Neonatal Percutaneous Jaundice Meter Transcutaneous Jaundice Detector

China Neonatal Percutaneous Jaundice Meter Transcutaneous Jaundice Detector, Find details about China Percutaneous Jaundice Meter, Transcutaneous Jaundice Detector from Neonatal Percutaneous Jaundice Meter Transcutaneous Jaundice Detector

Model NO.
MCG-P06
Display
LCD
Indication Error
0~25 Mg/ Dl Add and Subtract 1.0 Mg/ Dl
Power
Lithium Battery
Check Color Screen
White End Face Is 0, The Yellow End Face 16.0+1.0
Trademark
MeCan
Transport Package
Standard Packing for Export
Origin
Guangzhou, China
Model NO.
MCG-P06
Display
LCD
Indication Error
0~25 Mg/ Dl Add and Subtract 1.0 Mg/ Dl
Power
Lithium Battery
Check Color Screen
White End Face Is 0, The Yellow End Face 16.0+1.0
Trademark
MeCan
Transport Package
Standard Packing for Export
Origin
Guangzhou, China
Neonatal Percutaneous Jaundice Meter Transcutaneous Jaundice Detector

Product Specification:
Measurementlight reflective
Light sourceLED
DisplayLCD
Indication error0 ~ 25 mg/ dL ± 1.0 mg/ dL
PowerLithium battery (DC3.6V, 1000mAh ± 20%)more than 800 times
Check color screenwhite end face is 0, the yellow end face 16.0+1.0

Main Functions:
1. Can displayed separately mg/ dL, umol/L in the meantime.
2. Data storage: can storage 200 measuring date.
3. Calculating the average function: It has the function that measuring 2-5 times, then workout the
average automatically.
4. Open Preparation time: boot, no need to prepare
5. Battery voltage detection function: it will be displayed "Low Battery" when the battery voltage less
than 3.6V.
6. Automatic shutdown after the non-working state, for 10 minutes: automatic shutdown function
7. Battery display: Top right comer of the viewing screen display different modes
it respectively means the left battery electric quantity is about 100%,75%,50%,25%,0%.
8. charging display: The viewing screen will be lighten and displayed "Charging"  during charging.
9. charging automatic protection function: It will stop charging automatically at the time battery voltage
charging arrive 4.2V±0.05V.



Product Introduction:
Jaundice is one of the most common symptoms of the neonatal period, and the Clinical Report shows that there
is 20-30% newborns may appear visibility jaundice. The pathologic jaundice for newborn may cause bilirubin
encephalopathy, thus find out the pathologic jaundice as early as possible is very important.

The clinical formerly estimate according the concentration of venous serum bilirubin. In this way, not only waste
time and vigor, but also can not be popularized because of the conditionality. What's more, it can not find out the
pathologic jaundice and doing the preventive treatment in time, may delay the best treatment time.

The DHD-D Percutaneous Jaundice Tester manufactured by our company can measuring the venous serum
bilirubin percutaneous via using optical fiber technology, photoelectric technology, electronic technique and data
processing. It only needs to use the probe of the machine touch the forehead skin of the newbor, then can
measuring the date directly and correctly.

The advantages of out machine are: can measuring without ache and without injure, with smaller size and lower
weight, easy to operate, convenient and safe use, easy to carry and easy promotion to the neonatology
department of all levels of hospital for serum bilirubin values percutaneous dynamic monitoring of the newborn.
It has the broad application prospect in the market.

Neonatal Percutaneous Jaundice Meter Transcutaneous Jaundice Detector