Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace

China Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace, Find details about China Flame Aas, Aas Analysis from Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace

Model NO.
AA-4530F
Dispersive Element
Prism Spectrometer
Light Number
Polychromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Product Name
Flame Atomic Absorption Spectrometer
Usage
Determines The Presence of Metals in Liquid Sample
Applications
Biochemistry, Geology, Metallurgy
Wavelength Range
190nm-900nm
Bandwidth
0.1nm;0.2nm;0.4nm;1.0nm;2.0nm
Light
8lights
Display
LCD
Optics
Single Beam
Interface
RS232
Printer
Yes
Options
Hydride Generator
Delivery Time
in Stock
Certificate
Ce; ISO
Package
Standard Export Case
Equipped with
Computer, Software, Graphite Furnace System
Trademark
LABOAO
Transport Package
Standard Plywood Export Case
Specification
190nm-900nm
Origin
China
HS Code
9027300000
Model NO.
AA-4530F
Dispersive Element
Prism Spectrometer
Light Number
Polychromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Product Name
Flame Atomic Absorption Spectrometer
Usage
Determines The Presence of Metals in Liquid Sample
Applications
Biochemistry, Geology, Metallurgy
Wavelength Range
190nm-900nm
Bandwidth
0.1nm;0.2nm;0.4nm;1.0nm;2.0nm
Light
8lights
Display
LCD
Optics
Single Beam
Interface
RS232
Printer
Yes
Options
Hydride Generator
Delivery Time
in Stock
Certificate
Ce; ISO
Package
Standard Export Case
Equipped with
Computer, Software, Graphite Furnace System
Trademark
LABOAO
Transport Package
Standard Plywood Export Case
Specification
190nm-900nm
Origin
China
HS Code
9027300000
Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace


Automatic PC atomic absorption spectrophotometer AAS with graphite furnace

Atomic absorption spectroscopy (AAS) is a spectroanalytical procedure for the quantitative determination of chemical elements using the absorption of optical radiation (light) by free atoms in the gaseous state. Atomic absorption spectroscopy is based on absorption of light by free metallic ions.

The AA-4530F atomic absorption spectrophotometer is a single-beam instrument, equipped with a PC and dedicated programs for function controlling and data processing, for testing macro, micro and trace metal elements and semimetal elements.




Feature:
 
  1.  Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)
  2.  Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term. 
  3.  Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp
  4.  Position adjusting: the best height of the flame burner and can automatically set the front and rear positions
  5.  Fully automated wavelength scanning and peak searching
  6.  Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout
  7.  Deuterium lamp and self-absorption background regulation 
  8.  Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called
  9.  Measuring method: flame absorption method and emission method
  10.  Result printing: parameter printing, data result printing and diagram printing
Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace
 
Complete automatic controlling system 
With the help of the software, the following can be easily achieved
  1.  Selection of the element lamp
  2.  Up-down-front-rear adjustment of the lifter
  3.  Adjustment of the optical energy
  4.  Selection of the slit
  5.  Determination of wavelength scanning and peak searching
  6.  Selection of the atomizer
  7.  Setting of the background deduction method 
  8.  Controlling of the gas flow
  9.  Automatic flaming and flaming out 
  10.  Setting of the graphite furnace testing method 
Advanced graphite furnace temperature controlling technology
  1.  The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data
  2.  The fast heating capacity can improve the flexibility of the elements further 
  3.  Use the ordinary power source of 220V without need of dynamic power of 380V
  4.  The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples
  5.  Three grades adjustable gas flow can accustom to more application needs  
  6.  Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error
Safe, reliable and convenient flame system    
  1.  Epc can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily 
  2.  Efficient Atomization system enables a higher sensitivity 
  3.  The whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit tempering. Thus it keeps the operation people and equipment from harm and damage. 
Multi-functional software workstation 
  1.  A workstation that is supported WINDOWS XP/2000/NT
  2.  The rich menu brings great convenience to the use of customer
  3.  Convenient conversion between different menus makes the operation more easily
  4.  Various analytical correction methods provide the users more choices 
  5.  Basic default parameter settings enable even the beginners can do the normal operation
  6.  Flexible storage, editing and printing methods give the user largest support 
 Instrument configuration:
Atomic Absorption Spectrophotometer   1pc
Air compressor without noise            1pc 
PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)
A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)
 

Parameter:
 
Wavelength range190 - 900nm
Spectral bandwidthCan automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
Accuracy of the wavelength±0.15nm
Receptivity of the wavelength0.04nm
Base line stability0.002A/30min (Cu)
Characteristic viscosity0.02μg/ml/1% (Cu)
Checking limit0.004μg/ml (Cu)
Preciseness0.5%
Grating1800 lines/mm
In flamerAll-metal titanium burner
AtomizerEffective glass atomizer
Lamp standEight lamps
D2 background correction abilityWhen the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Size and weight700mm×550mm×450mm  75Kg
Power source220V±22V  AC

Flame system

 Acetylene air burner:100mm

 Nitrous oxide acetylene flame head:50mm

 Ignition dynamic baseline drift:≤0.006A/30min

 (Cu) Characteristic viscosity:≤0.025μg/ml/1%

 Related standard deviation of the accuracy:≤0.5%(Cu, absorbance>0.8A) (detection limit Cu0.008μg/ml)

 Safety system:Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.


Graphite furnace

 The highest temperature:3000ºC

 The largest temperature rising speed:≥2000ºC/S

 Characteristic quantity:Cd0.5×10-12g  Cu0.5×10-11g

 Accuracy:Cu3%  Cd3%

 Size and weight:550mm×450mm×300mm 65Kg

 Safety system:Over current protection

 Low air pressure alarm / protection

 Low cooling water flow alarm/protection

 Power source and power:220V±22V AC 7000W


Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace
Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace
Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace
Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace
Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace
Automatic PC Atomic Absorption Spectrophotometer Aas with Graphite Furnace