA(Building Services Research & Information Association) and HEVAC adopted in 2001 as a British & European Standard: BS EN 13030:2001. The principles of EN 13030 are replicated in the USA under the AMCA Standard 500-L, "Laboratory Methods of Testing Louvers for Rating"
All of our louver systems have been tested either by BSRIA or by AMCA
PVDF Commercial Double Bank Aluminum Sun Shade LouvreTwo key performance areas:
1. Rain Defence Classification
The ability to prevent rainwater from penetrating the louver
Class EffectivenessMax. allowed rain penetration l/h/m²
11 to 0.990.75
20.989 to 0.953.75
30.949 to 0.8015.00
4Below 0.80Greater than 15.00
NOTE: Water Penetration Effectiveness is measured for each of eight face velocities between 0m/s and 3.5m/s under fan-driven wind at a speed of 13m/s and water sprayed as rainfall at a rate of 75 l/h conditions.
2. Discharge Loss Coefficient Classification
A high coefficient means low resistance and high airflow performance
ClassAirflow EffectivenessPerformance Rating
10.4 to 1Excellent
20.3 to 0.399Very Good
30.2 to 0.299Good
40.199 & belowFair



 
Bird Mesh Screen

 

PVDF Commercial Double Bank Aluminum Sun Shade Louvre
Notes:
W--Width of the mesh
D--Diameter of the wire
 
Regular Size of Insect/Bird Mesh Screen(mm)
MeshWidth of the meshDiameter of the wire
Insect Mesh Screen1.5*1.50.25
2*20.5
2.5*2.50.5
Bird Mesh Screen5*50.8
10*101,1.6
11.2*11.21.6
12.5*12.51.6
PVDF Commercial Double Bank Aluminum Sun Shade Louvre
Notes:
S--SWD
L--LWD
T--Strand thickness
 
Bird Mesh Screen(Diamond)
MeshWidth of the meshStand thickness
Bird Mesh Screen(Diameter)10*201,1.5
20*401,1.5