China R407c 5 Tr 10 Tr 20tr Centralized Precision Air Conditioner, Find details about China Water Cooled Precision Air Conditioner, Precision System Air Conditioner from R407c 5 Tr 10 Tr 20tr Centralized Precision Air Conditioner
small air cooled precision air conditioner | ||||||||||||||||||
model number | total/sensible cooling capacity | electric heating | air flow | air blowing way | external static pressure | cooling power input | fan motor power | noise level | water cooled condenser | humidifier | dimensions | |||||||
water cooled | air cooled | water cooled | air cooled | piping connection | water flow | water resistance | capacity | power | width | depth | height | |||||||
kw | kw | kw (grade) | m3/h | Pa | kw | kw | kw | dB(A) | m3/h | MPa | kg/h | kw | mm | mm | mm | |||
JHF5 | -- | 4.85/1.48 | 3(1) | 1420 | upside | 30 | -- | 1.8 | 0.18 | ≤51 | 4 | 3.7 | 750 | 500 | 1750 | -- | 64 | SW-3N |
downside | 30 | 1.8 | 0.18 | ≤50 | 4 | 3.7 | 750 | 500 | 1750 | 64 | ||||||||
upside(connect blast cap) | 30 | 1.8 | 0.18 | ≤50 | 4 | 3.7 | 750 | 500 | 2000 | 66.5 | ||||||||
JHF6 | -- | 6.29/5.78 | 4.5(1) | 1680 | upside | 30 | -- | 1.8 | 0.18 | ≤51.5 | 4 | 3.7 | 750 | 500 | 1750 | -- | 75 | SW-3N |
downside | 30 | 1.8 | 0.18 | ≤50.5 | 4 | 3.7 | 750 | 500 | 1750 | 75 | ||||||||
upside(connect blast cap) | 30 | 1.8 | 0.18 | 50.5 | 4 | 3.7 | 750 | 500 | 2000 | 78 | ||||||||
JHF7 | -- | 7.46/6.71 | 4.5(1) | 2200 | upside | 30 | -- | 2.7 | 0.18 | ≤53 | 4 | 3.7 | 750 | 500 | 1750 | -- | 83 | SW-3N |
downside | 30 | 2.7 | 0.18 | ≤51 | 4 | 3.7 | 750 | 500 | 1750 | 83 | ||||||||
upside(connect blast cap) | 30 | 2.7 | 0.18 | ≤51 | 4 | 3.7 | 750 | 500 | 2000 | 86.5 | ||||||||
constant temperature precision air conditioners | |||||||||||||||||||||
model number | total/sensible cooling capacity | electric heating | air flow | air blowing way | external static pressure | cooling power input | fan motor power | noise level | water cooled condenser | humidifier | dimensions | weight | outside unit | ||||||||
water cooled | air cooled | water cooled | air cooled | piping connection | water flow | water resistance | capacity | power | width | depth | height | water cooled | air cooled | ||||||||
kw | kw | kw (grade) | m3/h | Pa | kw | kw | kw | dB(A) | m3/h | MPa | kg/h | kw | mm | mm | mm | kg | kg | ||||
JH15/JHF14 | 15.3/13.6 | 13.8/12.2 | 6(2) | 4200 | upside | 60 | 4.5 | 5.0 | 1.1 | ≤57 | 1-1/4" | 3.6 | 0.065 | 4 | 3.7 | 1245 | 800 | 1950 | 420 | 400 | SW-5N |
downside | 60 | 4.5 | 5.0 | 1.1 | ≤57 | 4 | 3.7 | 1245 | 800 | 1950 | 420 | 400 | |||||||||
upside(connect blast cap) | 60 | 4.5 | 5.0 | 1.1 | ≤56 | 4 | 3.7 | 1245 | 800 | 2200 | 430 | 410 | |||||||||
JH24/JHF22 | 24.4/22.3 | 21.7/19.5 | 9(3) | 6800 | upside | 60 | 7.8 | 8.0 | 1.5 | ≤60 | 1-1/2" | 5.4 | 0.085 | 4 | 3.7 | 1920 | 840 | 1800 | 470 | 465 | SW-4N*2 |
downside | 60 | 7.8 | 8.0 | 1.5 | ≤60 | 4 | 3.7 | 1920 | 840 | 1800 | 470 | 465 | |||||||||
JH32/JHF29 | 31.5/28.3 | 28.8/25.5 | 9(3) | 8000 | upside | 60 | 9.5 | 8.0 | 2.2 | ≤62 | 1-1/2" | 7.0 | 0.065 | 4 | 3.7 | 1920 | 840 | 1800 | 491 | 485 | SW-5N*2 |
downside | 60 | 10.3 | 9.8 | 3 | ≤62 | 4 | 3.7 | 1920 | 840 | 1800 | 491 | 485 | |||||||||
JH39/JHF34 | 39.3/35.1 | 33.6/29.9 | 15(3) | 10000 | upside | 60 | 11.4 | 10.6 | 3 | ≤63 | 1-1/2" | 9.0 | 0.073 | 4 | 3.7 | 1920 | 840 | 1800 | 512 | 506 | SW-5N*3 |
downside | 60 | 12.4 | 12.4 | 4 | ≤63 | 4 | 3.7 | 1920 | 840 | 1800 | 512 | 506 | |||||||||
JH48/JHF43 | 47.5/43.3 | 42.5/38.8 | 18(3) | 12000 | downside | 70 | 14.6 | 15.9 | 3 | ≤68 | 2" | 11.0 | 0.085 | 8 | 6.1 | 2320 | 940 | 2100 | 730 | 720 | SW-5N*3 |
JH64/JHF58 | 64.4/58.3 | 57.6/52.1 | 18(3) | 15000 | downside | 70 | 20.4 | 21.9 | 4 | ≤69 | 2" | 14.5 | 0.09 | 8 | 6.1 | 2320 | 940 | 2100 | 752 | 731 | SW-10N*2 |
JH73/JHF67 | 73/66.4 | 67.2/61 | 30(3) | 17000 | downside | 70 | 22.1 | 25.1 | 4 | ≤71 | 2" | 17.7 | 0.073 | 13 | 9.8 | 2320 | 940 | 2100 | 1271 | 1040 | SW-13N*2 |
JH92/JHF85 | 92/83.2 | 85/76.5 | 36(3) | 24000 | downside | 70 | 29.2 | 31.8 | 5.5 | ≤71 | 2-1/2" | 22.0 | 0.078 | 13 | 9.8 | 2500 | 940 | 2100 | 1271 | 1040 | SW-10N*3 |
JH108/JHF102 | 108/98.5 | 102/91.8 | 36(4) | 28000 | downside | 80 | 33.5 | 37.9 | 7.5 | ≤72 | 2-1/2" | 27.5 | 0.082 | 25 | 18.75 | 2550 | 940 | 2100 | 1271 | 1040 | SW-13N*3 |
JH146/JHF135 | 146/131 | 135/122.3 | 56(5) | 34000 | downside | 80 | 44.3 | 50.3 | 11 | ≤72 | 3" | 35.5 | 0.092 | 25 | 18.75 | 4500 | 940 | 2100 | 1271 | 1040 | SW-13N*4 |
1. The temperature control range and accuracy is (18~32)±0.5ºC; | |||||||||||||||||||||
2. The humidity control range and accuracy is (40~80%)±3%; | |||||||||||||||||||||
3. The voltage is 3N~380V,50HZ. | |||||||||||||||||||||
4. The JH series are for water cooled precision units, and the JHF series are for air cooled precision units. | |||||||||||||||||||||
5. Owing to technological advances, the above specifications are subject to change without notice. |
Outside Units | ||||||
model number | SW-3N | SW-5N | SW-8N | SW-10N | SW-13N | |
motor power | KW | 0.2 | 0.28 | 0.55 | 0.75 | 1.1 |
noise level | dB(A) | 62 | 64 | 70 | 71 | 73 |
voltage | 3N~50HZ 380V | |||||
connection pipes | gas pipe | Φ15.9 | Φ19.1 | Φ19.1+Φ12.7 | Φ19.1 | Φ19.1 |
number | 1 | 1 | 1 | 2 | 2 | |
liquid pipe | Φ9.5 | Φ12.7*1 | Φ12.7+Φ9.5 | Φ12.7 | Φ12.7 | |
number | 1 | 1 | 1 | 2 | 2 | |
connection way | flare opening connected by screw thread | |||||
dimensions | width(mm) | 650 | 800 | 1000 | 1050 | 1200 |
depth(mm) | 650 | 800 | 1000 | 1050 | 1200 | |
height(mm) | 800 | 950 | 1200 | 1300 | 1300 | |
weight | kg | 76 | 105 | 176 | 203 | 280 |
No | Project Name ( China) | Industry | Area |
1 | Zhongshan people hospital | Hospital | Zhongshan |
2 | Hankou Railway Station, Union Hospital, Wuhan Branch | Hospital | Wuhan |
3 | Wuhan City, Wuchang Railway Hospital | Hospital | Wuhan |
4 | Three townships Zhongshan People's Hospital | Hospital | Zhongshan |
5 | Zhujiang hospital of Guangzhou | Hospital | Guangzhou |
6 | Zhongshan Garden Hotel | Hotel industry | Zhongshan |
7 | Western Sunshine Hotel, Zhongshan | Hotel industry | Zhongshan |
8 | Shunde Golden Hotel | Hotel industry | Foshan |
9 | East China Hotel in Guangzhou | Hotel industry | Guangzhou |
10 | Nanyou Zhuhai hotel | Hotel industry | Zhuhai |
No | Company Name ( Overseas) | Product | Country |
1 | SB Global Energy | Air cooled ducted split | Holland |
2 | Bentos pharmaceutical products Ltd. | Clean air conditioners | Nigeria |
3 | SOGAMEF | Air cooled chiller | Gabon |
4 | SeaService shipping | Marine air conditioner | Russia |
5 | EURO STANDARD LIMITED | Fresh Air Handling Unit | New Zealand |
6 | Henrich trading center | Air cooled/water cooled air conditioner | Philippines |
7 | Marine Engineering Systems Pte.Ltd | AHU, chiller,etc | Singapore |
8 | Elektro Werner Heitzinger | Heat recovery air handling unit | Austria |
9 | Nyborg Marine Equipments AS | Marine Air Handling Units | Norway |
10 | Wilfred Limited | Heat recovery air handling unit | UK |