China Low Frequency LCD Display Three Phase Pure Sine Wave UPS for Industrial Printing Machine 10-200kVA UPS System, Find details about China Low Frequency Power UPS, Three Phase 380V 400V 415VAC UPS from Low Frequency LCD Display Three Phase Pure Sine Wave UPS for Industrial Printing Machine 10-200kVA UPS System
High Efficiency Strar Series HE33 10K-200K | ||||||||||||
Model | HE33 Series UPS | |||||||||||
Capacity (VA) | 10K | 15K | 20K | 30K | 40K | 60K | 80K | 100K | 120K | 160K | 200K | |
Noninal output capacity | 8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW | 128KW | 160KW | |
Operate type | Double conversion online type | |||||||||||
Input | Nominal voltage | 220V/380, 230/400, 240/415V | ||||||||||
Voltage Tolerance | 380/400/415V±25% | |||||||||||
Frequency | 50Hz/60Hz±5% | |||||||||||
Permitted Frequency Tolerance | ±2% (selectable from ±1% to 5% from the front panel) | |||||||||||
Soft start | 0-100% in 30" (selectable) | |||||||||||
Input power factor | 0.95(with input filter) | |||||||||||
Standard features | Back Feed protection separable bypass line | |||||||||||
Phase | Three phase +N+G | |||||||||||
Output | Voltage | 220V/380, 230/400, 240/415V, ±1% (stable load), ±5%(active load) | ||||||||||
Frequency | 50/60Hz (±5%, AC mode), 50/60Hz (±1%, Battery mode) | |||||||||||
Static stability | ±5% in 19ms | |||||||||||
Distortion | Linear load <3%, non linear load<5% | |||||||||||
Power factor | 0.8 | |||||||||||
Output wave | Pure sine wave | |||||||||||
Crest factor | 3:01 | |||||||||||
Battery voltage | Standard battery voltage | 384V | 432V | 480V | ||||||||
Floating charge | 432V | 486V | 540 | |||||||||
Terminal voltage | 336V | 378V | 420V | |||||||||
Charge current | 1A-50A (Can calculate and set according to battery configuration software) | |||||||||||
Maximum Discharge Current | 28 | 42 | 56 | 85 | 113 | 169 | 225 | 282 | 338 | 381 | 507 | |
Main Function | Active voltage change | 0-100%±5% | ||||||||||
Instant recover time | <10ms | |||||||||||
Imbalance voltage | <±5%,<±1%( Balance load voltage) | |||||||||||
Overload capacity | 125%→10min,150%→1min | |||||||||||
Static switch | Automatic | |||||||||||
Protection | UPS over current, short circuit, battery low voltage, over heat | |||||||||||
Cold method | Compel aeration ( temperature control mode) | |||||||||||
Noise | 60-65dB | |||||||||||
Display | LED,LCD display | |||||||||||
Remote signalling | Voltage-free contacts | |||||||||||
Remote commands | EPO and bypass | |||||||||||
Communication Port (Optional) | double RS232 + remote contacts + 2 communication interface slots | |||||||||||
Alarm | Alarm with buzzer and indicators | |||||||||||
Environment | Temperature: 0-40C Humidity: 0-90% |