400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure

China 400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure, Find details about China Active Power Filter, Diesel Generator from 400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure

Model NO.
SVG-150KVAR
Electrolyte
Electrolytic
Usage
Low Frequency Coupling, Filter
Tuning
Polystyrene Capacitor
Filter
Aluminum Electrolytic Capacitor
Phase
3-Phase 4-Wire; 3-Phase 3-Wire
Compensation Current
30A~150A
Rated Voltage
AC 400/690V(± 15%)
Harmonic Filter Rate
>97%
Installation Method
Rack-Mounted or Wall-Mounted
Parallel Operation
up to 8 Modules in Parallel
Communication Board
Netherlands Philips Chips
Power Board
Korea Sanying Save Capacitor
Inverter Board
IGBT Infineon
Inductive Board
Harmonic Filter
Trademark
OEM
Transport Package
Pallet
Specification
CE ROHS
Origin
Zhejiang Yueqing
HS Code
8504409999
Model NO.
SVG-150KVAR
Electrolyte
Electrolytic
Usage
Low Frequency Coupling, Filter
Tuning
Polystyrene Capacitor
Filter
Aluminum Electrolytic Capacitor
Phase
3-Phase 4-Wire; 3-Phase 3-Wire
Compensation Current
30A~150A
Rated Voltage
AC 400/690V(± 15%)
Harmonic Filter Rate
>97%
Installation Method
Rack-Mounted or Wall-Mounted
Parallel Operation
up to 8 Modules in Parallel
Communication Board
Netherlands Philips Chips
Power Board
Korea Sanying Save Capacitor
Inverter Board
IGBT Infineon
Inductive Board
Harmonic Filter
Trademark
OEM
Transport Package
Pallet
Specification
CE ROHS
Origin
Zhejiang Yueqing
HS Code
8504409999
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure
Static Var Generator (SVG)
 also known as active power factor  compensators (APFC) or instantaneous stepless reactive power  compensators are the ultimate answer to power quality problems  caused by low power factor and reactive power demand for a wide  range of segments and applications.

They are a high performance, compact, flexible, modular and cost-effective type of active power filters (APF) that provide an instantaneous and effective  response to power quality problems in low or high voltage electric power systems.
They enable longer equipment lifetime, higher process reliability, improved power system capacity and stability, and reduced energy losses, complying with most demanding power quality standards and grid codes.

Static Var Generator

Low power factor increases the active energy losses of installations and affects their stability. It is typically caused by inductive or capacitive loads that demand extra reactive power to perform properly. Other contributors to low power factor are harmonic currents produced by nonlinear loads and the change of load in the electric power system.
SVGs deliver real-time inductive or capacitive reactive power compensation. Rapid response time provides stable and accurate power factor correction without the drawbacks of conventional solutions like capacitor banks and reactor banks.
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure

How SVG Works?

An Static Var Generator is a power electronics-based device connected in parallel with the load that requires harmonics mitigation. SVG works as a controlled current source providing any kind of current waveform in real time.
When the load generates inductive or capacitive current, it makes load current lagging or leading the voltage. An SVG detects the pase angle difference and injects in real time leading or lagging current into the electric power systems, making the phase angle of the current almost the same as that of the voltage, bringing fundamental power factor to unity. 

400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure
Typical Applications
SVGs have many low and high voltage potential applications where their use offers many benefits.
⦿ Installations with fast changing reactive power demand like electric arc furnaces and ball mills.
⦿ Highly dynamic loads where the power factor fluctuates rapidly or in big steps like cranes, sawmill machinery, welding machines, etc. 
⦿ Correction of leading power factor like in data centers allowing back-up generators operation.
⦿ UPC systems.
⦿ Solar inverters and wind turbine generators. 
⦿ Railway electrification systems: Trains & trams
⦿ Loads with low power factor: Motors, cables, lightly loaded transformers, lighting, etc. 

Elco System Static Var Generators (SVG) Benefits
Main benefits of ALBs can be summarized as: 
1. Capability to deliver instantaneous capacitive and inductive reactive power compensation.
2. Optimized for highly dynamic applications where conventional capacitor banks or reactor banks are unable to track the loads.
3. Allow compensation of loads fed by generators without risk of overcompensation. 
4. Inject reactive power that is required by the load at each instant into the system.
5. Over dimensioning not necessary: Compensation capacity equals the installed capacity.
6. Unaffected by network voltage drop. Full reactive current can be provided to meet required demand under reduced network voltage level. 
7. Simple dimensioning and installation. 
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure
400V 30kvar Static Var Generator Svg 3p3l/3p4l Power Grid Structure