Gdts Hybrid Optical and Electrical Stranded Loose Tube Cable

China Gdts Hybrid Optical and Electrical Stranded Loose Tube Cable, Find details about China Fiber, Optic from Gdts Hybrid Optical and Electrical Stranded Loose Tube Cable

Model NO.
GDTS
Trademark
FCJ OPTO TECH
Specification
SMC or Stainless steel
Origin
China
HS Code
8536700000
Model NO.
GDTS
Trademark
FCJ OPTO TECH
Specification
SMC or Stainless steel
Origin
China
HS Code
8536700000

Hybrid Optical and Electrical Stranded Loose Tube Cable (GDTS)

Single-mode/multimode Fibers are housed in loose tubes that are made of high-modulus plastic and filled with tube filling compound. In the center of cable is a metallic strength member. The tubes and copper wires (of required specifications) are stranded around the central strength member to form a cable core. The core is filled with cable filling compound and armored with corrugated steel tape. Then, a PE sheath is extruded.

Features
• Accurate process control ensuring good mechanical and temperature performances 
• Optical and electrical hybrid design, solving the problem of power supply and signal transmission and providing the centralized monitoring and maintenance of power for equipment
• Improving manageability of power and reducing coordination and maintenance of power supply
• Reducing procurement costs and saving construction costs
• Mainly used to connect BBU and RRU in DC remote power supply system for distributed base station 
• Applicable to duct and aerial installations 

Technical Characteristic
TypeO.D.
(mm)
Weight
(Kg/km)
Tensile strength
Long/short term (N)
Crush Long/short term
(N/100mm)
Structure
GDTS-02~24Xn+2×1.511.6157600/1500300/1000Structure I
GDTS-02~24Xn+2×2.512.5190600/1500300/1000Structure I
GDTS-02~24Xn+2×4.014.6241600/1500300/1000Structure II
GDTS-02~24Xn+2×5.015.0282600/1500300/1000Structure II
GDTS-02~24Xn+2×6.015.7300600/1500300/1000Structure II
GDTS-02~24Xn+2×8.016.9383600/1500300/1000StructureII
Note:
1. Xn refers to fibre type.
2. 2*1.5/2*2.5/2*4.0/2*6.0/2*8.0 indicates the number and size of copper wires.
3. Hybrid cables with different numbers and sizes of copper wires can be provided on request.
4. Hybrid cables with different fibre counts can be provided on request.

Electrical Performance of Conductor
Cross section
(mm2)
Max. DC resistance of
single conductor
(20 ºC)(Ω/km)
Insulation resistance (20ºC)(MΩ.km)Dielectric strength KV, DC 1minDielectric strength KV, DC 1min
Between each conductor and other
metal members connected in cable
Between
conductors
Between conductor
and metallic armor
Between conductor
and steel wire
1.513.3 
No less than 5,000
 
5
 
5
 
3
2.57.98
4.04.95
5.03.88
6.03.30
8.02.47
Environmental Characteristics
• Transport/storage temperature: -40ºC - +70ºC
Delivery Length
• Standard length: 2,000m; other lengths are also available.