Micropette Laboratory Single-Channel Fixed Volume Mechanical Pipette

China Micropette Laboratory Single-Channel Fixed Volume Mechanical Pipette, Find details about China Adjustable Pipette, Lab Transfer Pipette from Micropette Laboratory Single-Channel Fixed Volume Mechanical Pipette

Model NO.
MicroPette
Volume Range3
20μl
Volume Range4
25μl
Volume Range5
50μl
Volume Range6
100μl
Volume Range7
200μl
Volume Range8
250μl
Volume Range9
500μl
Volume Range10
1000μl
Volume Range11
2000μl
Volume Range12
5000μl
Trademark
WESTTUNE
Transport Package
Carton
Origin
China
HS Code
9026100000
Model NO.
MicroPette
Volume Range3
20μl
Volume Range4
25μl
Volume Range5
50μl
Volume Range6
100μl
Volume Range7
200μl
Volume Range8
250μl
Volume Range9
500μl
Volume Range10
1000μl
Volume Range11
2000μl
Volume Range12
5000μl
Trademark
WESTTUNE
Transport Package
Carton
Origin
China
HS Code
9026100000
MicroPette Laboratory Single-channel Fixed Volume Mechanical Pipette
   Micropette Laboratory Single-Channel Fixed Volume Mechanical Pipette

Features for MicroPette:

•   Pipettes cover a volume range from 0.1μL to 10mL
•   Ergonomic design provides excellent operating experience
•   Large display window allows for easy volume identification
•   Easy calibration and maintenance
•   Each MicroPette supplied with an individual calibration certificate according to ISO8655


Specification:
 
Volume RangeIncrementTest Volume(μl)Accuracy errorPrecision error
   %μl%μl
5μl-5μl1.3%0.0651.2%0.06
10μl-10μl0.8%0.080.8%0.08
20μl-20μl0.6%0.120.5%0.1
25μl-25μl0.5%0.1250.3%0.075
50μl-50μl0.5%0.250.3%0.15
100μl-100μl0.5%0.50.3%0.3
200μl-200μl0.4%0.80.2%0.4
250μl--250μl0.4%1.00.2%0.5
500μl-500μl0.3%1.50.2%1.0
1000μl-1000μl0.3%3.00.2%2.0
2000μl-2000μl0.3%6.00.15%3.0
5000μl-5000μl0.3%150.15%7.5

Product details:
Micropette Laboratory Single-Channel Fixed Volume Mechanical Pipette
Micropette Laboratory Single-Channel Fixed Volume Mechanical Pipette
Micropette Laboratory Single-Channel Fixed Volume Mechanical Pipette

Pipetting Recommendations:
  
Before pipetting, make sure the pipette, tips and liquid keep at same temperature; Keep the tips connected tightly; Place the tip only a few millimeters into the liquid when aspiration; Prerinse the tip before aspirating the liquid by filling and emptying the tip 5 times. This is important especially when dispensing liquids which have a viscosity and density different from water;  Always control the push button movements with the thumb to ensure consistency; When pipetting liquids at a temperature different from ambient, prerinse the tip several times before use; Choose 30%-100% from the tip max. volume to reach accurate pipetting, the best recommendation is 50%; Hold the pipette vertically during aspiration and lean the tip on the container wall slightly when dispensing; 