off Grid Back up and Hybrid Solar Power System - Solar Inverter with MPPT Solar Charge Controller

China off Grid Back up and Hybrid Solar Power System

Model NO.
SSP3115C 1-10KW
Power Source
Solar Power
Circuit Topologies
Half-Bridge Type
Nature of Wave String
Sine Wave Inverter
Product Name
Low Frequency Solar Power Inverter
Inverter Type
Hybrid and off Grid
Input Waveform
Pure Sine Wave
with Isolation Transformer
Yes
Capacity
1-10kw
Solar Charge Controller
40A/60A MPPT
Output Priority
AC/Solar
Charging Mode
Priority
Output Voltage
120VAC(Option) 230VAC
Application
Fridge
Trademark
SOROTEC
Transport Package
Standard Exported Cartons and Pallets
Specification
CE, ISO9000
Origin
Shenzhen China
Model NO.
SSP3115C 1-10KW
Power Source
Solar Power
Circuit Topologies
Half-Bridge Type
Nature of Wave String
Sine Wave Inverter
Product Name
Low Frequency Solar Power Inverter
Inverter Type
Hybrid and off Grid
Input Waveform
Pure Sine Wave
with Isolation Transformer
Yes
Capacity
1-10kw
Solar Charge Controller
40A/60A MPPT
Output Priority
AC/Solar
Charging Mode
Priority
Output Voltage
120VAC(Option) 230VAC
Application
Fridge
Trademark
SOROTEC
Transport Package
Standard Exported Cartons and Pallets
Specification
CE, ISO9000
Origin
Shenzhen China
Off Grid Back Up and Hybrid Solar Power System - Solar Inverter with MPPT Solar Charge Controller

SOROTEC SSP3115C Series  is a Low Frequency Pure Sine Wave Solar Inverter /Hybrid and Off-Grid type DC/AC Solar Inverter special for Home and Office equipment. Its capacity from 1KW to 12KW and built-in 40A/60A MPPT solar Charge Controller.Safety and Stable Output with Isolation Transformer.can provide reliable long backup time ac power supply for home and office equipment such as:Fridge,Air-conditional,TV,Computer .etc

Key Features:
1.Built-in MPPT solar controller
2.Pure sine wave output
3.Low frequency design
4.DIP switch to set AC input voltage range and low battery trip-voltage
5.Output power factor is 0.9-1 and output socket can choose
6.Well accept generator's output and auto generator start terminal
7.Full automatical and silent operation
8.Automatically transfer between battery and line modes
9.Microprocessor control guarantees high reliability
10.Remote control,BTS function(optional)
11.Four-steps intelligent charging control to recharging time
12.Bypass function with AVR function (optional)
13.The charging current is big up to 85 Amp, can adjust through front panel
14.AC/solar output priority optional
15.Charging mode priorities optional
16.Battery type can choose through front panel
 
Full Protection:
Protection for low battery voltage,over load,output short circuit and over- temperature Restrain surge interference,eliminate noise,protection for thunder striking,provide the reliable power to the home appliances.
 
Applications:
Supply the reliable long back up time power for the home appliances and office appliances Solar power systems etc.
 
Product Descriptions Of 500Kw Solar Inverter
MODELSPS3115C 1-10KW
1kW1.5kW2kW3kW4kW5kW6kW8kW10kW
Input wave formSine wave (utility or generator)
Normal voltage120VAC(option)    230VAC
Low voltage re trip90V±4% & 184V/154V±4%
Low voltage re engage100V±4% & 194V/164V±4%
High voltage re trip140V±4% & 253V±4%
High voltage re engage135V±4% & 243V±4%
Normal input frequency50Hz/ 60Hz (auto detection)
Frequency range47Hz~65Hz
Output Wave form(Bypass mode)same as input
Over-Load ProtectionCircuit breaker
Short circuit ProtectionCircuit breaker
Efficiency on line transfer modeundefined95%
Line transfer time10ms Typical
Bypass without battery connectedYes
Inverter output
Output wave formPure sine wave
Output continuos power watts1000150020003000400050006000800010000
Surge ratings30004500600090001200015000180002400030000
Power factor0.9-1.0
Nominal Output Voltage rms120VAC(option) 230VAC
Output Voltage regulation+/- 10%rms
Output frequency50Hz ± 0.3Hz or 60Hz ± 0.3Hz
Short circuit protectionYes,fault after 1 secs
Inverter input
Nominal input voltage24V/48V48V
Minimum start voltage20V/40V40V
Low battery alarm21V/42V42V
Low battery trip20V/40V40V
High voltage alarm32V/64V64V
Charger
Output voltageDependent on battery type
Charge current10-85A MAX70A85A
Battery initial voltage for start up0-15.7v for 12v(*2 for 24v;*4 for 48v)
Over charge protection15.7v for 12v(*2 for 24v;*4 for 48v)
Solar Charger
MPPT Range@Operating Voltage30-115VDC/60-115VDC
Maximum PV Array Open Circuit Voltage145VDC
Maximum Charging Current60A
Maximum Effciency>96%
APPLICATION OF OUR PRODUCT

1. Living house and home building
2. Office building, factory and warehouse
3. Shopping mall, stadium and so on
4. Power station, field operation and some huge engineer construction
5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip 
 
COMPANY SHOW

Introduction of Company 
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.
Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards. 
 
WHY CHOOSE US ?

1, QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC. 
2, Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world. 
 
 FAQ

1. How to choose suitable inverter?
 
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
 
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
 
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power
.......................................................................................................................................................................

2. How do I choose the size of the inverter?
 
Different types of load demand for power are different. You can view the load power values to determine the 
size of the power inverter.
 
Notice:
 
Resistive load: you can choose the same power as the load. 
 
Capacitive loads: according to the load, you can choose 2-5 times power.
 
Inductive loads: according to the load, you can choose 4-7 times power.
.......................................................................................................................................................................
 
3. How connection between batteries and an power inverter?
 
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions
.......................................................................................................................................................................
 
4. How to calculate the load of working hours requires configuration of the battery size?
 
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
   Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)
.......................................................................................................................................................................