Atomic Absorption Spectrophotometer AAS with Double-beam System
Optional Agraphite Furnace & Hydride Generator
CHL-AA320N
COMMON FEATURES
- Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.
- Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
- Quickly:The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
- High precision of measurement:Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration
- High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. There- fore the light flux of double beam is enhanced.
- Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
- Multi-functionalanalysismode:formethodsofflameabsorption,flameemission,graphitefurnaceatomicabsorption and hydride generation.
- Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 0.
- Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.
STANDARD ACCESSORIES
Oil-free air compressor Glass Atomizer
Cu Hollow cathode lamp Atomizer unit
Burner unit
Dust cover Water-separating gas filter Titanium burner---10cm
OPTIONAL ACCESSORIES
Model GA3202 HGA graphite furnace system Hydride generator
Graphite tubes
Acetylene Regulator YQE-213
Software
Recirculating cooling water system
FeaturesModel | CHL-AA320N |
Wavelength Range | 190~900nm |
Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤ 0.3nm (single direction) |
Spectral Bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
Resolution | <40% |
Base Line Stability | ±0.004Abs/30min |
Characteristic Concentration | ≤ 0.04μg/ml/1% (Cu) |
Detection Limit | ≤0.008μg/ml (Cu) |
Background Calibration | >30 times |
Power Supply | 220V, 50/60Hz |
Packing Size(mm) | 1250*800*750 (Main instrument) 550*460*1350 ( Accessories ) |
Gross Weight(kg) | 150Kg (Main instrument) 50Kg ( Accessories ) |
Standard Accessories | RS232 serial port Oil-free air compressor Glass Atomizer Cu Hollow cathode lamp Atomizer unit, Burner unit ,Dust cover Water-separating gas filter Titanium burner---10cm |
Optional Accessories | Printer Model GA3202 HGA graphite furnace system Hydride generator Graphite tubes Software Recirculating cooling water system Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc) |