Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat

China Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat, Find details about China Thermostat, Auto Thermostat from Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat

Model NO.
NT 35-F, NT 36-F
Max. Inrush Current
AC 16A for 10 Sec.
Casing
Plastic According to UL94 V-0, Light Grey
Dimensions
60 X 33 X 43mm
Weight
Approx. 40g
Protection Type
IP20
Trademark
Natural, OEM
Transport Package
Carton
Specification
60*33*43MM
Origin
Zhejiang, China
Model NO.
NT 35-F, NT 36-F
Max. Inrush Current
AC 16A for 10 Sec.
Casing
Plastic According to UL94 V-0, Light Grey
Dimensions
60 X 33 X 43mm
Weight
Approx. 40g
Protection Type
IP20
Trademark
Natural, OEM
Transport Package
Carton
Specification
60*33*43MM
Origin
Zhejiang, China

• Large setting range
• Small size
• Simple to mount
• High switching performance
NT 35-F, NT 35-M: Thermostat (normally closed); contact breaker for regulating heaters. The contact opens whentemperature is rising.
NT 36-F, NT 36-M: Thermostat (normally open); contact maker for regulating of filter fans and heat exchangers or forswitching signal devises when temperature limit has been exceeded. The contact closes when temperature is rising.

NT 35-F / NT 36-F, NT 35-M / NT 36-M
Switch temperature difference
+/-5°C
Sensor element
thermostatic bimetal
Contact type
snap-action contact
Service life
>100,000 cycles
Max. switching capacity
250VAC, 10 (2) A / 120VAC, 15 (2) A
DC 30W at 24VDC to 72VDC
Max. inrush current
AC 16A for 10 sec.
Connection
2-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm² (AWG 14)
stranded wire¹ 1.5mm² (AWG 16)
Mounting
clip for 35mm DIN rail, EN 60715
Casing
plastic according to UL94 V-0, light grey
Dimensions
60 x 33 x 43mm
Weight
approx. 40g
Fitting position
variable
Operating/Storage temperature
-45 to +80°C (-49 to +176°F)
Operating/Storage humidity
max. 90% RH (non-condensing)
Protection type
IP20
¹ When connecting with wires, wire end ferrules must be used.
Important note: The contact system of the regulator is subjected to environmental influences, thus the contact
resistance may change. This can lead to a voltage drop and/or self-heating of the contacts.

Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat
Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat
Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat
Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat
Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat
Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat
Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat
Natural Temperature Switches Nt 35-F, Nt 36-F Compact Thermostat