China Lung Tester Portable Digital Incentive Medical Spirometer with Mouthpiece Supply, Find details about China Ultrasound, Veterinary Ultrasound from Lung Tester Portable Digital Incentive Medical Spirometer with Mouthpiece Supply
Lung Tester Portable Digital Incentive Medical Spirometer With Mouthpiece Supply
Specifications:
1.CE approved portable spirometer can display all parameters on 5.7 320×240 dots LCD, and can store 300 copies of measurement report.
2.Soft-touch keys, easy to maintain
3.Built-in precise 110mm thermal printer
4.Small size, light weight and easy to carry
5.The spirometer can be connected to PC station through USB socket, completing a pulmonary function test directly with work station; also thousands of measurement records can be stored.
6.PC workstations support the measurement and comparison functions before and after taking medicine.
7.PC workstation support English/Chinese display and report print.
8.High-precision differential pressure flow sensor.
Features:
1.Meet the ITS, NIOSH, ERS and DIAGNOSIS standard.
2.Multi-language display and measurement report.
3.With precision flow sensor, easy to clean and sterilize, long-term durability.
4.5.7" 320*240 dots LCD, memory capacity 300 measurement records.
5.Built-in precise 110mm thermal printer.
6.Small size, light weight and easy to carry.
7.It can be connected to PC station through USB port, performing a pulmonary function test directly with PC station, also thousands of measurement records can be stored.
8.PC workstation supports the measurement and post-bronchodilator test.
9.PC workstation supports mulit-language display and report printing.
10.Support prediction equation for different races, includingITS, ECGS, KNUDSON, MORRIS/DOLGAR prediction equations.
Specifications:
Specification Items | Technique specification |
Display Screen | Diagonal line 5.7inches |
Monochrome LCD | |
Resolution 320*240 | |
Control | Standard: UTILITY KEY,SVC KEY,FVC KEY,MVV KEY,PRINT KEY,10WORDS KEY,KEY, KEY,START KEY,STOP KEY, KEY, KEY, KEY, KEY |
Light alarm | |
Measurement means | Flow velocity detection: pressure gradient pneumatic flow sensor |
Capacity detection: flow velocity integral | |
measuring range | Capacity range: 0L ~ 9L Flow velocity range: 0 ~ 14L / s |
measurement accuracy | Capacity: 0L ~ 1.6L (±50ml) 6L ~ 9L (±3%) |
Flow rate: 5% or 0.2L / s | |
Respiratory rate: 4 / 20 ~ / min (±1 / min) 20 / 60 / min (error: ± 5%) | |
measuring time limit and degree | Vital capacity: every 50s, measuring 3 FVC: per second, 25s, measuring 3 The maximum ventilation volume: every 12 seconds, measuring 3 |
Paper Recorder | Method: dot matrix |
Level Resolution Ration: 8 d/mm(speed 25mm/s) Uprightness Resolution Ration: 8 d/mm | |
Wave Channels: 1 | |
Paper Width: 110mm(1.97inches) Paper Length: 15m(100inches) | |
Formfeed Speed: 12.5,25 and 50mm/s(±2%) | |
Power supply | AC: 100V~240V DC: rechargeable Nickel-metal hydride (NI-MH), 14.4-volt, 1.8 amp hour |
Fuse | 100V~240V AC: F2A250V,5*20mm |
Safety classification | IEC60601-1 class I, type CF |
VC | Vital Capacity |
ERV | Expiratory Reserve Volume |
IRV | Inspiratory Reserve Volume |
TV | Tidal Volume |
IC | Inspiratory Capacity |
FVC | Forced Vital Capacity |
FEV0.5 | Forced Expiratory Volume in 0.5s |
FEV1.0 | Forced Expiratory Volume in 1s |
FEV3.0 | Forced Expiratory Volume in 3s |
FEV1.0%G | Forced Expiratory Volume in 1s/Forced Vital Capacity |
FEV1.0%T | Forced Expiratory Volume in 1s/Vital Capacity |
FEV3.0%G | Forced Expiratory Volume in 3s/Forced Vital Capacity |
FEV3.0%T | Forced Expiratory Volume in 3s/Vital Capacity |
Vext | Volume of Expiration |
Ex Time | Expiratory Time |
MMF | The maximum mid-expirator flow, same as MMEF |
PEF | Peak Expiratory Flow |
MEF75 | Maximum Expiratory Flow when 75% FVC remains, same as FEF25 |
MEF50 | Maximum Expiratory Flow when 50% FVC remains, same as FEF50 |
MEF25 | Maximum Expiratory Flow when 25% FVC remains, same as FEF75 |
FIVC | Forced Inspired Vital Capacity |
FIV0.5 | 0.5s Forced Inspired Volume |
FIV1.0 | 1s Forced Insipred Volume |
FIV1.0/FVC | Forced Inspired Volume in 1s/Forced Vital Capacity |
FIV1.0/FIVC | Forced Inspired Volume in 1s/Forced Inspired Vital Capacity |
PIF | Peak Inspiratory Flow |
MIF50% | Inspiratory Flow in 50% Inspired Capacity |
MVV | Maximum Voluntary Ventilation |
RR | Respiratory rate per minute |
TV | Tidal Volume in MVV measurement |
Q1. Is free sample available? |
A: Yes, sure. we are happy to send free samples of some items for quality evaluation first. Please feel free to contact us. |
Q2. What is your lead time? |
A: Normally 3-7 days in general |
Q3. How does your factory do regarding quality control? |
A: Quality is priority. All raw material we used are non-toxic, environmental-friendly. We have a professional QA/QC team to ensure the quality. And all pass the test report. |
Q4. Do you accept OEM or ODM order? |
A: Yes, sure. we accept both OEM and ODM for customers. |
Q5. What are your terms of delivery? |
A: We can accept EXW, FOB, CIF, etc. depends on which one you prefer. |
Q6. What is the payment way? |
A: TT, westeruion, ect. |